1. INSTALLATION AND USE
Mini PLUS
2
1-
1.2 SELF-TEST
Printer operating status is indicated in the configuration print-out in which, next to the name of the components
displayed (see figure 1.2), the following information is given:
• under
HEAD TEMPERATURE
is given the temperature of the head.
• under
HEAD VOLTAGE
is given the voltage of the head.
1.3 CONFIGURATION
This printer permits the configuration of default parameters. The printer’s configurable parameters are:
•
Baud Rate:
38400, 19200
D
, 9600, 4800, 2400,1200, 600.
•
Data length:
7, 8
D
bits/car.
•
Parity:
None
D
, Even or Odd.
•
Handshaking:
XON/XOFF
D
or Hardware.
•
Autofeed:
CR disabled
D
or CR enabled.
•
Columns:
24 col.
D
, 40 col.
•
Print Mode:
Normal
D
or Reverse.
•
Char Mode:
Normal
D
, Double width (2 x Width), Double height (2 x Height),
Expanded.
•
Print density:
-2, -1, 0
D
, +1, +2.
Please note: the parameters marked with the symbol
D
represent the default values.
The settings made are stored in nonvolatile memory and are loaded automatically .
During power-up, if the FEED key
(1)
is held down, the printer enters the autotest routine and prints out the
setup report. The printer will remain in standby in Hexadecimal dump mode (see section 1.4) until another key
is pressed or characters are received through the printer communication port.
When the FEED key
(1)
is pressed, the printer enters parameter configuration. Each time the FEED key
(1)
is
pressed, the parameter will change and the current value will be printed out. Once the desired value has been
attained, hold the FEED key
(1)
down for at least a second to pass to the next parameter, and so on. Printing
out of a new printer set up report indicates that set up is complete.
NOTE
(1)
:
The FEED key is external and must be connected to serial connector as indicated in
paragraph 2.1.
(Fig.1.2)
* PRINTER SETUP *
HEAD TEMPERATURE [
°
C]= 32.5
HEAD VOLTAGE [V]
= 5,0
Baud Rate
: 38400 bps
Data length
: 8 bits/chr
Parity
: None
Handshaking
: Xon/Xoff
Autofeed
: CR disabled
Columns
: 24 col.
Print Mode
: Normal
Chars Mode
: Normal
Print Density
: 0
[PUSH]
ENTER SET-UP
[FAST PUSH]
EXIT
Содержание Mini PLUS
Страница 1: ...Mini PLUS Ultra Small Thermal Panel Printer Mini PLUS User Manual www custom it ...
Страница 9: ...INTRODUCTION Mini PLUS 4 Blank page ...
Страница 15: ...1 INSTALLATION AND USE Mini PLUS 6 1 Blank page ...
Страница 31: ...3 PRINTER FUNCTIONS Mini PLUS 3 14 Blank page ...
Страница 35: ...4 TECHNICAL SPECIFICATIONS Mini PLUS 4 4 Blank page ...