A - 3
APPENDIX A
Read all of this manual to become thoroughly familiar with this vehicle. Pay particular attention to all Notices, Cautions, Warnings, and Dangers.
Troubleshooting Instructions
If a fault occurs, count the number of red flashes between pauses and refer to the table below:
Red Flashes
Cause
Solution
Charge Enable Fault or
Check connector contacts and retry.
Battery Temperature Fault
Check that battery temperature is between
-10°C and +50°C.
Battery Voltage Too Low or High
Check battery size and condition of
batteries.
Charge Timeout caused by battery
pack not reaching required voltage.
Check for loose connections or corrosion.
Charger output was reduced due to
high temperatures.
Operate charger at a lower ambient
temperature or increase cooling air flow.
Check Battery: battery could not be
trickle charged up to minimum voltage
Check for shorted or damaged cells.
Over-Temperature: Charger shut
down due to high internal
temperature.
Ensure sufficient cooling air flow and reset
charger (interrupt AC power for 15
seconds).
Charger Internal Fault
Reset charger (interrupt AC power for 15
seconds). Return to qualified service depot
if fault persists.
Specifications
DC Output – see Operating Instructions
QuiQ Model:
912-2400
628089
912-3600-07
628102
912-4800-14
624206
Voltage-nom (V)
24
36
48
Voltage-max (V)
34
51
67
Current-max (A)
25
21
18
Battery Type
Lead acid (Wet / AGM / GEL)
Reverse Polarity
Electronic protection auto-reset
Short Circuit
Electronic current limit
AC Input
All models
Voltage-max (Vrms)
85 265
Frequency (Hz)
45 - 65
Current - max (Arms)
9.5A @ 120VAC
5A @ 230VAC
AC Power Factor
>0.99 at 120VAC
>0.98 at 230VAC
Mechanical
All models
Dimensions
28.0 x 24.5 x 11.0 cm (11 x 9.7 x
4.3)
Weight
<5 kg (11 lbs)
Environmental
Enclosure: IP66
Operating
Temperature
-30°C to +50°C (-22°F to 122°F),
derated above 30°C, below 0°C
Storage Temperature
-40°C to +70°C (-40°F to 158°F)
AC input connector
IEC320/C14
(require 1.8m localized cord)
DC output
OEM specific w/ 12AWG wire
Operation
All models
w/Default Algo 1
Battery Temperature
Compensation
Automatic
Maintenance Mode
Auto-restart if V < 2.08V/cell
or 30 days elapse
Regulatory
Safety
EN 60335-2-29
Safety of Appliances/ Battery Chargers
UL2202 (1
st
Ed.)
EV Charging System Equipment
UL1564 3rd Ed.
Industrial Battery Charger
CSA- 107.2
Battery Chargers- Industrial
Emissions
FCC Part 15/ICES
003
Unintentional Radiators Class A
EN 55011
Radio disturbance characteristics
(Class A)
EN 61000-3-2
Limits for harmonic current emissions
EN 61000-3-3
Limits of voltage fluctuations and
flicker
Immunity
EN 61000-4-2
Electrostatic discharge immunity
EN 61000-4-3
Radiated, radio-frequency,
EMF immunity
EN 61000-4-4
Electrical fast transient/burst immunity
EN 61000-4-5
Surge immunity
EN 61000-4-6
Conducted Immunity
EN 61000-4-11
Voltage variations immunity
Product warranty is dependent on model - please contact dealer of original equipment for warranty service.
Note: This is a Class A product. In a domestic environment this product may cause radio interference, and the user may be required to take adequate measures.
2012 © Delta-Q Technologies Corp. All rights reserved. PN: 710-0141 Rev 1