Ⅵ、
Door station setting order
CODE
ORDER
DIGIT CODE
Significance
remark
*000
XXXX
The manager operates the lock
**00
XXXX
(4 passwords)
Confirmating the manager
password
It should be confirm the manager password first
before using the order from **00 to **19
(Tacitly approves No, is 2098)
**01
XXXX
(4 new passwords)
Revising the manager password
**02
000X
Revising the coding method
the efficient number are 1.2.3.6.7.8.9.0
”0” is the onmipotent coding (Tacitly approves
No, is 2)
**03
0XXX
Revising the ringing time
001-255seconds(Tacitly approves No, is 60)
**04
0XXX
Revising the Dialogue time
001-255seconds(Tacitly approves No, is 120)
**05
000X
Revising the ring types
0-9(0 is the “dingdong” sound, and 1-9 is the
phone sound) (Tacitly approves No, is 0)
**06
0XXX
Revising the waiting time after
ringing
001-255seconds(the user also can answer the
phone after the ring stopped) (Tacitly approves
No, is 1)
**07
0XXX
Revising the time of operating
lock
001-255seconds(unit is 0.2 second, tacitly
approves No, is 5,namely the time of unlocking
is 1 second)
**08
0XXX
Revising the waiting time after
opening the door
001-255seconds(the talking time after opening
the door) (Tacitly approves No, is 20)
**09
000X
demonstration type at standby
state
0-9 (Tacitly approves No, is 1)(0-off,1-9 are
demostrating)
**10
000X
Controlling thecode tube to
demonstrate or to slake when
picking up phone
0-1(Tacitly approves No, is 1)
0 is to slake
1 is to demonstrate
**11
0XXX
revising the alarm time
000-255seconds,000-close the alarm function.
(Tacitly approves No, is 000)
**12
0XXX(Serial
number)
XXXX(password)
Manager revising the unlock
password of users
The scope of Serial number:000-239
password cancelling:0000
**13
XXXX XXXX
establishing eight public
password to open locks
password cancelling:0000
**15
YXXX(module
address)
edits comparative table of "
onmipotent coding "
Reference the comparative table of " onmipotent
coding "
**16
000X
choosing the " dialing digit"
Only suit for the onmipotent coding the
effective number is 1.2.3.4,(Tacitly approves
No, is 3)
**17
000X
Which digit to demonstrate a
letter
The effective digit is 1-4,or the tacitly approves
demonstrate no letter
**18
XXXX(room No.)
Checking the room number of
onmipotent coding
Checking the module address of the room
number in table “onmipotent coding”
**19
Restoring factory setting
Restoring the digits **02-**11,**16-**17 are
the factory tacitly approves No,
Содержание CS-200BV-1
Страница 1: ...www cusamintercom com 0 CODING INTERCOM USER S MANUAL ...
Страница 4: ...www cusamintercom com 3 Indoor phones ...
Страница 16: ...www cusamintercom com 15 Ⅴ System schematic and wiring diagram 1 System structure schematic drawing ...
Страница 17: ...www cusamintercom com 16 2 System wiring diagram ...
Страница 18: ...www cusamintercom com 17 ...