If the number call managing center is 999,then do as follows:

**00 2098

**15 when it comes with Y011,then input“001”

After it comes with FFFF or another four figures,then please input“0999”

1

1

1

1

5

5

5

5

...

.

Address

Address

Address

Address

setting

setting

setting

setting

instruction

instruction

instruction

instruction

1

Network module

Set address as JP6

it is effective only when the short-

circuit block is inserted

The number you set must be the same with floor

number

2

Audio and Video Switcher

Set address as JP4

it is effective only when

the short-circuit block is inserted

don’t do anything on S w 4

keep the contact

pin open circuit

)。

The number is building number reduce one

3

Network Switcher

the scope is 0-31

it is effective only when the short-

circuit block is inserted

Scale setting

the scope is 1-2

it is effective only when

the short-circuit block is inserted

Wrong

Wrong

Wrong

Wrong

code

code

code

code

Significance

Significance

Significance

Significance

Wrong

Wrong

Wrong

Wrong

code

code

code

code

Significance

Significance

Significance

Significance

E01

overtime

E07

The extension phone or the main line

open circuit

E02

Wrong order

E08

The extension phone or the main line

short-circuit

E03

Wrong password

E09

Scope mistake of module address

when coding in onmipotent coding

E04

Data-in over scope

E10

The repetition of room number when

coding in onmipotent coding

E05

Wrong room number

E11

Can’t find the room number in table

onmipotent coding

E06

Forbidden call

FXXX

Input wrong password three times and

keyboard is locked

Содержание CS-12V

Страница 1: ...INTERCOM INTERCOM SYSTEM SYSTEM SYSTEM FOR FOR FOR APARTMENT APARTMENT APARTMENT NETWORK NETWORK NETWORK USER USER USER S S S MAUAL MAUAL MAUAL QUZHOU QUZHOU QUZHOU ZHUOCHENG ZHUOCHENG ZHUOCHENG ELEC...

Страница 2: ...initializating room number and extension phone address the 1st kind 9 7 Table3 3 comparative table of initializating room number and extension phone address the 2nd kind 10 8 Table3 4 comparative tab...

Страница 3: ...www cusamintercom com 2...

Страница 4: ...ndoor phones phones phones input door station and indoor phone number the corresponding indoor phone ring and user can talk with managing center Door Door Door station station station call call call m...

Страница 5: ...System 3 System 3 System schematic schematic schematic and and and W W Wiring iring iring diagram diagram diagram 1 1 1 System System System structure structure structure schematic schematic schemati...

Страница 6: ...g wiring diagram diagram diagram Wiring Wiring Wiring Instruction Instruction Instruction Managing center to Audio and Video Switcher Vi GV VG GGV Audio GT Audio GG Audio and Video Swithcher to Door s...

Страница 7: ...you want to change press if you don t say only check it then it will show the next address that s need to be set If the three figures you input have existed in the table that s say repetiton then it...

Страница 8: ...k Door Door Door Station Station Station number number number and and and the the the first first first address address address Door Door Door Station Station Station No No No 001 001 001 032 032 032...

Страница 9: ...ame with door station number setting The address of Network Module can be 127 04 at most If you want to code 100 01 or above address please enter from 99 04 and add by press and code when it comes to...

Страница 10: ...ension extension extension phone phone phone address the address the address the 1 1 1st st st kind kind kind Module address coding site Room No Module address codin g site Room No Module address codi...

Страница 11: ...1201 Y10 3 2001 Y14 3 2801 Y02 4 0402 Y06 4 1202 Y10 4 2002 Y14 4 2802 Y03 1 0501 Y07 1 1301 Y11 1 2101 Y15 1 2901 Y03 2 0502 Y07 2 1302 Y11 2 2102 Y15 2 2902 Y03 3 0601 Y07 3 1401 Y11 3 2201 Y15 3 30...

Страница 12: ...to be set If you input 0000 means you don t use this address Quick Quick Quick setting setting setting If the coding method of indoor phones corresponds with rule of table 3 2 Then door station provid...

Страница 13: ...want is 19 the block of short circuit should be inserted in 1 2 16 place You can get other module address according this method Coding site 01 04 connect with JP1 F01 JP2 F02 JP3 F03 JP4 F04 The compa...

Страница 14: ...001 255 seconds Tacitly approves is 120 05 000X Choosing ringing type 0 9 0 is Dingdong sound 1 9 are phone sound Tacitly approves is 0 06 0XXX Revising waiting time after ringing 001 255 seconds the...

Страница 15: ...11 16 17 are the factory tacitly approves No 21 000X Network or not 0 Non network tacity approve 1 Network Order Order Order Order Order Order code code code Following Following Following code code co...

Страница 16: ...ve only when the short circuit block is inserted don t do anything on Sw4 keep the contact pin open circuit The number is building number reduce one 3 Network Switcher the scope is 0 31 it is effectiv...

Страница 17: ...r It will show A J in digit tube and correspond with figure 1 9 0 Managing center will change letter into figure All room number must be figure 15 Edit comparative table of room number Reference the c...

Страница 18: ...Table2 2 Table2 2 Wrong Wrong Wrong code code code form form form of of of managing managing managing center center center Wrong Wrong Wrong code code code Significance Significance Significance Wrong...

Страница 19: ...rm alarm alarm 1 1 1 each each each room room room uses uses uses one 2 one 2 one 2 two two two rooms rooms rooms use use use one one one 4 4 4 four four four rooms rooms rooms use use use one one one...

Страница 20: ...r 42 42 42 XX XX XX XX XX XX Previse Previse Previse the the the second second second room room room comparative comparative comparative table table table 49 49 49 XX XX XX XX XX XX Previst Previst Pr...

Страница 21: ...een Between Between Network Network Network Switcher Switcher Switcher 485bus 485bus 485bus Under Under Under 500m 500m 500m 0 3mm 0 3mm 0 3mm2 2 2 500 1000m 500 1000m 500 1000m 0 5mm 0 5mm 0 5mm2 2 2...

Страница 22: ...cher and Audio Video Switcher should use UPS seperately 2 The balance point of managing center and door station is affected by the lenth of cable So you must re adjust the balance Potentiometers 3 Whe...

Отзывы: