Network Essentials IOS-XE Image Features:  

Layer 2 switching: 

o

 

IEEE 802.1, 802.3 standard, NTP, UDLD, CDP, LLDP, unicast MAC filter, VTPv2, 
VTPv3, EtherChannel, voice VLAN, PVST+, MSTP, and RSTP 

Layer 3 Routing 

o

 

Static IP routing (for dynamic routing, see Network Advantage option) 

Multicast: 

o

 

IGMPv1, v2, v3 snooping, IGMP filtering, IGMP querier 

Management: 

o

 

Web UI, MIB, SmartPort, SNMP, syslog, DHCP server, SPAN session, Full Flexible 
Netflow (FnF) 

Precision Timing: 

o

 

IEEE-1588v2 Precision Timing Protocol (PTP): hardware time-stamping supported on 
1GBaseT ports for real time clock synchronization of devices with sub-microsecond 
accuracy (transparent / boundary clock) 

Security: 

o

 

Port security, Access Control Lists (ACLs), 802.1x, Dynamic Host Configuration 
Protocol (DHCP) snooping, DHCP-port based allocation, dynamic ARP inspection, IP 
source guard, guest VLAN. MAC authentication bypass, 802.1x multi-domain 
authentication, storm control - unicast, multicast, broadcast, SCP, SSH, SNMPv3, 
, RADIUS server/client, MAC address notification, BPDU guard, RMON, 
MACsec-128 

Layer 2 Line-rate Encryption and Information Assurance (IA): 

o

 

IEEE 802.1AE MACsec support on 1GBaseT ports for point-to-point authentication 
and encryption of Ethernet LAN traffic 

o

 

MACsec supports key exchange from switch-to-switch or switch-to-end-points using 
SAP/MKA protocols 

o

 

Cisco ESS-3300 on NSA Commercial Systems for Classified (CSfC) MACSec 
Ethernet Encryption Device list and National Information Assurance Partnership 
(NIAP) Common Criteria Evaluation and Validation Scheme (CCEVS) List 

Declassification: 

o

 

Data zeroization support to erase nonvolatile Flash memory and return device to 
factory default configuration (initiated via discrete input) 

Quality of Service (QoS): 

o

 

Ingress policing, rate limit, egress queuing/shaping, autoQoS 

Layer 2 IPv6: 

o

 

IPv6 host support, HTTP over IPv6, SNMP over IPv6 

 

 

Network Advantage IOS-XE License Features:  

o

 

All features supported in Network Essential IOS-XE License, plus: 

o

 

Dynamic routing protocol support: 

 

Open Shortest Path First (OSPF), v2, v3, v4 and v6 

 

Enhanced Interior Gateway Routing Protocol (EIGRP), v4 and v6 

 

Routing Information Protocol (RIP), v1 and v2 

Содержание DuraNET 3300

Страница 1: ...24x 1000BASE T w PoE and 2x 10GBASE SR USER MANUAL DuraNET 3300 Rugged Cisco ESS 3300 L2 L3 Ethernet Switch ...

Страница 2: ...prietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Curtiss Wright Contact Information Curtiss Wright Defense Solutions Division 3222 S Washington St Salt Lake City Utah USA 84115 T 1 801 483 1533 Toll Free 1 800 483 3152 F 1 801 483 1523 Email Sal...

Страница 3: ...s 14 Cable Install and Connections 15 Accessing the CLI through the Console Port 16 Software Terminal Emulator and Serial Console Setup 16 Linux 16 Windows 18 Execute and Configure the PuTTY installer 18 Running PuTTY 21 Setting an Open Firewall Port 29 USB Console Port 31 Linux 31 Windows 32 RS 232 Console Port 32 Recommended Settings 33 Chapter 3 Connector Descriptions 34 Connector Identificatio...

Страница 4: ...tions 66 Vertical Mounting 66 Horizontal Mounting 67 Grounding 68 Power 69 Environmental Specifications 69 Temperature 69 Shock Vibration 69 EMI EMC Compliance 69 Operating Conditions 70 Cisco Specifications 70 Other Specifications 74 Reliability 74 Export Jurisdiction 74 Regulatory Compliance 74 Warranty 74 Chapter 6 Troubleshooting 75 Product Identification 75 Technical Assistance 75 Returning f...

Страница 5: ...re 3 7 J4 Pin Arrangement 47 Figure 4 1 Show Configuration Listing 50 Figure 4 2 Show Boot Listing 50 Figure 4 3 Update APT package repository cache 51 Figure 4 4 Install the tftpd hpa package 51 Figure 4 5 tftpd hpa package installed 52 Figure 4 6 Check whether the tftpd hpa service is running 52 Figure 4 7 tftpd hpa is running 53 Figure 4 8 Modify the etc default tftpd hpa configuration file 53 ...

Страница 6: ... J2 Connector Pinout By Pin Number 38 Table 3 11 J2 Connector Pinout By Function 40 Table 3 12 J3 EAU Connector Information 42 Table 3 13 J3 Production Connector Information 42 Table 3 14 J3 Connector Pinout By Pin Number 42 Table 3 15 J3 Connector Pinout By Function 45 Table 3 16 J4 Connector Information 47 Table 3 17 J4 Connector Pinout 47 Revision History Table REVISION HISTORY Rev Date Page s ...

Страница 7: ...and includes procedures for starting the system and usage of the zeroization capabilities Chapter 5 provides chassis specifications dimensions and mounting instructions In addition it provides the technical and environmental specifications for the DuraNET 3300 Chapter 6 provides troubleshooting instructions and technical support contact information Chapter 7 provides additional contact information...

Страница 8: ... in Cisco s ESS 3300 IOS managed Gigabit and 10 Gigabit Ethernet connectivity for a devices installed at the tactical network edge on board unmanned air ground vehicles UAVs UGVs helicopters fixed wing aircraft tactical ground vehicles and other SWaP constrained platforms deploying Ethernet backbones With Cisco Network Essentials switching or Network Advantage software switching routing software l...

Страница 9: ...ediate System to Intermediate System IS IS Protocol Independent Multicast PIM Rugged MIL STD Design MIL STD 810G and DO 160G environmental qualifications shock vibration thermal altitude humidity ingress Filtered transient and EMI protected MIL STD 1275 704 DO 160 compliant power supply for aircraft and vehicle dirty power input support for PoE injected IP phones and cameras 50ms power hold up opt...

Страница 10: ...xternal connector coatings EAU system and cable set configurations include Table 1 1 EAU System Configurations Product Number Description NET 3300 01H E DuraNET 3300 Ethernet Switch 24 x 1000BASE T with 50 ms switch holdup Network Essentials IOS EAU NET 3300 02 E DuraNET 3300 Ethernet Switch 24 x 1000BASE T 2 x 10GBASE SR Network Essentials IOS EAU NET 3300 11 E DuraNET 3300 Ethernet Switch 24 x 1...

Страница 11: ... x 10GBASE SR with 50 ms switch holdup Network Essentials IOS NET 3300 11 DuraNET 3300 Ethernet Switch 24 x 1000BASE T Network Advantage IOS NET 3300 11H DuraNET 3300 Ethernet Switch 24 x 1000BASE T with 50 ms switch holdup Network Advantage IOS NET 3300 12 DuraNET 3300 Ethernet Switch 24 x 1000BASE T 2 x 10GBASE SR Network Advantage IOS NET 3300 12H DuraNET 3300 Ethernet Switch 24 x 1000BASE T 2 ...

Страница 12: ...User Manual DuraNET 3300 Introduction Page 12 of 84 MNL 0676 01 Rev A4 ECO N A Effective 26 Feb 21 Architecture Block Diagram Figure 1 1 DuraNET 3300 Architecture Block Diagram ...

Страница 13: ...t the relationship between cables cable port labels and Cisco port definitions Table 2 1 DuraNET 3300 Breakout Cables Cisco Ports and Port Labels J2 CBL 2884 01 J3 CBL 2885 01 Cisco Port Cable Label Cisco Port Cable Label Cisco Port Cable Label Gi1 3 P3 Gi2 1 P11 Gi2 9 P19 Gi1 4 P4 Gi2 2 P12 Gi2 10 P20 Gi1 5 P1 Gi2 3 P9 Gi2 11 P17 Gi1 6 P2 Gi2 4 P10 Gi2 12 P18 Gi1 7 P7 Gi2 5 P15 Gi2 13 P23 Gi1 8 P...

Страница 14: ...igabitethernet2 3 P10 Gi2 4 Gigabitethernet2 4 P11 Gi2 1 Gigabitethernet2 1 P12 Gi2 2 Gigabitethernet2 2 P13 Gi2 7 Gigabitethernet2 7 P14 Gi2 8 Gigabitethernet2 8 P15 Gi2 5 Gigabitethernet2 5 P16 Gi2 6 Gigabitethernet2 6 P17 Gi2 11 Gigabitethernet2 11 P18 Gi2 12 Gigabitethernet2 12 P19 Gi2 9 Gigabitethernet2 9 P20 Gi2 10 Gigabitethernet2 10 P21 Gi2 15 Gigabitethernet2 15 P22 Gi2 16 Gigabitethernet...

Страница 15: ...BL 2883 01 to port J1 on the DuraNET 3300 and the other end of the cable to the unpowered DC power source 2 Connect network cable CBL 2884 01 to port J2 on the DuraNET 3300 a Connect either the RS 232 or USB communication link to PC1 USB or serial port 3 Connect network cable CBL 2885 01 to port J3 on the DuraNET 3300 4 Connect Optical cable CBL 2886 01 to port J4 on the DuraNET 3300 ...

Страница 16: ...d to ensure proper communication The installation instructions will be tailored for both Windows 10 and Linux operating systems for multi user preference and experience See appendix A for the install of required software Linux Open a terminal window If this is the first time opening a terminal window you will need to set the baud rate for the console port If this is not the first time you can simp...

Страница 17: ... 21 Page 17 of 84 Under setup option enter E and change the Bps Par Bits to 9600 8N1 Figure 2 4 Minicom Baud Then save as default and exit Figure 2 5 Minicom Default To confirm correct configuration and communication link Hit return and confirm the Cisco CLI prompt is displayed o Switch ...

Страница 18: ...tions www putty org Download PuTTY installation o PuTTY 64bit 0 74 installer Software installation can be accomplished by following the instructions from the URL page o https www ssh com ssh putty windows install Execute and Configure the PuTTY installer Open the Windows Explorer right click on the Windows logo in the bottom left corner navigate to the Downloads directory or wherever you saved the...

Страница 19: ...tall the software Almost always it is best to use the default value Just click Next Figure 2 7 PuTTY Destination Then the installer asks to select product features to install You probably want to add a shortcut on the desktop if you expect to use the software frequently All the other options generally should be enabled When ready click Install Figure 2 8 PuTTY Features ...

Страница 20: ...0 Quick Start Guide Page 20 of 84 MNL 0676 01 Rev A4 ECO N A Effective 26 Feb 21 When the installation has completed successfully it should show a Completed screen Click Finish to exit the installer Figure 2 9 PuTTY Completed ...

Страница 21: ...tware Otherwise you should be able to find the software from the Windows Start menu in the bottom left corner of the screen The menu looks different in each version of Windows On Windows 10 scroll down until you see PuTTY Open the group and select PuTTY When the software starts you should get a window with the title PuTTY Configuration Figure 2 10 PuTTY Configuration At this point you need to conf...

Страница 22: ... Feb 21 From the PuTTY configuration window select Serial and enter the COM port number then select Open You should now be connected to the DuraNET 3300 Console Figure 2 12 PuTTY Configuration with COM Press the Enter key to display the DuraNET 3300 console prompt Switch Figure 2 13 Console Prompt ...

Страница 23: ... static IP address Instruction for setting a static IP address can also be found here https stevessmarthomeguide com setting up static ip address windows 10 To set up a static address 1 Click on the Windows icon 2 Click the Settings icon 3 The windows setting screen appears click on the Network and Internet link ...

Страница 24: ...User Manual DuraNET 3300 Quick Start Guide Page 24 of 84 MNL 0676 01 Rev A4 ECO N A Effective 26 Feb 21 4 In the Network status pane locate the change adapter options link and click it ...

Страница 25: ... see your network adapters If your PC is equipped with two as most are then only use one and disable the other 6 Right click on the icon and select properties from the drop down list The Ethernet adapter is being used and the Wi Fi adapter is disabled If both adapters are enabled and connected undesired results may occur ...

Страница 26: ...er Manual DuraNET 3300 Quick Start Guide Page 26 of 84 MNL 0676 01 Rev A4 ECO N A Effective 26 Feb 21 7 Use the scroll bar to locate TCP IPv4 and click it to highlight and then click the properties button ...

Страница 27: ...0676 01 Rev A4 ECO N A Effective 26 Feb 21 Page 27 of 84 If you are using DHCP then you should see a screen like the one below You can uncheck the automatic assignment of IP address and or DNS server address Then enter your own details as show below ...

Страница 28: ...User Manual DuraNET 3300 Quick Start Guide Page 28 of 84 MNL 0676 01 Rev A4 ECO N A Effective 26 Feb 21 ...

Страница 29: ...Rev A4 ECO N A Effective 26 Feb 21 Page 29 of 84 Setting an Open Firewall Port To allow pings and data communication between the network port of this PC and the world we need to open a Firewall Port Open the Control Panel Navigate to the System and Security ...

Страница 30: ...User Manual DuraNET 3300 Quick Start Guide Page 30 of 84 MNL 0676 01 Rev A4 ECO N A Effective 26 Feb 21 Windows Defender Firewall Advanced Settings ...

Страница 31: ...l the open windows USB Console Port Physically connect the USB cable from the J2 cable set to a USB port on the PC Linux Open a terminal window From the terminal window prompt enter o sudo minicom o password for parvus parvus if asked for a password Power on the DUT o Boot information should begin to scroll in this terminal window o At the end of the boot listing information approximately 2 5min s...

Страница 32: ...a bits 1 stop bit no parity no flow control Assign the COM port number as identified above To confirm correct configuration and communication link o Hit return and confirm the CLI prompt o Switch RS 232 Console Port Physically connect the RS232 cable Null Modem from the J2 cable set to a RS232 port on the PC If the PC doesn t have an RS232 port you will need to use a USB to RS232 adapter including...

Страница 33: ...leared It is recommended to reenable these settings with the following commands enable config t license smart reservation license smart transport off service declassify erase nvram end copy run start license smart reservation Specific License Reservation allows customers in highly secure networks to utilize smart licenses without communicating the license information license smart transport off Th...

Страница 34: ...ation EAU Configuration Figure 3 1 EAU Front View Table 3 1 EAU Connector Identification Part Numbers Recept acle Used For Recept acle Label of Pins Wire Gauge AWG Panel Connector Part Number Mating Cable Connector Part Number Power J1 5 14 Phoenix Contact 1415337 Phoenix Contact 1027478 shell with 1029396 contacts for pins 1 4 and 1029398 contact for pin 5 Copper I O J2 85 22 28 Glenair 801 033 0...

Страница 35: ...10 2SA Copper I O J2 85 22 28 Glenair 801 033 07M17 85SA Glenair 801 008 16M17 85PA Copper I O J3 130 22 28 Glenair 801 033 07M21 130SA Glenair 801 008 16M21 130PA Optical I O J4 4 N A Glenair 180 118 ZR08 11 4S1 shell 181 043 126C termini Glenair 180 118 ZR06 11 4P1 shell 181 043 126C termini Connector Pinouts This section provides the pinouts necessary for creating cables to connect to this asse...

Страница 36: ... 4 28VDC RETURN 5 CHASSIS GROUND Note Phoenix Contact will not be releasing the 1027478 until sometime in Q3 2020 delayed from Q4 2019 For customers that must start building a power cable before the 1027478 is available there is an alternate solution if the requirement is for a cable that is no more than 10 meters in length Phoenix Contact makes cable assemblies with a molded connector on one end ...

Страница 37: ...er Power Cable 1414807 5 Meter Power Cable 1414824 10 Meter Power Cable Table 3 6 J1 Production Connector Information Recept acle Used For Recept acle Label of Pins Wire Gauge AWG Panel Connector Part Number Mating Cable Connector Part Number Power J1 2 12 Glenair 801 033 07M10 2PA GlenAir 801 008 16M10 2SA Figure 3 4 J1 Production Pin Arrangement Table 3 7 J1 Connector Pinout J1 Pins Signal 1 28V...

Страница 38: ...ept acle Label of Pins Wire Gauge AWG Panel Connector Part Number Mating Cable Connector Part Number I O J2 85 22 28 AWG Glenair 801 033 07ZNU17 85SA Glenair 801 008 16ZNU17 85PA Table 3 9 J2 Production Connector Information Recept acle Used For Recept acle Label of Pins Wire Gauge AWG Panel Connector Part Number Mating Cable Connector Part Number I O J2 85 22 28 AWG Glenair 801 033 07M17 85SA Gle...

Страница 39: ...BE_P8 MDI3_N GBE Port 8 16 GBE_P3 MDI3_N GBE Port 3 59 GBE_P8 MDI2_N GBE Port 8 17 GBE_P3 MDI2_N GBE Port 3 60 GBE_P8 MDI1_N GBE Port 8 18 GBE_P3 MDI1_N GBE Port 3 61 GBE_P8 MDI0_N GBE Port 8 19 GBE_P3 MDI0_N GBE Port 3 62 NC No Connect 20 GBE_P1 MDI3_P GBE Port 1 63 GBE_P2 MDI3_P GBE Port 2 21 GBE_P1 MDI2_P GBE Port 1 64 GBE_P2 MDI2_P GBE Port 2 22 GBE_P1 MDI1_P GBE Port 1 65 GBE_P2 MDI1_P GBE Po...

Страница 40: ... MDI2_N GBE Port 5 8 ZEROIZE_INPUT Zeroize Input Discrete 49 GBE_P5 MDI3_P GBE Port 5 9 RS232_GND RS232 Ground 39 GBE_P5 MDI3_N GBE Port 5 10 RS232_RXD RS232 Console Receive Input 47 GBE_P6 MDI0_P GBE Port 6 11 RS232_TXD RS232 Console Transmit Output 56 GBE_P6 MDI0_N GBE Port 6 23 GBE_P1 MDI0_P GBE Port 1 46 GBE_P6 MDI1_P GBE Port 6 15 GBE_P1 MDI0_N GBE Port 1 55 GBE_P6 MDI1_N GBE Port 6 22 GBE_P1...

Страница 41: ...8 18 GBE_P3 MDI1_N GBE Port 3 59 GBE_P8 MDI2_N GBE Port 8 26 GBE_P3 MDI2_P GBE Port 3 67 GBE_P8 MDI3_P GBE Port 8 17 GBE_P3 MDI2_N GBE Port 3 58 GBE_P8 MDI3_N GBE Port 8 25 GBE_P3 MDI3_P GBE Port 3 3 NC No Connect 16 GBE_P3 MDI3_N GBE Port 3 24 NC No Connect 85 GBE_P4 MDI0_P GBE Port 4 33 NC No Connect 79 GBE_P4 MDI0_N GBE Port 4 34 NC No Connect 84 GBE_P4 MDI1_P GBE Port 4 43 NC No Connect 78 GBE...

Страница 42: ...Part Number I O J3 130 22 28 AWG Glenair 801 033 07ZNU21 130SA Glenair 801 008 16ZNU21 130PA Table 3 13 J3 Production Connector Information Recept acle Used For Recept acle Label of Pins Wire Gauge AWG Panel Connector Part Number Mating Cable Connector Part Number I O J3 130 22 28 AWG Glenair 801 033 07M21 130SA Glenair 801 008 16M21 130PA Figure 3 6 J3 Pin Arrangement Table 3 14 J3 Connector Pino...

Страница 43: ...P11 MDI2_N GBE Port 11 83 P18 MDI3_P GBE Port 18 19 GBE_P11 MDI1_N GBE Port 11 84 P18 MDI0_P GBE Port 18 20 GBE_P10 MDI3_P GBE Port 10 85 P18 MDI1_P GBE Port 18 21 GBE_P10 MDI2_P GBE Port 10 86 P18 MDI2_P GBE Port 18 22 GBE_P10 MDI1_P GBE Port 10 87 P16 MDI3_P GBE Port 16 23 GBE_P10 MDI0_P GBE Port 10 88 P16 MDI2_P GBE Port 16 24 GBE_P24 MDI2_P GBE Port 24 89 P16 MDI1_P GBE Port 16 25 GBE_P22 MDI3...

Страница 44: ...BE_P13 MDI3_P GBE Port 13 115 ISO_P21 MDI2_N GBE Port 21 51 GBE_P13 MDI2_P GBE Port 13 116 ISO_P17 MDI3_N GBE Port 17 52 GBE_P13 MDI1_P GBE Port 13 117 ISO_P17 MDI0_N GBE Port 17 53 GBE_P14 MDI3_N GBE Port 14 118 ISO_P17 MDI1_N GBE Port 17 54 GBE_P14 MDI2_N GBE Port 14 119 ISO_P17 MDI2_N GBE Port 17 55 GBE_P14 MDI1_N GBE Port 14 120 ISO_P19 MDI1_P GBE Port 19 56 GBE_P14 MDI0_N GBE Port 14 121 ISO_...

Страница 45: ..._P GBE Port 18 11 GBE_P10 MDI3_N GBE Port 10 95 P18 MDI3_N GBE Port 18 26 GBE_P11 MDI0_P GBE Port 11 126 P19 MDI0_P GBE Port 19 16 GBE_P11 MDI0_N GBE Port 11 125 P19 MDI0_N GBE Port 19 29 GBE_P11 MDI1_P GBE Port 11 120 P19 MDI1_P GBE Port 19 19 GBE_P11 MDI1_N GBE Port 11 127 P19 MDI1_N GBE Port 19 28 GBE_P11 MDI2_P GBE Port 11 121 P19 MDI2_P GBE Port 19 18 GBE_P11 MDI2_N GBE Port 11 128 P19 MDI2_N...

Страница 46: ...BE_P14 MDI3_N GBE Port 14 36 P22 MDI3_N GBE Port 22 72 GBE_P15 MDI0_P GBE Port 15 80 P23 MDI0_P GBE Port 23 60 GBE_P15 MDI0_N GBE Port 15 91 P23 MDI0_N GBE Port 23 75 GBE_P15 MDI1_P GBE Port 15 81 P23 MDI1_P GBE Port 23 63 GBE_P15 MDI1_N GBE Port 15 92 P23 MDI1_N GBE Port 23 74 GBE_P15 MDI2_P GBE Port 15 82 P23 MDI2_P GBE Port 23 62 GBE_P15 MDI2_N GBE Port 15 93 P23 MDI2_N GBE Port 23 73 GBE_P15 M...

Страница 47: ...For Receptacle Label of Pins Fiber Rating Panel Connector Part Number Mating Cable Connector Part Number Optical I O J4 4 50 125um OM3 OM4 multimode Amphenol NG03 BD12 shell M29N0226Y termini Amphenol NG02 BD12 shell M29N0226Y termini Figure 3 7 J4 Pin Arrangement Table 3 17 J4 Connector Pinout J4 Pin Signal Function 1 CH1_RX Channel 1 Receive 2 CH2_RX Channel 2 Receive 3 CH2_TX Channel 2 Transmit...

Страница 48: ...ss Username and Password need to be assigned Ensure a PC is connected to the DuraNET 3300 via the USB or RS232 Console and powered on Linux Windows 10 Open a terminal window to communicate via the USB or RS232 Console from the PC to the DuraNET 3300 For Linux that would be minicom and for Windows it would be PuTTY Execute the following CLI commands to set the IP Address o switch enable o switch co...

Страница 49: ...168 1 150 ensure the computer that is connected to VLAN1 is configured with the same subnet e g 192 168 1 100 This can be done by setting a static IP address On the left panel select Administration Software Management Choose the following settings Upgrade Mode BUNDLE Transport Type Desktop HTTPS Source File Path select new image Destination Flash Click the Download button and wait for completion O...

Страница 50: ...ands o switch enable o switch sho configuration The configuration option may show Version 17 1 This is representative only as your system may have a different Cisco IOS Figure 4 1 Show Configuration Listing To confirm and verify the IOS file name and version o switch enable o switch sho boot The boot option will list the complete file name including embedded version Figure 4 2 Show Boot Listing ...

Страница 51: ...stall and Configure the Server PC1 only Excerpts taken from Access Router Software Upgrade Procedure TFTP Trivial File Transfer Protocol is a simplified version of FTP File Transfer Protocol Installing TFTP Server Note Ensure you have an Internet connection From PC1 open a terminal window Figure 4 3 and execute the following commands sudo apt update The APT package repository cache should be updat...

Страница 52: ...should be installed Figure 4 5 5 Figure 4 5 tftpd hpa package installed Now check whether the tftpd hpa service is running Figure 4 6 sudo systemctl status tftpd hpa Figure 4 6 Check whether the tftpd hpa service is running If you see something similar to Figure 4 7 then the tftpd hpa service is running and next we configure it ...

Страница 53: ...the default configuration of the TFTP server See figure 4 9 below Here TFTP_USERNAME is set to tftp It means the TFTP server will run as the user tftp TFTP_DIRECTORY is set to var lib tftpboot It means var lib tftpboot is the directory on this server which you will be able to accessing via TFTP TFTP_ADDRESS is set to 69 It means TFTP will run on port 69 TFTP_OPTIONS is set to secure This variable ...

Страница 54: ...the TFTP_DIRECTORY to tftp and add the create option to the TFTP_OPTIONS Without the create option you won t be able to create or upload new files to the TFTP server You will only be able to update existing files Figure 4 10 Figure 4 10 Adding the create option The final configuration file should look as above Now press Ctrl x followed by y and then Enter to save the changes ...

Страница 55: ...See Figure 4 12 sudo chown tftp tftp tftp Figure 4 12 Change the owner and group Now restart the tftpd hpa service as shown in Figure 4 13 sudo systemctl restart tftpd hpa Figure 4 13 Restart the tftpd hpa service Now check whether the tftpd hpa service is running Enter as shown in Figure 4 14 sudo systemctl status tftpd hpa Figure 4 14 Enter command to check that tftpd hpa service is running As y...

Страница 56: ... to the Router From PC1 execute Ping 192 168 1 100 router address to confirm Now that you have IP connectivity and can ping between the computer that acts as a TFTP server and router you can copy the Cisco IOS Software image to the flash Copy IOS Image to the Router Note Before you copy the image ensure that you have started the TFTP server software on your PC and that you have the file name menti...

Страница 57: ... is in progress When complete confirm with the following CLI commands switch cd flash switch dir You should see the new file in the flash directory switch config t switch config boot system flash ess3x00 universalk9 17 01 01 SPA bin Case sensitive switch config exit switch write memory switch show boot switch reload confirm To view the tftp directory cd tftp dir ...

Страница 58: ...rts and watts supported for PoE PoE can provide 30 0 watts at the device at a voltage between 42 5 and 57 volts Two operating modes are defined in PoE Positive power is supplied to Ethernet pair 1 2 for Mode A and to pair 4 5 for Mode B Negative power is supplied to 3 6 for Mode A and to pair 7 8 for Mode B For longer cable 100 m CAT6 is recommended due to higher current carrying capacity Figure 4...

Страница 59: ...age 59 of 84 Figure 4 17 minicom IP address The Username and Password can be found from the minicom window switch enable switch sho running config bri From PC1 open a web browser such as Firefox Enter the DUT IP address in the URL window to bring up a Cisco GUI login Username DuraNET Password 3300 ...

Страница 60: ...ive 26 Feb 21 Figure 4 18 DUT Login Window From the GUI navigate to Administration Power Management Total Power Supported Block Watts enter total power requirement in the Block of 125 Watts as shown below within the red oval in figure 4 18 then click outside the block Figure 4 19 DUT Login Window ...

Страница 61: ...v A4 ECO N A Effective 26 Feb 21 Page 61 of 84 Select Yes as shown in figure 4 20 Figure 4 20 Click Yes to continue Navigate back to dashboard to confirm setting of 125 watts as shown in POE Power Consumption pie chart red oval Figure 4 21 PoE power consumption box ...

Страница 62: ...der service declassify The zeroization process starts as soon as the physical trigger Zeroize Discrete is asserted for at least one second The CLI command service declassify is used to set the desired action in response to the Zeroize Discrete assertion To prevent accidental erasure of the system configuration image the default setting is set to no service declassify Command Line Interface There a...

Страница 63: ...lash file system switch ROMMON prompt Zeroization Trigger The user needs to assert the physical Zeroize Discrete button after configuring the level of erasure required by the above CLI commands To make sure that the assertion has been identified by the underlying software the physical Zeroize Discrete button must be asserted for at least ONE second Recovery Procedures Complete these steps in order...

Страница 64: ...O N A Effective 26 Feb 21 switch ping 192 0 2 1 Type escape sequence to abort Sending 5 100 byte ICMP Echoes to 192 0 2 1 timeout is 2 seconds Success rate is 100 percent 5 5 round trip min avg max 1 2 4 ms 3 Copy the image via tftp switch copy tftp location directory bundle_name flash ...

Страница 65: ...ding connectors and mounting feet 6 75 x 6 25 x 3 50 17 15cm x 15 88cm x 8 89 cm Chassis aluminum alloy corrosion resistant Cooling passive natural convection fan less Ingress protection dust and water resistant similar to IP67 Finish black anodize finish per MIL A 8625 Type II Class 2 Rugged Connectors o Glenair Mighty Mouse 801 series 1GBaseT ports console and zeroize also power input for produc...

Страница 66: ...re as low as possible Every effort has been made to meet stringent thermal performance criteria as outlined in the specifications However it is always good practice to keep the DuraNET 3300 as cool as possible avoiding environments which do not allow the thermal conduction and or natural convection of heat away from the unit Vertical Mounting To install the DuraNET 3300 vertically on a mounting su...

Страница 67: ...g surface that matches the pattern shown in Figure 5 3 The mounting holes are 0 33 in diameter 4 Attach the switch to the mounting surface using the two side mounting holes Attachment screws should be 5 16 18 Important Ensure that mounting screw length allows proper thread engagement of the mounting hardware but is not so long that the screw bottoms out in the side mounting hole Figure 5 3 Side Mo...

Страница 68: ...hole for attachment of a grounding cable using a 1 4 20 screw is provided on the rear of each module of the system It is recommended that you use only one grounding hole Choose the grounding hole that allows the shortest grounding cable length Caution The grounding lug tie holes are shallow 0 350 Select the proper screw length for your grounding application and avoid over tightening Figure 5 4 Rea...

Страница 69: ...30W of output maximum at 65 C configurable by the IOS software to manage the number of ports and watts of output Environmental Specifications Temperature Operating temperature 40 to 71 C 40 to 160 F ambient per MIL STD 810G Methods 501 5 and 502 5 and 40 to 70 C per DO 160G Sect 4 Cat A2 and D2 and Section 4 5 5 Category V Table 4 1 Storage temperature 55 to 85 C per DO 160G Sect 4 Cat A2 and 40 t...

Страница 70: ...re 40 to 71 C 40 to 160 F ambient o Caveat with full 125W of PoE injection operating range up to approx 65 C Humidity operating transport up to 95 RH 40 C non condensing Ingress dust sand no ingress similar to IP6x Fungus resistant Water immersion no leakage per 1 meter submersion similar to IPx7 Operating Altitude Up to 50 000ft 15 240m Storage Altitude Up to 60 000ft 18 300m Cisco Specifications...

Страница 71: ...cast multicast broadcast SCP SSH SNMPv3 TACACS RADIUS server client MAC address notification BPDU guard RMON MACsec 128 o Layer 2 Line rate Encryption and Information Assurance IA o IEEE 802 1AE MACsec support on 1GBaseT ports for point to point authentication and encryption of Ethernet LAN traffic o MACsec supports key exchange from switch to switch or switch to end points using SAP MKA protocols...

Страница 72: ... RFC Compliance o RFC 768 UDP RFC 793 TCP RFC 826 ARP o RFC 783 TFTP RFC 1305 NTP o RFC 791 IPv4 protocol RFC 1166 IP Addresses o RFC 854 Telnet RFC 959 FTP o RFC 1157 SNMPv1 RFC 1901 1902 1907 SNMPv2 o RFC 2273 2275 SNMPv3 RFC 2571 SNMP Management o RFC 792 ICMP RFC 1256 ICMP Router Discovery o RFC 1492 TACACS RFC 1757 RMON o RFC 1493 Bridge MIB Objects o RFC 1643 Ethernet Interface MIB o RFC 206...

Страница 73: ...MIB o CISCO PRIVATE VLAN MIB o CISCO PROCESSMIB o CISCO PRODUCTS MIB o CISCO ENTITYALARM MIB o CISCO SNMP TARGET EXT MIB o CISCO STP EXTENSIONS MIB o CISCO SYSLOGMIB o CISCO UDLDP MIB o CISCO VLAN IFTABLERELATIONSHIP MIB o CISCO VLAN MEMBERSHIPMIB o CISCO VTP MIB o ENTITY MIB o ETHERLIKE MIB o HC RMON MIB o IEEE8021 PAE MIB o IEEE8023 LAG MIB o IF MIB o LLDP EXT MED MIB o LLDP MIB o NOTIFICATION L...

Страница 74: ... humidity tin whisker mitigation Mean Time Between Failure MTBF calculated per MIL HDBK 217F see qualification report Export Jurisdiction ITAR free EAR controlled ECCN 5A001 A1 Regulatory Compliance European CE Mark including RTCA DO 160G MIL STD 461F G MIL STD 704F MIL STD 1275D E RoHS 3 REACH compliant Warranty 1 year return to depot warranty Warranty extensions and multi year service agreements...

Страница 75: ...t curtisswright com Phone 1 801 433 6322 Fax 1 801 483 1523 Returning for Service Before returning any Parvus product please fill out a Return Material Authorization RMA request form available for download from the following website under the support section www curtisswrightds com Email this form to the Technical Support email address slp_tsupport curtisswright com to receive authorization for sh...

Страница 76: ... Curtiss Wright Defense Solutions Division 3222 S Washington St Salt Lake City Utah USA 84115 T 1 801 483 1533 F 1 801 483 1523 www curtisswrightds com Sales T 1 800 483 3152 or 1 801 483 1533 slp_sales curtisswright com Product Technical Support T 1 801 433 6322 slp_tsupport curtisswright com Customer Feedback slp_feedback curtisswright com ...

Страница 77: ...rom a Firefox browser you may encounter the following access failure To correct this From the Firefox home page click on the symbol located in the upper right corner This will bring up a list of options Navigate to Help then navigate to Troubleshooting Information This will presented the following web page Under the heading Give Firefox a tune up select Refresh Firefox This should resolve the fail...

Страница 78: ...do minicom s The s allows for minicom setup of which the following should be confirmed Serial Device dev ttyUSB0 Bps Par Bits 9600 8N1 Hardware Flow Control No Software Flow Control No To confirm the Serial Device dmesg grep tty To list the active USB port ls grep USB Once minicom has been setup the s option is longer needed simply execute sudo minicom For additional information https developer ri...

Страница 79: ... t60 Note i is the time in seconds the terminal will be updated with results t is the length of the test in seconds The IP address 192 168 1 may be different for your machine To run iperf from a selected IP source o iperf I source IP address destination IP address To determine maximum bandwidth using a single CAT 5 cable between PC1 and PC2 o run iperf s on PC1 o run iperf c 192 168 1 140 i5 t60 o...

Страница 80: ...o Linux PCs Linux1 IP address 192 168 1 140 Desktop DuraNET 3300 Software PacketLossServer c Linux2 IP address 192 168 1 100 Desktop DuraNET 3300 Software PacketLossClient c From their respective directory on the two PCs compile the c files gcc PacketLossServer c o PacketLossServer gcc PacketLossClient c o PacketLossClient From their respective directory paths execute the files starting with the S...

Страница 81: ...User Manual DuraNET 3300 Appendix A MNL 0676 01 Rev A4 ECO N A Effective 26 Feb 21 Page 81 of 84 ...

Страница 82: ...ESS 3300 Port Name LC1 Connected Te1 1 LC2 Connected Te1 2 P1 Connected Gi1 5 P2 Connected Gi1 6 P3 Connected Gi1 3 P4 Connected Gi1 4 P5 Connected Gi1 9 P6 Connected Gi1 10 P7 Connected Gi1 7 P8 Connected Gi1 8 P9 Connected Gi2 3 P10 Connected Gi2 4 P11 Connected Gi2 1 P12 Connected Gi2 2 P13 Connected Gi2 7 P14 Connected Gi2 8 P15 Connected Gi2 5 P16 Connected Gi2 6 P17 Connected Gi2 11 P18 Conn...

Страница 83: ...ective 26 Feb 21 Page 83 of 84 Glossary Term Definition Description IOS XE Cisco s operating system for their enterprise network devices switches routers etc 10GBASE SR A 10 Gigabit optical Ethernet standard Various fiber classes allow 300 400 meter max cable length ...

Страница 84: ...ctive 26 Feb 21 Parvus back cover 8 5 x 11 picture inserted in front of text DO NOT DELETE THE COMMENTS OR THIS PAGE These comments are only visible in Normal view The picture hides the header and these comments when you print the manual or view it in Print Layout or Print Preview ...

Отзывы: