DESCRIPTION
PART №
ITEM
WC-5602
WC-6118-01
WC-4303
WC-5335
WC-5502-01
WC-5510
WC-2401
WC-3528
WC-5334
WC- 501
WC- 608-101
WC-2100
WC-2005
WC-2024
WC-2006
WC-3705
WC-1800HW
WC-3217
WC- 801
WC- 858
WC-3700
WC- 922-04
WC- 511
LID, 6 GAL WITH KNOB
COLLAR, TOP
O-RING, LINERS RU
TUBING, 8” WATER INLET
PROBE, WATER LEVEL
COVER, PROBE WA WB14
ELBOW, 3/8 NPT X 1/4 FLARE PLATED
LEG, 4” ADJUSTABLE 3/8-16 THREAD ITALIAN STYLE
TUBING, 15-1/2” WATER INLET
KIT, THERMOSTAT WB-14
CONTROL BOARD, LIQUID LEVEL 120/240VAC
GAUGE GLASS ASSY, 7”
WASHER, 1/8” SHIELD CAP
GLASS, GAUGE 7”
WASHER, 3/16” SHIELD BASE
REPAIR KIT, S FAUCET
FAUCET, S’ SERIES H/W
KNOB, ELECTRIC THERMOSTAT
VALVE, INLET BRASS ½.50 GPM 120V 10W FOR WB-14-12
VALVE, INLET BRASS .50 GPM 220V 10W FOR WB-14-60
REPAIR KIT, INLET VALVE
KIT, HEATING ELEMENT 3.5KW 220V W/JAM NUTS & SLCN WSHRS
THERMOMETER, DIAL RU’S
Parts List
Setup Steps Continued
3. Connect the water line to the water inlet fitting on the rear of the unit. Water volume going to the machine should be consistent.
Use tubing sized sufficiently to provide a minimum flow rate of two gallons per minute.
4. Connect the unit to electrical outlet with appropriate amperage rating (refer to schematic for power requirements).
5. Turn on the circuit running power to unit. The water inlet valve will open, filling the unit. When the boiler has filled, turn on
boiler at the thermostat, twisting the knob clockwise.
6. Heating tank will require 50 to 60 minutes to attain operating temperature. Thermostat indicator will light at this time.