![Curtis WB-14-12 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/curtis/wb-14-12/wb-14-12_service-manual_2699152001.webp)
MODELS INCLUDED
•
WB-14-12
•
WB-14-60
CAUTION: Please use
this setup procedure
before attempting to use
this appliance. Failure to follow the
instructions can result in injury or the
voiding of the warranty.
WARNING
HOT LIQUID,
Scalding may occur.
Avoid splashing.
WARNING: DO NOT
place this water boiler
closer than six [6] inches
from wall. Unit must have
adequate cross-ventilation.
CAUTION: DO NOT
connect this unit to hot
water. The inlet valve is
not rated for hot water.
FOR THE LATEST SPECIFICATIONS AND INFORMATION GO TO WWW.WILBURCURTIS.COM
Service Manual – WB-14 Water Boiler
W
ilbur
C
urtis
C
ompany
, i
nC
.
Important Safeguards/Symbols
Symbols:
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
This equipment is designed for commercial use. Any servicing
other than cleaning and routine maintenance should be per-
formed by an authorized Wilbur Curtis Company service techni-
cian.
• DO NOT immerse the unit in water or any other liquid
• To reduce the risk of fire or electric shock, DO NOT open
service panels. No user serviceable parts inside.
• Keep hands and other items away from hot areas of the unit
during operation.
• Never clean with scouring powders or harsh chemicals.
INSTALLATION
This Curtis unit is pre-set and ready to go from the factory.
System Requirements:
• Water Supply : 20 – 90 PSI (Min Flow Rate 2 gpm) • Electrical: Refer to Electrical Schematic.
Factory Settings:
• Water Temperature: 200
ºF
• Water Volume: 14 Gallons
NOTE: A water filtration system must be used to help maintain trouble-free operation. In areas
with extremely hard water, we highly recommend the use of a Curtis approved water filter. (For
our full line of filters, please log on to www.wilburcurtis.com) A water filtration system will greatly
prolong the life of the unit and enhance the quality and taste of the product.
SETUP STEPS
1. The unit should be level (left to right - front to back), on a secure surface.
2. Install the supplied water faucet on the faucet shank in front of the unit.
NSF requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required
so that the unit can be moved for cleaning.
2. This unit must be installed with adequate backflow protection to comply with applicable
federal, state and local codes.
3. Water pipe connections and fixtures directly connected to a portable water supply shall be
sized, installed and maintained in accordance with federal, state, and local codes.
C
ISO 9001:2008 REGISTERED
WILBUR CURTIS CO.
6913 Acco Street,
Montebello, CA 90640-5403
For the latest information go to
www.wilburcurtis.com
Tel: 800/421-6150
Fax: 323/837-2410