Electric Thermostat
Adjustment
ELECTRIC THERMOSTAT ADJUSTMENT
On electric water boilers, thermostats are set at the factory to cut off at 200ºF. We do not recom
-
mend changing this. If necessary, adjustment is as follows:
1. Rotate the thermostat knob to the right to the BOIL position. Pull off the knob.
2. Locate the tiny adjustment screw, inside the stem (see figure 1). Using a small screwdriver,
adjust the temperature up or down:
a. By turning the screw ¼ turn to the left will increase the temperature about 20°F.
b. Turning ¼ to the right will decrease the temperature by 20°F.
c. To set the thermostat precisely at 200°F, insert a thermometer probe into the water jacket
through the steam hole (just under the sprayhead). Turn the screw ½ turn to the left.
d. When the thermometer reaches 200°F, slowly turn the adjustment screw to the right until
the pilot light turns off.
3
DESCRIPTION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
WC-5602
WC-1800HW
WC-3705HW
WC-1902
WC-1903
WC-1906
WC- 511
WC-5502
WC-3914
WC-2966
WC-5386
WC- 922-04
WC-37136
WC-3220
WC-3217
WC- 608
WC-5611
WC-2401
WC- 801
WC-3700
WC- 813
PART
Nº
INDEX
Nº
LID WITH KNOB
FAUCET, “S” SERIES HOT WATER 1-1/32-14 UNS
KIT, FAUCET S SERIES HOT WATER
SHANK, FAUCET PLAIN W/NUTS
NUT, UNI0N SHANK WB-10
“C” RING .917 X .760 X .090
THERMOMETER, DIAL RU’S
PROBE, WATER LEVEL
LABEL, “HOT WATER” (WB-10)
FITTING, WATER INLET WB-10
TUBING ASSEMBLY, WATER INLET
ELEMENT, HEATING 3.5KW 220V W/NUTS & WSHRS
KIT, THERMOSTAT WB-10-12
BEZEL, THERMOSTAT ELECTRIC
KNOB, ELECTRIC THERMOSTAT
LEVEL CONTROL, WATER 120V
COVER, BOTTOM WB-10
ELBOW, 3/8 NPT X 1/4 FLRE PLTD
VALVE, INLET BRASS .50 GPM 120V 10W RU/WB
KIT, INLET VALVE REPAIR
FLOW WASHER, .5GPM .5” S45