background image

7

SERVICING

Completely drain the unit of any coffee. Allow server to cool. Unscrew and remove the lid and tube assembly. 

  REPLACING THE GAUGE GLASS

  The gauge glass can be removed for maintenance and cleaning. 

  1.  Remove the gauge glass shield by pulling upward.

  2.   Carefully, pull up on the gauge glass to free it from the silicone base gasket that sits on the faucet assembly.

  3.  Pull off the silicone cap on top of the tube. 

  4.  Scrub inside the glass with a tube cleaning brush and mild detergent solution. Inspect the glass tube 

   

for cracks or chips. 

WARNING – If gauge glass was broken, carefully remove all traces of glass. Brush out the silicone 

base. From inside the liner, brush out the faucet shank. Run clear water through the shank to make 

sure any glass shards have been washed from the faucet and base.

  5.  Check the top cap and bottom silicone base. Clean these fittings, making sure they are not leaking. 

   

Replace if necessary. 

  6.  Once clean and dry, replace all parts that were serviced.

  SERVICING THE FAUCET

  The faucet will require periodic cleaning and maintenance.

  2.   Disassemble the faucet. Unscrew the bonnet from the body of the faucet.

  3.   Remove the faucet handle by pressing inward on the seat cup (see illustration, right) then unhooking 

   

the handle from the center shaft.

  4.   The seat cup, center shaft and spring will now separate from the bonnet.

  5.   You may now clean the parts of the faucet (illustration, bottom right). Check the seat cup for tearing or

   

 splitting. Make sure that the faucet spring is free of corrosion. Replace these items if necessary.

BREWING INTO SERVERS

Use only coffee or water in the insulated dispenser. Do not use the thermoserver to dispense any other 

beverage. Preheating is recommended.
  1.  Place a clean and empty server centered under the brewcone of the Milano brewer.
  2.  Make sure the screen reads READY TO BREW.
  3.  Fill brewcone with the correct measure of ground coffee for the volume of coffee you wish to brew.
  4.  Press the desired brew button on the side of the brewer with server you wish to brew into.
  5.  Allow coffee in the brewcone to drip completely before removing the insulated server.

WARNING

 – SERVERS MAY BE HEAVY WHEN FILLED. 

CARE MUST BE TAKEN WHEN TRANSPORTING TO AVOID DROPPING OR SPILLING.

TLCG1509S Milano 1.5 Gallon Server Instructions

Cleaning and Sanitizing Instructions for TLCG15

These cleaning and sanitizing instructions are only a guide line to be used for the cleaning and sanitizing of 

the TLCG15. Your current in-house cleaning and sanitizing methods may be just as effective.

For cleaning and sanitizing of the TLCG15, the three sink method is recommended. This method consists of 

a sink of water filled with a detergent and water solution, a fresh water rinse, and a sink filled with an aqueous sanitizing solution. 

Immersion of parts in commercial BarTabs/Sani-Tabs sanitizing solution is recommended. The solution must be warm (75°F.) Let the 

parts soak at least one minute.

HANDLE 

 

 

 

BONNET 

 

 

SPRING 

 

SHAFT 

 

SEAT CUP 

 

CAUTION  

  Do not immerse in water. 

  Do not place in dishwasher. 

  Do not use harsh powders or cleansers containing chlorine.

  Do not use a wire brush or pot scour to clean inside liner.

 

1. Daily, Rinse the unit after use.

 

a.  Rinse unit with hot water.

 

b.  Fill unit with hot water.

 

c.  Open unit and empty contents completely.

2. Clean and sanitize the lid assembly.

 

a.  Remove lid from unit and submerse it in cleaning solution, cleaning thoroughly.

 

b.  Using a tube cleaning brush, clean inside the filling tube.

 

c.  Rinse with clean water.

 

d.  Submerse in sanitizing solution for 5 minutes then air dry completely.

Содержание TPC2S

Страница 1: ...d Class 2 Wiring Only on brewer and grinder Connect the two with the cable plug 3 Connect the unit to an appropriate electrical power circuit 4 Turn on the toggle STANDBY ON switch behind the unit The...

Страница 2: ...om right brew button The screen will display wait until is displayed Enter the 4 digit access code the code cor responds to the buttons illustrated below The default code set at the factory is 1 2 3 4...

Страница 3: ...3 Programming Control Module Menu Tree The flow chart displays the sequence of menu items that can be accessed through the UCM...

Страница 4: ...4 PARTS DIAGRAM 1 2 3 4 5 6 7 8 A B C 9 10 11 12 13 14 15 16 17 18 19 20 23 26 27 28 29 30 31 32 33 34 35 36 37 38 24 25 21 22...

Страница 5: ...CTION RIGHT COVER TOP KIT DUMP VALVE RIGHT 120V 14W VALVE BREW DUMP RIGHT 240V 12W TP TPC FITTING SPRAYHEAD VALVE BY PASS W RESISTOR VALVE BY PASS 220V NON ADJUSTABLE RSTR SOLENOID LOCK BREWCONE RIGHT...

Страница 6: ...6 ELECTRICAL SCHEMATIC...

Страница 7: ...everage Preheating is recommended 1 Place a clean and empty server centered under the brewcone of the Milano brewer 2 Make sure the screen reads READY TO BREW 3 Fill brewcone with the correct measure...

Страница 8: ...operate while timer is in the timing mode MINUTE The MINUTE button sets minutes Each time you press the MINUTE button an outline bar will be added Each bar represents 15 minutes starting from bottom t...

Страница 9: ...ess timer for 1 hours Press START STOP once Press HOUR button once Press MINUTE button twice 1 2 3 4 5 To interrupt timer press START STOP button again Screen will return to 1 hrs Press START STOP but...

Страница 10: ...hanical and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limite...

Отзывы: