Curtis GEMINI 200R Скачать руководство пользователя страница 13

2 2 0 V

WATTS

AMPS

 22O

 Single

3 6 7 5

 17

6 0

DATE

WIRING DIAGRAM

WIRES

PHASE

HZ

3 / 2 4 / 9 7

REV.

VOLTS

MODEL

3+ GND

BLUE #10

RED #10

WHITE #14

GREEN

5

4

3

2

1

12

12

12

12

12

12

12

12

12

12

12

12

6

7

8

9

10

DUAL

TIMER

WC-616

3 A

3 A

3 A

3 A

4B

3 A

WATER

INLET

VALVE

WC-826

THERMOSTAT

WC-517

123

123

123

LOW WATER
CUT - OFF
THERMOSTAT
WC-508R

BLACK

1 1

GEMINI 200R -10

WHITE

BROWN

WC-817

T4

T3

T2

T1

LIQUID  LEVEL

CONTROL

WC-608

PROBE

WC-5502

BLK

DUMP

VALVE

WARMER
WC-947

HOT

WATER

VALVE

WHITE

BLUE

BLACK

WC-818

BLUE

WHITE

WH

ORANGE

WHITE

PURPLE

BLACK

BLACK

24 CUP
WC-113R

12 CUP
WC-113R

BLACK

RED

WHITE

WC-200

BLACK

WC-200

BLACK

WHITE

POWER
SWITCH
WC-103

110V

L2

L1

N

G

BLACK

BLACK

WHITE

BLACK

GREY

BLACK

HOT
WATER
WC-112R

WARMER

WC-114R

ON/OFF
WC-111R

HTG. ELMT
WC-922

4

2

1

3

5B

4B

5B

4B

5B

4B

5B

4B

5B

Содержание GEMINI 200R

Страница 1: ...56789012 1234567890123456789012345678901212345678901234567890123456789012123 1234567890123456789012345678901212345678901234567890123456789012123 1234567890123456789012345678901212345678901234567890123...

Страница 2: ...on Elbow Legs Adjustable 4 Counter Gem 3 Satellite Server Faucet Guard Faucet 1 1 1 25 1 4 1 1 1 Qty Item Avoid electrical shock the body of this brewer must be securely grounded A GREEN grounding scr...

Страница 3: ...led on the incoming water line to the brewer IMPORTANT Brewer must be connected to COLD water line Water inlet valves are not rated for hot water 5 Remove the top cover 1 by loosening four screws 6 Ma...

Страница 4: ...2345678901234567890121234567890123 123456789012345678901234567890121234567890123 123456789012345678901234567890121234567890123 123456789012345678901234567890121234567890123 1234567 1234567 1234567 123...

Страница 5: ...eaking 3 Remove hot water spout aerator 13 and clean it at least once a week 4 The inside of the heating tank should be de limed at least every six months or more often in areas with especially hard w...

Страница 6: ...water condition persists check the opera tion of the liquid level control board Measure voltage at the input terminals T2 T3 of the L L C Your voltmeter should read approximately 115 volts It should a...

Страница 7: ...d it s mounting bracket All wire connections to the board should be tight Measure voltage at the input terminals T2 T3 of the L L C board Your voltmeter should read approximately 115 volts It should a...

Страница 8: ...e the timer If the timer is working check the coil on the dump valve If there is voltage you should read approximately 115 volts be tween the terminals If there is voltage the coil may be burned Repla...

Страница 9: ...Gemini System 200R Illustrated Parts List 7 9...

Страница 10: ...Gemini System 200R Illustrated Parts List 8...

Страница 11: ...W 120V NUT 8 32 KEP ZINC SPOUT HOT WATER NO SPLASH AERATOR CHROME PLATED FEMALE ADAPTOR AERATOR CHROME PLATED MALE WASHER 1 2 I D INTERNAL BRACKET FAUCET SUPPORT LABEL SWITCH PANEL W O HOT WATER LEG 4...

Страница 12: ...IGHT SCREW 6 32 x 7 8 PANHEAD SCREW 8 32x PHILLIPS TRUSS HD SS GUARD SHOCK BOARD LIQUID LEVEL CONTROL WASHER 8 EXTERNAL LOCK THERMOSTAT CAPILARY SPST 277V 22A O RING FITTING SPRAYHEAD FITTING BRASS PR...

Страница 13: ...ATER CUT OFF THERMOSTAT WC 508R BLACK 1 1 GEMINI 200R 10 WHITE BROWN WC 817 T4 T3 T2 T1 LIQUID LEVEL CONTROL WC 608 PROBE WC 5502 BLK DUMP VALVE WARMER WC 947 HOT WATER VALVE WHITE BLUE BLACK WC 818 B...

Страница 14: ...ONLY NO FAUCET OR LID LID SATELLITE PLASTIC GEM 3 GAUGEGLASSASSEMBLY 8INCH SHIELD CAP WITH VENT 77 4 SHIELD CAP WASHER 1 8 SHIELD FOR 8 INCH GAUGE GLASS GAUGE GLASS 8 INCH WASHER FOR SHIELD BASE 3 16...

Страница 15: ...1 3...

Страница 16: ...djustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of the equipment owner The owner is responsible for prop...

Отзывы: