background image

1

This appliance is designed for commercial use. Any servicing other than cleaning and maintenance should be performed by an autho-

rized Wilbur Curtis service center.

 

• Do NOT immerse the unit in water or any other liquid

 

• To reduce the risk of fire or electric shock, do NOT open top panel. No user serviceable parts inside. Repair should be done  

 

   only by authorized service personnel.

 

• Keep hands and other items away from hot parts of unit during operation.

 

• Never clean with scouring powders, bleach or harsh implements.

Conventions

WARNINGS – To help avoid personal injury

Important Notes/Cautions – from the factory

Sanitation Requirements

Your Curtis G3 System is Factory Pre-Set and Ready to Go… Right from the Carton.

Following are the Factory Settings for your interLock Coffee Brewing Systems:

 

• Brew Temperature = 200°F 

 

 

• Water Bypass = On LARGE & MEDIUM brew only

 

• Brew Volume = Large set to vessel requirements. 

• Energy Save Mode = Off

System Requirements:
 

• Water Source   20 – 90 PSI (Minimum Flow Rate of 1 GPM)

 

• Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model. 

SETUP STEPS

The unit should be level (left to right and front to back), located on a solid counter top.  Connect a water line from the water filter to the 

brewer. NOTE: Some type of water filtration device must be used to maintain a trouble-free operation. (In areas with extremely hard 

water, we suggest that a sedimentary and taste & odor filter be installed.) This will prolong the life of your brewing system and enhance 

coffee quality.  

1.  A 3/8”Flare x 3/8” Male pipe elbow is supplied with the brewer for water line connection. Use tubing sized sufficiently to provide a  

 

  minimum of 1.0 GPM.

2.  Connect the unit to an appropriate electrical power circuit.

3.  Turn on the toggle (STANDBY/ON) switch behind the unit. The heating tank will start to fill.  When the water level in the tank rises to the  

  correct volume, the heating elements will energize automatically.  With G3 Systems there is no danger of element burnout caused by   

  an empty tank.

4.  The heating tank will require 20 to 30 minutes to reach operating temperature (200°F), indicated when READY TO BREW is displayed  

  on the LCD screen.

5.  Prior to brewing, dispense 12 ounces of hot water through the hot water faucet.

6.   Brew a cycle of at least 12 ounces, to purge the water lines of any air that may be trapped after filling.

NSF International requires the following water connection:

1.  A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine can be moved  

 

for cleaning underneath.

2.  In some areas an approved backflow prevention device may be required between the brewer and the water supply.

W

ilbur

 C

urtis

 C

ompany

, i

nC

.

Models

 

  GEM TN

 

  GEM-3N

 

  GEM-5N

CAUTION: DO NOT 

connect this brewer to hot 

water. The inlet valve is 

not rated for hot water.

CAUTION: Please use 

this setup procedure 

before attempting to use 

this brewer. Failure to follow the 

instructions can result in injury or the 
voiding of the warranty.

WARNING

 HOT LIQUID, 

Scalding may occur. 

Avoid splashing. 

IMPORTANT: Equipment 

to be installed to comply 

with applicable federal, 

state, or local plumbing/electrical 

codes having jurisdiction.

Important Safeguards/Conventions

Service Manual – Gemini Narrow Twin Brewer

BREWING INSTRUCTIONS

  1.  Brewer should be ON (Confirm at rear toggle switch, then press the ON/OFF button). Ready-to-Brew should be on the display. If the  

    brewer is connected to an InterLock grinder, the grinder should be on. When Interlock connection is made, grind coffee at this time.

  2.  Place an empty Satellite under the brewcone and press the warmer switch to pre-heat the Satellite.

6.  Press Brew button.    

  Brewing will begin    

  immediately.

5.   Transfer filled  

  brewcone to  

  brewer.

  3.  Place a clean filter  

    into the brewcone.

4. Fill brewcone with    

  ground coffee.

Содержание GEM TN

Страница 1: ...The heating tank will start to fill When the water level in the tank rises to the correct volume the heating elements will energize automatically With G3 Systems there is no danger of element burnout...

Страница 2: ...Water will fill the tank approximately 2 3 minutes depending on water flow rate When the proper level is reached will appear on the screen It takes approximately 20 minutes to reach setpoint temperat...

Страница 3: ...EM SOLENOID LOCK BREWCONE L R LABEL UCM OUTER DUAL TWIN KIT UCM CONTROL MODULE LABEL UCM OVERLAY 1 BATCH LABEL UCM OVERLAY 2 BATCH Description Index N Part N 18B 19 20 21 22 23 24 25 26 27 28 29 30 31...

Страница 4: ...substance containing chlorine These products promote corro sion and will pit the stainless steel USE OF THESE PRODUCTS WILL VOID THE WARRANTY Cleaning the GEM3N Satellite To clean the Satellite compo...

Страница 5: ...28 BRACKET STABILIZER LEFT BRACKET STABILIZER RIGHT LABEL FRONT GEM 5N SWITCH ROCKER RED 120VAC KIT WARMER ELEMENT 120V 100W STRAP WARMER ELEMENT LEG 4 ADJUSTABLE 3 8 16 THREAD ITALIAN STYLE Descripti...

Страница 6: ...6 ELECTRICAL SCHEMATIC 10...

Страница 7: ...FRONT TOP RED STP 7 ELECTRICAL SCHEMATIC GEM 5N...

Страница 8: ...3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water...