Program Menus GEMTS/SS Brewer
Program Menus
Temperature
Energy Save Mode
Brew Count Odom
Global Recipes
Banner Name
Access Code
Service Call
Master Reset
Cold Brew Lock
Brew Count Total
From
Program Menus
press > display will show the next feature Global Recipes.
Quality Timer
NON-BREW PROGRAMMING
Temperature
(Factory set to 200ºF)
Press
to Select. Press < or > to move to desired temperature and then
to set. Temperature is programmable from
170ºF to 206ºF in 2-degree increments.
Energy Save Mode
(Factory set to OFF)
Press
to Select, < or > ON, OFF or ON 140ºF ,
to set. When in ON, unit will automatically shut off 4 hours from last
brew. When feature is OFF, unit does not utilize the energy saving mode.
In the ON 140ºF position, temperature lowers to 140ºF, if unit has not brewed in 4 hours. This feature will save energy by
maintaining a lower temperature in the tank in periods of non-operation.
Brew Count Odom
Press
to display total brew cycles. Press EX or Reset.
Quality Timer (
Factory set to OFF)
Press
to select, press < or > to choose desired setting. Range 20 min – 240 min, in 10 minute increments. The timer
does two things. It turns on and off a red indicator light and turns off the warmer element. The indicator light signals when a
predetermined time has expired. The warmer shuts off 12 hours after the indicator light comes on.
Brew Count Total
Press
to Select, Shows total gallons and total brew cycles on the unit. Not resettable.
Cold Brew Lock
. . . (Factory set to 5º )
Press
to select, < or > to select desired setting (CBL 5, 15 or OFF),
to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The
first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for
the Ready to Brew message, however, it will brew at any temperature.
Master Reset
Press
to display Are You Sure?
Then < for Yes, > for No. Brewer factory defaults are then reset.
Service Call
(Phone number Factory set to 1-800-000-0000 X0000)
Press
to display number and change number or < to move place and EX to exit when complete. This number will be
displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code
(Factory set to 1-2-3-4)
Press
to display number and change number, (the number can be changed 1 to 4) or < to move place and EX to exit
when complete.
Banner Name
(Factory set to CURTIS)
Press
to display letters and change letters or < to move place and EX to exit when complete
This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks dis-
ables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.
Warmers Auto – Off
(Factory setting – Disabled)
Press
to Select. Press < or > to adjust from 1 hour to 12 hours. This feature advances in 1 hour increments.
GLOBAL RECIPES
Global Recipes
(Factory set to Gourmet STD)
Press
to select. If selected, press < or > to chose a recipe based on the type of coffee being brewed. Selections are
Gourmet STD, Light Roast, Dark Roast, High Yield, Filter Pack, or Decaf. Press
to select the desired recipe.
Warmers Auto-Off