2.0  Installation

2.1 Terminal Assignments – Main connector (J1)

Curtis enGage™ IV Manual

page 3

Pin# Function

1

Battery V +

2

Common

3

Sender1 input (R, V, I)

4

Sender2 input (R, V, I)

5

Sender3 input (R, V, I, Frequency*)

6

Sender4 input (R, V, I, Frequency**)

7

Switched Input 1

8

Switched Input 2

9

Switched Input 3

10

Switched Input 4

11

Switched Input 5

12

Switched Input 6

13

Keyswitch Input

14

MOSFET output 1

15

MOSFET output 2

16

MOSFET output 3

17

Range Select V + (BDI 
see table in Section 3.0)

18

n/c

19

LCD Heater V +

20

Dimming Control

*Speedometer, Odometer
**Tachometer

Note: Sender 1, 2, 3 and 4 inputs are limited to 60V max. Voltages beyond
that, will damage the instrument.

Содержание enGage IV

Страница 1: ...M MA AN NU UA AL L DIGITAL INSTRUMENTATION...

Страница 2: ...lly consumes 310mA when active The backlight circuit typically consumes 30mA For higher V voltages the operating current is reduced accordingly enGage IV Operating Current mA Without Backlight With Ba...

Страница 3: ...s Only to 80 C Thermal Shock As per SAE J1455 section 4 1 3 2 Applicable To Enclosed Units Only to 80 C Humidity 95 RH non condensing at 38 C Applicable To Enclosed Units Only as per SAE J1455 section...

Страница 4: ...requency 7 Switched Input 1 8 Switched Input 2 9 Switched Input 3 10 Switched Input 4 11 Switched Input 5 12 Switched Input 6 13 Keyswitch Input 14 MOSFET output 1 15 MOSFET output 2 16 MOSFET output...

Страница 5: ...ounting Enclosed unit snaps into panel cutout using molded in fingers An optional mounting bracket Curtis P N 17644307 can be used for additionsal support Module units are attached via screw holes in...

Страница 6: ...Following a power up sequence the OEM logo if applicable will be displayed Once the start up process is complete the specified default normal monitoring screen will appear 2 6 1 enGage IV Menu System...

Страница 7: ...U mode Press UP DN to navigate ENTER to select UP DN to change ENTER to accept Sub menu 111 11 11 SET MM 1 INTERVAL 11 12 SET MM 2 INTERVAL 11 13 SET MM 3 INTERVAL 11 1x EXIT Sub menu 112 11 21 RESET...

Страница 8: ...to the main menu by utilizing the up down arrows on panel and select Exit 2 6 4 3 Set Clock Starting from the main menu choose Set Clock then Set Clock again Once the left button is pressed to select...

Страница 9: ...scribed earlier 3 1 Auto range BDI Curtis enGage IV has an operating voltage range for V from 12 to 80 VDC 25 The source to which pin J1 17 is connected will configure the instrument for the correct B...

Страница 10: ...strument voltage range selected does not match battery voltage Range Select V connected to wrong terminal Will Not Reset Instrument voltage does not match battery voltage Battery not fully charged Bat...

Страница 11: ...roper voltage Stays At Sender or Sender Connection Problems Maximum Minimum Sender connected to wrong terminal Incorrect sender used Maintenance Function Problem Possible Cause Will Not Reset Procedur...

Страница 12: ...ions subject to change without notice 2004 CURTIS INSTRUMENTS INC 53040 REV A 2 04 CURTIS INSTRUMENTS INC 200 Kisco Avenue Mt Kisco New York 10549 USA Tel 914 666 2971 Fax 914 666 2188 www curtisinstr...

Отзывы: