PROGRAMMING GUIDE
PG9
Programming Options (cont.)
Service Call -
sets the service phone number that appears on the display when the UCM detects a SENSOR
ERROR or WATER ERROR . Once accessed, press
Ż
or
Ź
to choose the number to be changed. Then press
~
repeatedly
to change the number value. Press
Ż
or
Ź
to choose the next number to change or choose exit
and press
~
.
Access Code -
TFUTUIFBDDFTTDPEFFOUFSFEUPBDDFTTQSPHSBNNJOHNPEF UIFGBDUPSZEFGBVMUJT
Once accessed, press
Ż
or
Ź
to choose the number to change. Then press
~
repeatedly
to change the
OVNCFSWBMVF SBOHFJTUP1SFTT
Ż
or
Ź
to choose the next number to change or choose exit and
press
~
.
Banner Name -
changes the banner name that appears on the display (the factory default is
Curtis
/P
CBOOFSOBNFBQQFBSTXIFOBMMCMBOLTBSFFOUFSFE0ODFBDDFTTFEQSFTT
Ż
or
Ź
to choose the letter to
change. Then press
~
repeatedly
to change the letter value. Press
Ż
or
Ź
to choose the next letter to change
or choose ex and press
~
to exit.
Warmer Auto-Off -
(Alpha
®
TFSJFTVOJUTPOMZBEKVTUTUIFMFOHUIPGUJNFUIBUFMBQTFTCFGPSFUIFXBSNFS T
TIVUPGGBVUPNBUJDBMMZ5IFSBOHFJT0GGUPIPVST UIFGBDUPSZEFGBVMUJT0GG0ODFBDDFTTFEQSFTT
Ż
or
Ź
to
adjust the number of hours. Then press
~
to set and exit.
P-Maintenance -
UVSOTPOPGGBOEBEKVTUTUIF1.BJOUFOBODF QSFWFOUJWFNBJOUFOBODFCSFXNPOJUPS
UIFGBDUPSZEFGBVMUJT0''8IFO0/UIF6$.NFBTVSFTUIFOVNCFSPGHBMMPOTCSFXFECFGPSFUIF
1.BJOUFOBODFSFNJOEFSBQQFBSTPOUIFEJTQMBZ5IFSBOHFJT0GGUPHBMMPOT0ODFBDDFTTFEQSFTT
Ż
or
Ź
to choose the desired setting, then, press
~
to exit.
Beeper On/Off -
turns the beeper that is heard each time a button is pressed on or off (the factory default is
0/0ODFBDDFTTFEQSFTT
Ż
or
Ź
to choose the desired setting. Then, press
~
to exit.
Pulse Brew -
TFMFDUTUIFQVMTFCSFXQBUUFSO 1SF*OGVTJPONVTUCFPGGUPBDDFTTUIFGBDUPSZEFGBVMUJT$5IF
QVMTFCSFXQBUUFSOTFMFDUFEiUVOFTwPSDIBOHFTUIFnBWPSPGUIFDPGGFF0ODFBDDFTTFEQSFTT
Ż
or
Ź
to
choose the desired setting. Then, press
~
to exit.
8IFO1VMTF#SFXJTPO$PME#SFX-PDLJTTFUXJUIJO'BOE$PME#SFX-PDLBOE1SF*OGVTPO
disappear from the list of program selections.
Pulse Brew Guidelines
•
'JMUFSQBDLUZQFDPGGFFTUZQJDBMMZFYUSBDUCFUUFSXJUIUIF"BOE#QVMTFTFUUJOH
•
%FDBGGFJOBUFEDPGGFFTUZQJDBMMZFYUSBDUCFUUFSXJUIUIF#QVMTFTFUUJOH
•
)JHIZJFMEDPGGFFTUZQJDBMMZFYUSBDUCFUUFSXJUIUIF$QVMTFTFUUJOH0GDPVSTFBOZPGUIF"#PS$
TFUUJOHTNBZCFVTFEUPTVJUZPVSUBTUFQSPmMF
• Settings D and E are manual pulse counts.
8$8$130(3"..*/((6*%&ø
#
Setting
Description
A
Starts at beginning of brew cycle. 4 cycles of 10 seconds on and 5 seconds off, then on until end of brew cycle.
B
Starts towards end of brew cycle (without drip-out mode). 4 cycles of 5 seconds off and 4 cycles of 10 seconds on.
Ends when brew cycle ends.
C
Starts at beginning of brew cycle. 5 cycles of 25 seconds on and 10 seconds off, then on until end of brew cycle.
D
Manually set. Starts 30 seconds after brew cycle starts. Number of pulses is adjustable from 1 to 10. Pulse on time
and off time are both adjustable from 5 to 60 seconds.
E
Manually set. Starts at beginning of brew cycle. Number of pulses is adjustable from 1 to 24. Pulse on time and off
time are both adjustable from 1 to 150 seconds.