![Curtis CT Series Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/curtis/ct-series/ct-series_instruction-manual_2700238005.webp)
CT SERIES
CAP 410
PAGE 3
START-UP PROCEDURES
OIL RECOMMENDATION
Use Genuine
CURTIS
L
UBE
P
LUS Lubricants.
Specially
formulated for Curtis Reciprocating Air Compressors. Non-
Detergent type with anti-foam, anti-rust and oxidation
inhibitors.
Recommended
ISO68 RC-1000
Premium Reciprocating
Compressor Lubricant,
Part no. VO411-3
, 12-quart case or
VO411-2, 4 gallon case.
Recommended
ISO100 RC-1000A
Premium Reciprocating
Compressor Lubricant
Part no. VO421-3
, 12-quart case or
VO421-2, 4 gallon case.
CURTIS
L
UBE
P
LUS Lubricants are available through
your authorized Curtis distributor.
If the compressor is equipped with an automatic start-stop
control (with pressure switch unloading), it is automatically
unloaded upon starting, and will automatically load after
attaining running speed. Close the disconnect switch and
start the compressor. Observe the direction of rotation,
which should be counterclockwise when viewed from the
flywheel side of the compressor on all models. For single-
phase units, the direction of rotation is determined by the
motor nameplate instructions, and is adjusted at the factory.
For three-phase units, if the rotation is incorrect, stop the unit
and interchange any two of the three wires to the motor at
the disconnect switch. This will reverse the direction of
rotation of the motor and compressor.
PREVENTIVE MAINTENANCE
TURN OFF POWER BEFORE
SERVICING!!!
A good maintenance program will add years of service to
your air compressor. The following is recommended as a
minimum maintenance program.
(DO NOT OPERATE WITHOUT BELT GUARD)
LUBRICATION
1. For proper lubrication the compressor shall not be
operated below the minimum or above the maximum R. P.M.
recommended for the various models.
2. Maintain oil level mid-way between the upper and lower lines
of the crankcase sight gage.
NOTE ILLUSTRATION:
3. Stop compressor to add and gauge oil.
4. Do not fill above the upper line and do not operate compressor
with oil level below the lower line.
DO NOT OVER FILL
5. Change oil at the first 100 hours of operation and 1000 hours
thereafter, or as required. It may be necessary to change oil
more frequent due to abnormal humid and contaminated
conditions.
DAILY MAINTENANCE SCHEDULE
1. Check and maintain oil level at centerline of sight glass and
add oil as necessary.
2. Drain condensate from receiver unless it is equipped with an
automatic tank drain, in which case the drain should be
checked weekly to see that it is operating. See automatic tank
drain instructions.
3. Check for unusual noise or vibration (See "Trouble Shooting".)
WEEKLY
1. Clean the air filters. A clogged air filter can seriously affect the
efficiency of the compressor and cause overheating and oil
usage.
2. Clean all external parts of the compressor and driver. Be sure
to clean the intercooler-finned surface on two-stage
compressors. A dirty compressor will cause abnormally high
discharge temperature and resulting oil carbonization on
internal valve components
3. Check the safety valve manually (by pulling ring or lever) to
see that it is not stuck.
INITIAL – 100 HOURS OR 30 DAYS
1. Change oil.
2. Check drive belt tension and tighten if needed.
MONTHLY
1. Inspect the entire air system for leaks.
2. Inspect condition of oil and change if necessary.
3. Check drive belt tension and tighten if needed.
EVERY 3 MONTHS OR 1,000 HOURS OF OPERATION.
1. Change oil.
2. lnspect valves. Clean the carbon from valves and head if
necessary.
3. Check and tighten if necessary all bolts, nuts, etc.
4. Check unloader operation.
*CHECKING BELT TENSION
The v-belt(s) should be adjusted so that a declination of about 3/8
– 1/2 inch will be obtained when it is pushed by a finger at the
middle point as shown in Figure 1.
CAUTION: Over tightening the v-belt(s) will result in
overloading of the motor and belt failure, while a loose
belt will be slipping and resulting in an unstable speed,
overheating the belt and high amp draw.
WARNING: Read and understand supplement LV-474 before installing and operating the compressor.
Содержание CT Series
Страница 8: ...CT SERIES CAP 410 EXPLODED VIEW VERTICAL 5HP 60 GALLON MODEL 555VT6 PAGE 6 ...
Страница 10: ...CT SERIES CAP 410 PAGE 8 EXPLODED VIEW VERTICAL 5HP 80 GALLON MODEL 555VT8 ...
Страница 12: ...CT SERIES CAP 410 PAGE 10 EXPLODED VIEW VERTICAL 7 1 2HP 80 GALLON MODEL 755VT8 ...
Страница 14: ...CT SERIES CAP 410 PAGE 12 EXPLODED VIEW VERTICAL 7 1 2HP 80 GALLON MODEL 775VT8 ...
Страница 16: ...CT SERIES CAP 410 PAGE 14 EXPLODED VIEW VERTICAL 10HP 80 GALLON MODEL 1075VT8 ...
Страница 18: ...CT SERIES CAP 410 PAGE 16 EXPLODED VIEW HORIZONTAL 7 1 2HP 120 GALLON MODEL 775HT12 ...
Страница 20: ...CT SERIES CAP 410 PAGE 18 EXPLODED VIEW HORIZONTAL 10HP 120 GALLON MODEL 1075HT12 ...
Страница 22: ...CT SERIES CAP 410 PAGE 20 EXPLODED VIEW HORIZONTAL 13HP HONDA ...