![Curtis Chill-X Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/curtis/chill-x/chill-x_user-manual_2699113023.webp)
21 Set the mixing bowls back in place.
Make sure that the lip on the bottom
of each bowl rests inside the front
trim on the top of the chassis.
22 Replace the lids.
23 Remove and discard the existing tap
seals from the tap handle assemblies.
CLEANING INSTRUCTIONS - CBFX
CI34
CFBX, CLEANING INSTRUCTIONS
082619J
Preventive Maintenance (cont.)
22
24 Install the new tap seals.
25 Lubricate the tap seal and the handle
mounting slots using food grade
lubricant.
26 Prepare the tap assembly for
attachment. Insert the top of the
spring into the hook on the bowl, as
shown. Insert the red rubber seal on
the back of the tap lever into the tap
hole on the bottom of the bowl. Line
up the middle pins on the tap lever
with the mounting slots.
27 Attach the tap handle assemblies.
Push in with your thumb on the center
of each tap lever handle until the
assembly pops into place.
continued...
23
21
Old tap
seal
c
d
e
18 Install new auger seals on the front of
each drum.
19 Reinstall the augers. Rotate each
auger until it engages completely.
20 Lubricate the inner surface on each
bowl seal with food grade lubricant
(Curtis Part # WC-4916). Install a
bowl seal on the back of each bowl.
Food Grade
Lubricant
20
19
Auger
seal
18
Auger
Bowl
seal
24
Food Grade
Lubricant
25
Bowl
Tap
seal
26
Put spring
into hook
Mount
Red seal
Line up as
shown
27
Push in
here
DO NOT
push here