background image

 

Hurricane ES Owner’s Manual

 

 

12 

 

 

 

 

 

4.0

 

Principles of Operation-   

H

H

u

u

r

r

r

r

i

i

c

c

a

a

n

n

e

e 

E

E

S

S

 

This machine consists of a motor/blower assembly, high voltage power supply, charging 
ring and electrode, blower housing, a nozzle, formulation tank and metering valve.  The 
blower is a two-stage centrifugal compressor driven by a universal motor operating at a 
speed of 20,000 rpm.  The blower moves a large amount of air through the nozzle 
system.  The nozzle has six (6) stationary fins, which direct the air to create a swirling 
effect of the air mass as it leaves the nozzle.  In the center of this exiting swirling air, a 
liquid  supply  spout  tube  injects  formulation.    The  liquid  is  delivered  to  the  nozzle  by  a 
negative  pressure  at  the  nozzle  caused  by  the  exiting  air  mass.    The  flow  rate  is 
controlled  by  a  one  turn  precision  metering  valve  located  at  the  formulation  tank.  
Generally, the sizes of the output droplets increase with increasing flow rates and with 
increasing viscosity of the liquid being dispensed.  

After  the  nozzles  shear  the  formulation  into  billions  of  droplets,  the  droplets  are 
dispersed into the atmosphere.   As the droplets  exit the nozzles they pass through an 
“electrostatic  ion  field”.    This  field  is  created  using  the  combination  of  a  high  voltage 
power supply, an emitting electrode and charging ring (Collector).  The result is billions 
of  electrostatically  charged  droplets  that  gravitate  to  neutral  objects  to  form  a  uniform 
coverage.    The  various  components  are  identified  in  the  fluid  systems  and  major 
components diagrams. 

 

Содержание Aire-Mate Hurricane ES 3001-5

Страница 1: ...H Hu ur rr ri ic ca an ne e E ES S Electrostatic ULV Mist Sprayer O Ow wn ne er r s s M Ma an nu ua al l ...

Страница 2: ...nt environmentally responsible machine This is only possible with the help of many talented people and from suggestions from our customers If you have any questions or suggestions concerning our products please contact us at the address shown below All Curtis Dyna Fog products are tested and calibrated at the factory To ensure safe and responsible spray applications please be sure to read and unde...

Страница 3: ...t of all liabilities of Seller in any respect to the machines THE FOREGOING WARRANTY AND THE OBLIGATIONS AND LIABILITIES OF SELLER THEREUNDER ARE EXCLUSIVE AND IN LIEU OF AND PURCHASER HEREBY WAIVES ALL OTHER REMEDIES WARRANTIES GUARANTEES OR LIABILITIES EXPRESS OR IMPLIED ARISING BY LAW OR OTHERWISE INCLUDING WITHOUT LIMITATION ANY OBLIGATIONS OF THE SELLER WITH RESPECT TO FITNESS MERCHANTABILITY...

Страница 4: ...nsect Control 13 5 2 Odor Control 14 5 3 Disinfecting 14 6 0 Maintenance 15 6 1 Replacing the 3 Prong Electrode 15 6 2 Removing the Metering Valve Accessing the Formulation Filter 16 7 0 Troubleshooting 17 8 0 Electrical Schematic 18 9 0 Hurricane ES Exploded Parts Diagram 19 22 9 1 Hurricane ES Parts Listing 20 21 9 2 Hurricane ES Valve Assembly Diagram and Parts Listing 22 10 0 Hurricane ES Carr...

Страница 5: ...ponents Diagram H Hu ur rr ri ic ca an ne e E ES S Liquid Metering Valve Formulation Tank Fill Cap Power and Electrostatic Indicator Light 3 Air Assist Nozzles Electrostatic Charging Ring Collector Adjustable Locking Handle High Capacity Blower ...

Страница 6: ...ing WARNINGS before operating the machine UNDERSTAND THESE SAFETY PRECAUTIONS BEFORE OPERATING MACHINE FAILURE TO PROPERLY FOLLOW THESE PRECAUTIONS MAY LEAD TO A FIRE EXPLOSION OR ELECTRICAL SHOCK HAZARD WARNING Always have the machine serviced by a professional qualified representative Never attempt to service the machine or access its internal components while it is plugged into an electrical ou...

Страница 7: ...may cause an electrical shock if not properly grounded Always use a three 3 prong grounded extension cord at the ratings shown in the table when using an extension cord In addition always maintain contact with the handle during operation to ensure proper grounding Always hand carry the machine during operation so that your hand remains in contact with the grounding strip located beneath the carryi...

Страница 8: ... wood and plastics are generally non conductive at the working voltages of this machine Metals are usually conductive Do not probe inside the machine Extension cords must be properly sized and rated for the voltage current and LENGTH of an individual cord Consult the nameplate current and voltage rating of your machine and the marked rating of the extension cord A single extension cord only should...

Страница 9: ...While operating the machine always carry the machine by the carrying handle to ensure that you are properly grounded 5 Proper and Improper Use The following rules apply to the operation of this machine 2 2 Read the entire manual before operating the machine and pay particular attention to all CAUTIONS AND WARNINGS Only use water base formulations with this machine Store formulation in its original...

Страница 10: ...dding or removing parts Do not restrict the motor blower inlet area Do not tamper with the output nozzle or 3 prong electrode and charging ring Collector Do not allow the machine to operate unattended Do not stand in water or hold over water while operating machine Do not allow the power cord or extension cord to be submersed in water Do not use outdoors when it s raining Do not apply more than on...

Страница 11: ... being dispensed See table 2 for particle size vs valve setting flow rate Hurricane ES Model 3001 5 120 VAC Hurricane ES Model 3001 6 240 VAC Motorized Blower High efficiency Motor Blower Brush Life Approximately 1000 hours Electrostatic Power Supply 120 or 240 Volt AC Current Draw 120V AC 220V AC 6 85 Amps 3 40 Amps 50 60 Hz 50 60 Hz Nozzle Type Professional grade electrostatic 3 nozzle air assis...

Страница 12: ...d is delivered to the nozzle by a negative pressure at the nozzle caused by the exiting air mass The flow rate is controlled by a one turn precision metering valve located at the formulation tank Generally the sizes of the output droplets increase with increasing flow rates and with increasing viscosity of the liquid being dispensed After the nozzles shear the formulation into billions of droplets...

Страница 13: ...r liquids with a lower viscosity atomize easier and flow at higher rates Refer to the table below for approximate flow rates and droplet sizes at the various valve settings Droplet sizes are shown in microns VMD Volume Median Diameter The VMD is an industry standard and represents the middle point of the spray droplet spectrum of the liquid being applied Important To maximize electrostatic efficie...

Страница 14: ...ty no cm3 1 93 7 hours 19120 0 5 3 7 hours 152 0 10 56 minutes 19 2 20 14 minutes 2 38 50 135 seconds 0 150 100 36 seconds 0 0192 The recommended droplet for Mosquito control is 10 20 Microns For Fly control approximately 30 Microns For Bedbugs spiders and other crawling insects where a slight residual is desired 20 40 Microns droplets are affective depending on insect type and type of formulation...

Страница 15: ...ition settings are as follows Position Flow rate Droplet Size VMD 1 6 oz min 177 ml min 10 20 2 7 5 oz min 222 ml min 20 30 9 5 oz min 281 ml min 30 50 Flow rates shown are approximate and will vary depending on liquid viscosity and temperature Important Always spray responsibly This device is designed to dispense formulations in a SPRAY Cold Fog Many of the formulations which may be dispensed wit...

Страница 16: ...it Each machine is shipped with one spare electrode Electrode P N 62172 6 1 Replacing the 3 Prong Electrode Step 1 Depending on various operating conditions after several hours of operation the 3 prong electrode may begin to show signs of wear Visually inspect the electrode after every 25 hours of operation and look for signs of wear around the edges If the electrode becomes worn or damaged procee...

Страница 17: ...sure that the valve body is seated completely down inside the cavity of the plastic tank Use a small hammer to press the drive rivet back into the formulation tank The drive rivet serves as a stop for the valve assembly as well as a retainer to keep the valve assembly from coming out of formulation tank 2 Once you have the drive rivet back in place turn the valve stem clockwise until it stops When...

Страница 18: ...blower Check power cord connections and inspect cord for damage Replace power cord if necessary Replace the blower motor and motor gaskets Replace switch Have unit serviced by a qualified representative Spray is dripping from the front of the machine Too high of flow rate Reduce the metering valve setting Static shock occurs when touching Charging Ring Collector or 3 prong electrode Emitter or met...

Страница 19: ...Hurricane ES Owner s Manual 19 8 0 Electrical Schematic Diagram for 110V and 220V ...

Страница 20: ...Hurricane ES Owner s Manual 20 9 0 Hurricane ES Exploded Parts Diagram ...

Страница 21: ...Hurricane ES Owner s Manual 21 9 1 Hurricane ES Exploded Parts List ...

Страница 22: ...ORMATION 17 1 20180 3 STRAIN RELIEF 110V 1 20180 4 STRAIN RELIEF 220V 18 1 62143 GROUND STRIP 19 1 62367 NUT 3 8 16 SQUARE 20 1 62053 1 HAND STOP SLOTTED 21 1 62162 SCREW 10 12 X 3 4 SHWH 22 1 62186 BUTTON ELECTRODE SUPPORT 23 1 62441 SCREW 10 3 4 BUTTON 24 1 62172 ELECTRODE 3 PRONG 25 1 62170 RING STUD AY 26 3 62171 SPACER NYLON 196 ID X 312 OD X 25 LONG 27 1 86819 1 SWITCH LIT ROCK 110V 1 86819 ...

Страница 23: ... Item Part Number Description 1 32692 Nut Packing 2 32690 Washer Packing 3 32691 Washer Brass 4 62319 1 Stem Metering Valve 5 62180 Valve Body Brass 6 10100 110 O Ring 7 62227 1 Tube Blue 3 16 ID X 5 16 OD 8 80408 Filter Long tapered 130 Microns APPLY LUBRICANT TO THREADS AND O RING ...

Страница 24: ...Hurricane ES Owner s Manual 24 10 0 Hurricane ES Carrying and Storage Bag Large pouch for storing extension cord owner s manual tools etc P N 62188 Bag Machine Carrying Storage ...

Страница 25: ... s Manual 25 11 0 Hurricane ES Labels Label Logo P N 62146 Label Flow Caution P N 62194 Label Flow Rate Indicator P N 62198 Label Shipping Carton P N 62193 Label Caution P N 62197 Label Warning Read the Manual P N 62196 ...

Страница 26: ...Hurricane ES Owner s Manual 26 12 0 NOISE LEVEL COMPARISON CHART HURRICANE ES Label Warning Electrostatic P N 62191 choking ...

Страница 27: ...Hurricane ES Owner s Manual 27 ...

Страница 28: ...Hurricane ES Owner s Manual 28 Curtis Dyna Fog Ltd PO Box 297 17335 US Hwy 31 North Westfield Indiana 46074 USA www dynafog com www airemate com Rev Mar 2012 ...

Отзывы: