15
Injector Size Table
Burner Injector Values (Total consumption 749 gr/h)
According to the Gas Type (Total Power 10.3 kW)
LPG
Natural Gas
G30 / G31
28-30 mBar
G 20
20 mBar
Large Burner (Fast)
Injector
mm
0.850
1.150
Nominal Rating
kW
3
2.75
Consumption
218.1 gr/h
261.9 lt/h
Standard Burner
Injector
mm
0.650
0.970
Nominal Rating
kW
1.75
1.75
Consumption
127.2 gr/h
166.7 lt/h
Small Burner (Simmer)
Injector
mm
0.500
0.720
Nominal Rating
kW
1
1
Consumption
72.7 gr/h
95.2 lt/h
Oven Burner
Injector
mm
0.760
1.200
Nominal Rating
kW
2.8
2.8
Consumption
203.6 gr/h
266.7 lt/h
Grill Burner
Injector
mm
0.680
1.100
Nominal Rating
kW
2.2
2.2
Consumption
160 gr/h
209.5 lt/h
Lubrication of the Gas Taps
A Gas Safe Registered Engineer must lubricate the gas taps.
Electrical Connection
• This cooker is fitted with a BS1363 moulded plug. The mains plug
must remain accessible when the cooker is in its place of use.
• If the installation requires any alterations to the domestic electric
system, this must be performed by a qualified electrician.
• The mains cable should be routed away from any hot parts.
• If the mains cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard. Ensure that the Earth lead is of
sufficient length to remain connected after the Live and
Neutral wires are removed if the lead is pulled.
• Ensure all terminal screws are adequately tightened. Do not
over tighten as you may risk damaging the screw threads.
L
N
Live (Brown)
Earth
(Green/Yellow)
Neutral (Blue)
Cord Clamp
* All images are for indication only; please refer to your individual unit for actual item.
• All intervention regarding installation maintenance and conversion of the appliance must be fulfilled
with original factory parts.
• The manufacturer declines any liability if these correct parts are not used.
Currys Essentials Free Standing GAS Cooker CFSG60W17 Manual.indd 15
Currys Essentials Free Standing GAS Cooker CFSG60W17 Manual.indd 15
20/01/2021 17:42
20/01/2021 17:42