system status or in a galley/passenger service area for use by the cabin attendant depending on
the particular aircraft installation and regulatory requirements.
The Remote Test (pin 7) and Remote Reset (pin 8) switch inputs to the unit must be supplied by
normally open, momentary switches. The switches may be mounted in the cockpit for flight
crew use or in a galley/passenger service area for use by the cabin attendant depending on the
particular aircraft installation and regulatory requirements.
The Remote Switch Ground (pins 9 & 10) shall be utilized for the ground side of the momentary
switches.
Figure 4 AGFCI Unit J2 Connector Layout
NOTE: "Figure 6 Typical Annunciator Switch Interconnect" illustrates a possible interface
utilizing the Vivisun LED series switches. For additional information or other configurations
contact Aerospace Optics, Inc. at 1-888-VIVISUN (817-451-1141). Recommended part numbers
are listed in "Table 2 Accessories Not Supplied".
**Mating face view of socket layout** Aircraft P2
Connector Wire Side Layout Is Opposite