1.

 

Before removing your Prime Chiller from the box, please note any exterior shipping damage 

to  the  box.  It  is  strongly  recommended  to  keep  the  box  and  packaging  material  in  the 
unlikely event there is shipping damage or service is required.

2.

 

Remove  the  chiller  and  controller  from  the  box  and  inspect  thoroughly  for  any  signs  of 
damage, even if the box does not show damage. If you notice any damage (cracked or bent 
cover, damaged condenser, fins, etc...) please stop and contact your dealer immediately.

3.

 

Make sure the chiller is placed on a firm, level surface in a location that has plenty of ventilation 

and will not be exposed to salt or saltwater. Do not use an extension cord for the chiller or  
the thermostat.

The requirements for ventilation are:

a) Back/Front: Condenser (radiator) requires at least 18” clearance to allow air into the chiller.
b) Sides: Requires at least 6” clearance to allow for proper air flow. 
c) Chiller must not be placed in a closed closet or cabinet.  If placing chiller under a cabinet, the 

cabinet MUST have a back opening at least 30" wide x 30" high for adequate ventilation.

d) The warm air from the chiller must be completely evacuated from the chiller location. A fan 

may be necessary to draw warm air away from the chiller. The maximum operating temperature 
is 95 F.

Installation:

4. The chiller includes both 3/4" and 5/8" hose barb fittings.  Insert desired hose connector into 

compression cap.

5. Place barb fitting onto inlet or outlet and tighten compression cap.  Ensure that the gasket 

fits snug between the barb fitting and chiller.

6.  Slide  hose  clamps  onto  hose.    Attach  hose  to  inlet/outlet  barb  fitting  and  tighten  hose 

clamp.

7. Before turning on chiller, ensure the following:

a) The chiller must have adequate water flow for proper operation.

  Model 

HP

  

 

Min/Max Flow

 

2645  

1/4  

 

5-10 gpm

 

2646  

1/3  

 

6-12 gpm

b) Make sure the pump will operate normally without any blockage.
c) Make sure the chiller is plugged into a GFCI protected 110V power outlet.

7. Turn on water pump and check for leaks.  IMPORTANT: Do Not Run Chiller without water 

flow.  Doing so may damage evaporator.

8.  Set  the  temperature  controller  to  the  desired  temperature  as  instructed  in  Programming 

Chiller installation