Current 2645 Скачать руководство пользователя страница 5

WWW.CURRENT-USA.COM

Setting the temperature setting

1. Press the SET Key - the LCD display will automatically display the current set point.  

2. Press Up "<"  button to increase temperature or press Down ">"button to decrease temperature to your 
desired setpoint.  The temperature must be set between 60-85 degrees F.  

3. Confirm set temperature by pressing SET button again or waiting for 8 seconds.  The current aquarium 
temperature will then be displayed when chiller begins to operate in normal mode.

Please Note:  The chiller has a built-in protection mode that  can delay the cooling mode  operation for 
up to three (3) minutes.    

Sensor Calibration & Temperature differential

The temperature sensor should not normally need to be calibrated, however when using a additional 
electronic digital thermometer the sensor can be calibrated to match the thermometer.  To calibrate:

1. Press the SET key for 10 seconds, the chiller will automatically go into calibration mode. 

2. Default is set at "00", press Up "<" to change the tempe1 F and higher, press Down ">" to 
change the temperature -1 F and lower.  Therefore if the chiller reads 80 degrees and the calibration 
requires it to read 78 degrees, simply go into the calibration mode and depress the Down "<" to -2F.

3. Press SET again and to go into the temperature differential mode.  To bypass this mode, simply hit 
SET key again.

NOTE:  This  unit  is  preset  to  a  temperature  differential  of  2  degrees  F.    We  DO  NOT  recommend 
changing the differential.

4. If changing the differential is required, simply press the "<" up key to change from 2 degrees F to a 
higher set point.

5.  Press  SET  key  once  the  desired  differential  is  reached.    The  chiller  will  automatically  move  into 
normal mode operation.

using the integrated heater port

This  Prime  chiller  features  a  dual  stage  controller  and  an  outlet  located  on  the  back  for  use  with 
aquarium heaters.  If using an aquarium heater (not included) with this unit, simply plug the heater 
into the back of the chiller and the chiller will automatically energize the heater port when the water 
temperature reaches 2 degrees F below the set temperature.

Please Note: This port is to be used with aquarium heaters up to 300 watts only.  We ONLY recommend 
using UL listed aquarium heaters.

Temperature Controller

specifications/Installation

Содержание 2645

Страница 1: ...COM WWW CURRENT USA COM Inline Chiller Instructions for Models 2645 2646 Warning and Safety Instructions Page 2 Chiller Installation Page 3 Temperature Controller Programming Page 5 Warranty Page 7 P...

Страница 2: ...be plugged in if there is water on parts not intended to be wet Do not operate any appliance if it has a damaged cord or plug or if it is malfunctioning or has been dropped or damaged in any manner D...

Страница 3: ...e warm air from the chiller must be completely evacuated from the chiller location A fan may be necessary to draw warm air away from the chiller The maximum operating temperature is 95 F Installation...

Страница 4: ...y for optimum performance and efficiency Chiller installation Digital Temperature Controller Maintenance Warning always disconnect chiller before cleaning or performing any maintenance Monthly Vacuum...

Страница 5: ...ange the temperature 1 F and lower Therefore if the chiller reads 80 degrees and the calibration requires it to read 78 degrees simply go into the calibration mode and depress the Down to 2F 3 Press S...

Страница 6: ...te for a minimum of 48 hours for it to reach the desired setpoint If the chiller turns on off in a repeated cycle this indicates that 1 The chiller is over heating Ensure that enough air flow is flowi...

Страница 7: ...urrent USA Inc does not warrant any products that are not Current USA Inc products This warranty does not apply if the product has been damaged by accident abuse misuse or misapplication or if the pro...

Отзывы: