TENSPros

      

  

TWIN STIM

®

 III 

 

INSTRUCTION MANUAL

Содержание InTENSity Twin Stim III

Страница 1: ...T E N S P r o s TWIN STIM III INSTRUCTION MANUAL ...

Страница 2: ...r notice Amendments may however be published in new editions of this manual All Rights Reserved Rev V1 1 2010 United States Federal Law restricts this device to sale by or on the order of a physician or licensed practitioner Declaration of conformity Current Solutions LLC declares that the device complies with following normative documents IEC60601 1 IEC60601 1 2 I EC60601 2 10 IEC60601 1 4 ISO109...

Страница 3: ... 4 1 Battery 4 2 Connect electrodes to lead wires 4 3 Connect lead wires to device 4 4 Electrodes 4 5 Turn ON 4 6 Select the Therapeutic Mode 4 7 Steps to set a new program 4 8 Adjust Channel Intensity 4 9 Safty lock feature 4 10 Stop the treatment 4 11 Turn OFF 4 12 Low battery indicator 5 PROGRAM 6 CLEANING AND CARE 6 1 Tips for skin care 6 2 Cleaning the device 6 3 Electrodes 6 4 Cleaning the E...

Страница 4: ...though pain is a necessary warning signal of trauma or malfunction in the body nature may have gone too far in its design Aside from its value in diagnosis long lasting persistent pain serves no useful purpose Pain does not begin until the coded message travels to the brain where it is decoded analyzed and then reacted to The pain message travels from the injured area along the small nerves leadin...

Страница 5: ...st EXPLANATION OF EMS Electrical Muscle Stimulation EMS is an internationally accepted and proven way of treating muscular injuries It works by sending electronic pulses to the muscle needing treatment this causes the muscle to exercise passively It is a product derived from the square waveform originally invented by John Faraday in 1831 Through the square wave pattern it is able to work directly ...

Страница 6: ...does with normal muscular activity 1 3 Indication for use Stimulator may be used for For Transcutaneous Electrical Nerve Stimulator therapeutic modes TENS 1 Symptomatic relief of chronic intractable pain 2 Post traumatic pain 3 Post surgical pain For Electrical Muscle Stimulation Neuromuscular Stimulation therapeutic mode EMS 1 Relaxation of muscle spasm 2 Increase of blood flow circulation 3 Prev...

Страница 7: ...T E N S P r o s 1 4 Contraindications 1 5 Warnings Cautions and Adverse Reactions 7 ...

Страница 8: ...T E N S P r o s 8 ...

Страница 9: ...T E N S P r o s out of reach of children you are in any doubt whatsoever CAUTIONS ...

Страница 10: ...physician if problems persist 19 This device should not be used while driving operating machinery close to water or during any activity in which involuntary muscle contractions may put the user at undue risk of injury 20 Never use the device in rooms where aerosols sprays are used or pure oxygen is being administered 21 Do not use it near any highly flammable substances gases or explosives 22 Do n...

Страница 11: ...T E N S P r o s Adverse Reactions ...

Страница 12: ...T E N S P r o s 2 Presentation 2 1 Front and Rear Panel 12 ...

Страница 13: ...of the waveform in the current treatment program ss the button to enter setting and Press button and hold for cover for user access 2 2 LCD display or Displays the cycle time for y for channel 1 CH1 Display of S waveform of contraction raction working time 13 ...

Страница 14: ... channel 2 CH2 Display of waveform pulse rate or EMS waveform of relaxation time in setting state 13 Displays channel 2 14 EMS waveform of relaxation time 15 Displays the treatment time or EMS waveform of ramp up and ramp down time 16 Low battery indicator ...

Страница 15: ... with a relative humidity of 30 75 atmospheric pressure from 700 to 1060 Hpa Storage conditions 10 C to 50 C 14 to 122 with a relative humidity of 10 90 atmospheric pressure from 700 to 1060 Hpa Dimensions 4 5 2 55 0 9 inches L W H Weight 0 28 lbs With battery Tolerance There may be a 5 tolerance of all setting and 10 tolerance of output of intensity Electrode Detection Function The amplitude leve...

Страница 16: ...the setting value Pulse Width Modulation M The pulse width is automatically varied in a cycle time The pulse width is decreased from its original setting to 60 in setting cycle time and then increased from 60 to its original setting in nest setting cycle time In this program pulse rate 1 to 150Hz pulse width 50 to 300us and cycle time 5 to 30 sec are fully adjustable Pulse Rate Modulation M1 The p...

Страница 17: ... both channels occurs synchronously The ON time including Contraction Ramp Up and Ramp Down time ON TIME Contraction Ramp up Ramp down Alternate A The Stimulation of the CH2 will occur after the 1st operation of CH1 is completed In this program The ON time including Contraction Ramp Up and Ramp Down time The OFF Time should be equal or more than the ON Time ON TIME Contraction Ramp up Ramp down OF...

Страница 18: ...T E N S P r o s 3 3 The waveforms of the stimulation programs Burst B Normal N Pulse Width Modulation Pulse Rate Modulation cycle time ...

Страница 19: ... Synchronous S Alternate A Delay D 4 Instruction for use 4 1 Battery 4 1 1 Check Replace the 9V ALKALINE battery Over time in order to ensure the functional safety of device the battery must be periodically changed 19 ...

Страница 20: ...kin eyes and mucus membranes Rinse the affected spots with lots of clear water immediately and contact a physician right away 3 Battery may not be charged dismantled thrown into fire or short circuited 4 Protect battery from excess heat Take the battery out of the product if they are spent or in case you no longer use the article This prevents damage caused by leaking battery 5 Always replace the ...

Страница 21: ...kets located on top of the device 3 Holding the insulated portion of the connector push the plug end of the wire into one of the jacks see drawing one or two sets of wires may be used 4 This device has two output receptacles controlled by Channel 1 and Channel 2 at the top of the unit You may choose to use one channel with one pair of lead wires or both channels with two pairs of lead wires Using ...

Страница 22: ...he exact site indicated by your physician or therapist Be sure the skin surface over which electrodes are placed is thoroughly cleaned and dried Make sure the electrodes are placed firmly to the skin and make good contact between the skin and the electrodes Place the electrodes over the skin attach them properly firmly and evenly Caution 1 Before applying the self adhesive electrodes it is recomme...

Страница 23: ...out alternative stimulation settings and or electrode placements Once an acceptable location has been achieved mark down the electrode sites and the device settings so the patient can easily continue treatment 4 5 Turn on Before using the device for the first time you are strongly advised to take careful note of the contraindications and safety measures detailed at the beginning of this manual Saf...

Страница 24: ... program B outside of the box will be flashing 2 Set Cycle Time Optional Cycle time is adjustable from 5 to 30 seconds Only modulation has this parameter setting Press S button cycle to enter this menu and then press the and button to adjusting the setting 3 Set Timer Press S button cycle to enter this setting The treatment time is adjustable from 1 to 60 minutes or Continuous Press or button cont...

Страница 25: ... from 1 to 60 minutes or Continuous Press or control to adjust setting You can set the timer to Continuous mode by pressing the button when it shows 60 minutes The output will be shut off when time is up 3 Set Pulse Width The pulse width determines the length of time Each electrical signal is applied through the skin which controls the strength and sensation of the stimulation Press S button cycle...

Страница 26: ...time 4 8 Adjust Channel Intensity Press the intensity control button and to control the intensity output Slowly press the intensity button control until you reach the setting recommended by your physician or therapist Repeat for the other channel if both channels are to be used Caution 1 If the stimulation levels are uncomfortable or become uncomfortable reduce the stimulation intensity to a comfo...

Страница 27: ...the button is locked you can press only one of the buttons to unlock and then press the M button or the button to control stop the treatment 4 11 Turn OFF PRESS button and HOLD for approximately 3 seconds to turn OFF the device Caution 1 If there is no operation in the panel for 2 minutes in the waiting state the device will be turned off automatically 2 In shutdown state keep pressing the channel...

Страница 28: ... intensity level 5 Program Mode Program Modulation Method Frequency Pulse Width Treatment time TENS B Burst 0 5 5Hz 50 300us 1 60min continuous N Continuous 1 150Hz 50 300us 1 60min continuous M Pulse width modulation 1 150Hz 50 300us 1 60min continuous M1 Frequency modulation 1 150Hz 50 300us 1 60min continuous EMS S Synchronous mode 1 150Hz 50 300us 1 60min continuous A Asynchronous mode 1 150Hz...

Страница 29: ... from adhesive patches that are excessively stretched across the skin during application To prevent this apply electrodes from center outward avoid stretching over the skin 5 To minimize pulling stress tape extra lengths of lead wires to the skin in a loop to prevent tugging on electrodes 6 When removing electrodes always remove by pulling in the direction of hair growth 6 2 Cleaning the device 1 ...

Страница 30: ... It is recommended that at minimum 1 5 x 1 5 self adhering electrodes should be used at the treatment area 3 Inspect your electrodes before every use Replace electrodes as needed Reusable electrodes may cause slight skin irritation lose adhesion and deliver less stimulation if overused To use these electrodes To remove your electrodes ...

Страница 31: ...nd consult your clinician Read the instructions for use of self adhesive electrodes before application Always use the electrodes with the requirements of the IEC EN60601 1 ISO10993 1 5 10 and IEC EN60601 1 2 such as with CE mark or are legally marketed in the US under 510 K procedure 6 4 Cleaning the Electrode s cords Clean the electrode cords by wiping them with a damp cloth Coating them lightly ...

Страница 32: ...rodes or lead wires Replace and re connect Replace Stimulation is uncomfortable Intermittent output Lead wires Program option in use 1 Verify connection is secure and firmly seated 2 Turn down the intensity Rotate lead wires in socket 90 If still intermittent replace lead wire 3 If still intermittent after replacing lead wire a component may have failed Call the repair department Some programs wil...

Страница 33: ...p 1 The device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR11 Class B The device is suitable for use in all establishments other than domestic and those directly connected to the public low voltage power supply network that supplies buildings used for domestic pur...

Страница 34: ...which bserved to v nce is observ ting the dev MHz field s on Electrom environmen vironment ctromagnetic rtable and m uipment sho rt of the devi ommended m the equat he transmitt commended 80M 800 ere P is the he transmit Transmitt ommended ld strength determined rvey should mpliance lev quency rang erference m uipment mar mbol cy range ap ons Electrom objects and e stations fo AM and FM r curacy T...

Страница 35: ... device waste after thei nd take this de which is resp ectrical Protec separation d mmunication omagnetic e r or the user ng a minimu ers and the tions equipm eparation dis 80 80 MH ut power not e estimated e maximum anufacturer aration dista ot apply in al objects and 1 ting instruction n the product es are recycla ir useful life H evice to the ap onsible for wa ction BF distances be ns equipmen ...

Страница 36: ... not extend the warranty period either for the device or for the replacement parts 3 The following is excluded under the warranty All damage which has arisen due to improper treatment e g nonobservance of the user instruction All damage which is due to repairs or tampering by the customer or unauthorized third parities Damage which has arisen during transport from the manufacturer to the consumer ...

Страница 37: ...T E N S P r o s ...

Страница 38: ...T E N S P r o s ...

Страница 39: ...T E N S P r o s ...

Страница 40: ...ENSPros Manufactured for Current Solutions TM LLC 3814 Woodbury Drive Austin TX 78704 Ph 800 871 7858 www currentsolutionsnow com ...