background image

Leonardo

HOOD

Pre-installation and installation manual

LN2T
LN3T
LN650

Содержание Leonardo LN2T

Страница 1: ...Leonardo HOOD Pre installation and installation manual LN2T LN3T LN650...

Страница 2: ...anufacturer can solve any technical problem regarding installation Do not hesitate to contact him in case of doubt Introduction 1 CHECKS BEFORE PURCHASING 3 2 OVEN ELECTRICAL DATA Leonardo 2T oven tec...

Страница 3: ...installation room is dedicated and suitable to cooking food has adequate air ventilation complies with the current regulations on health and safety and systems in the workplace is protected from the...

Страница 4: ...he equipment have a 150 mm 5 91 in diameter to guarantee correct draught up to a maximum of 20 linear metres 787 4 in three curves and a terminal on the roof meet current regulations The recommended m...

Страница 5: ...1 2 0 0 qv m3 h qv m3 h P W psf Pa psf mmcda 2 Technical data Fan technical data Characteristic curves acoustic features qv flow in m3 h psf Static pressure in mmcda and Pa P Incoming power in W SFP S...

Страница 6: ...1in 85mm 3 37in 570 50mm 22 46in 737 50mm 29 04in D E 820mm 32 28in 820mm 32 28in Cooking chamber DIMENSIONS without steamer with steamer 2 Oven electrical data Leonardo 2T oven technical data model r...

Страница 7: ...in 245mm 9 63in A B C D E I G a b e f b g c d a b c h 18 h 25 400mm 15 77 470mm 18 52 174mm 6 86 244mm 9 61 279mm 10 98 349mm 13 74 280mm 11 02 350mm 13 78 d 1369mm 53 89 1439mm 56 66 92 3 62 162mm 6...

Страница 8: ...7in 1308mm 51 50in 1162mm 45 75in 913mm 35 94in 1059mm 41 69in 173mm 6 81in 173mm 6 81in A A mm inch 450 17 72 530 20 87 610 24 690 770 850 930 1010 1090 1170 27 17 30 32 33 47 36 62 39 77 43 46 Leona...

Страница 9: ...42in 475mm 18 70in 220mm 8 66in 170mm 6 69in 731mm 28 78in 583mm 22 95in 171mm 6 73in 219mm 8 62in 460 50mm 18 13in 853 50mm 33 60in D Leonardo 2T hood technical data A Supply input B Oven smoke exha...

Страница 10: ...mm 5 00in 294mm 11 57in 1718mm 67 64in 10mm 0 39in 1728mm 68 03in F 1230mm 48 58in 820mm 32 31in Leonardo 3T oven technical data Cooking chamber DIMENSIONS without steamer with steamer model refractor...

Страница 11: ...in 450mm 17 70in A B C D G I E a b c d e f g b h 18 h 25 400mm 15 77 470mm 18 52 174mm 6 86 244mm 9 61 279mm 10 98 349mm 13 74 280mm 11 02 350mm 13 78 1369mm 53 89 1439mm 56 66 92 3 62 162mm 6 38 1515...

Страница 12: ...07in 1718mm 67 64in 1059mm 41 69in 173mm 6 81in 173mm 6 81in 1572mm 61 89in 913mm 35 94in A mm inch 450 17 72 530 20 87 610 24 690 770 850 930 1010 1090 1170 27 17 30 32 33 47 36 62 39 77 43 46 A Leon...

Страница 13: ...m 11 42in 475mm 18 70in 937mm 36 89in 786mm 30 94in 612 50mm 24 11in 1111 50mm 43 76in 171mm 6 73in 219mm 8 62in 220mm 8 66in 170mm 6 69in Leonardo 3T hood technical data A Supply input B Oven smoke e...

Страница 14: ...00in 294mm 11 57in 2084mm 82 05in 10mm 0 39in 2094mm 82 44in 1469mm 57 83in 1516mm 59 69in 1621mm 63 83in F 1600mm 63 78in 1150mm 44 99in 3 37in 3 37in Leonardo 650 oven technical data without steame...

Страница 15: ...6in 58 50mm 2 30in 30mm 1 18in 193 5mm 7 61in 1469mm 57 83in 174mm 6 86in 1836 50mm 72 30in 157mm 6 19in 151mm 5 96in 92mm 3 62in 799 5mm 31 48in 651 5mm 25 65in 633mm 24 91in A B C E G I D E Leonardo...

Страница 16: ...24in 2084mm 82 05in 1234mm 48 58in 1380mm 54 33in 173mm 6 81in 173mm 6 81in 1034mm 40 71in A mm inch 450 17 72 530 20 87 610 24 690 770 850 930 1010 1090 1170 27 17 30 32 33 47 36 62 39 77 43 46 A Le...

Страница 17: ...mm 11 42in 475mm 18 70in 220mm 8 66in 170mm 6 69in 219mm 8 62in 171mm 6 73in 1045mm 41 14in 1045mm 41 14in 731mm 28 78in 795mm 31 30in 564mm 22 20in Leonardo 650 hood technical data A Supply input B O...

Страница 18: ...ical information that is vital in case of a request for maintenance or repair of the appliance please do not remove damage or modify it Failure to follow these regulations may cause damage or even fat...

Страница 19: ...remove it with soapy water but without any corrosive or abrasive products or sharp or pointed instruments Check that all the parts making up the hood are in good condition and without any faults or br...

Страница 20: ...reading the safety warnings at the beginning of the manual Fig 6 Before connecting the hood verify that the systems the oven is connected to comply with the current regulations in the country of use D...

Страница 21: ...ok the cap off previously T Block the cable with the locknut D Plug the hood connector K into the socket P in the oven electrical panel If required the cable can be replaced by the Dealer or its techn...

Страница 22: ...L TR N L Abbreviation Description M Hood motor C Motor start capacitor CTRL Speed variation board L LEDs TR LED transformer Installed cable type H07RN F three pole cable for single phase cabling Insta...

Страница 23: ...ust system can be installed in neutral versions Fig 10 The pipe A and connection B both supplied by the manu facturer must be installed during installation Fig 11 It is then necessary to install a flu...

Страница 24: ...ff explaining to the user how to use the appliance in an optimal and safe way and how to carry out ordinary mainte nance and cleaning Positioning checks Reference chapter on page has the protective fi...

Страница 25: ...Ed 0121 70702751 REV04 Leonardo hood Installation 25 Notes...

Страница 26: ......

Страница 27: ...deemed suitable without prior notice Partial reproduction prohibited without the consent of the Manufacturer The measurements provided are indicative and not binding The original language used to prep...

Страница 28: ...CUPPONE 1963 Cuppone F lli S r l Via Sile 36 31057 Silea TV ITALY T 39 0422 361143 F 39 0422 360993 info cuppone com www cuppone com...

Отзывы: