4
SENZA VAPORIERA
Modello
LN
Alimentazione
elettrica
(V)
Potenza
(kW)
Consumo
medio
(kWh)
Assorb.
(A)
Cavo di
allacciamento
(Nxmm
2
)
Protezione
quadro
cliente
(nxA)
2T h.18
3Nx400V
11,8
7,1
17,0
5x2,5
4x20
3x280V
32,8
4xAWG7
3x40
2T h.25
3Nx400V
7
4,2
10,1
5x1,5
4x16
3x280V
19,4
4xAWG11
3x25
3T h.18
3Nx400V
16,2
9,7
23,4
5x4
4x32
3x280V
45,0
4xAWG7
3x50
3T h.25
3Nx400V
9,6
5,8
13,9
5x2,5
4x20
3x280V
26,6
4xAWG9
3x32
650
3Nx400V
18
10,8
26,0
5x4
4x32
3x280V
50,0
4xAWG7
3x63
CON VAPORIERA
Modello
LN
Alimentazione
elettrica
(V)
Potenza
(kW)
Consumo
medio
(kWh)
Assorb.
(A)
Cavo di
allacciamento
(Nxmm
2
)
Protezione
quadro
cliente
(nxA)
2T h.18
3Nx400V
13,3
8,0
19,2
5x2,5
4x20
3x280V
13,0
7,8
36,2
4xAWG7
3x40
2T h.25
3Nx400V
8,5
5,1
12,3
5x1,5
4x16
3x280V
8,2
4,9
22,8
4xAWG11
3x25
3T h.18
3Nx400V
17,7
10,6
25,5
5x4
4x32
3x280V
17,4
10,5
48,4
4xAWG7
3x50
3T h.25
3Nx400V
11,1
6,7
16,0
5x2,5
4x20
3x280V
10,8
6,5
30,1
4xAWG9
3x32
650
3Nx400V
19,5
11,7
28,1
5x4
4x32
3x280V
19,2
11,5
53,4
4xAWG7
3x63
C Electrical connection (qualified electrician’s inspection)
√
For a correct connection during the installation:
•
provide sockets
connecting to the electrical network near the oven. If the oven has a double chamber,
there must be two connecting sockets
.
•
use a cable and a plug:
appliances are supplied without either power cable or plug: they must both be fitted by qualified personnel. The cable must be only
of the type stated
and the
plug fitted to it must be suitable for the consumption and connection of the oven to the electrical mains.
•
check that the systems in the room comply with the legal provisions in force in the country of use
and meet the specifications on the serial number plate. For a correct electrical
connection, the appliance must:
• be included in an
equipotential system
in compliance with the legislation in force. This connection must be made between the various devices with the terminal marked with the
equipotential symbol
. The cable must have a maximum cross-section of 10 mm2(in compliance with IEC EN 60335-2-42:2003-09) and must be yellow-green;
• must be
grounded
to the mains (green-yellow wire);
• must be connected to a
thermal differential switch
in compliance with the regulations in force (0.03A A type);
• must be connected to an
omnipolar circuit breaker
allowing complete disconnection in overvoltage III category conditions.
Preparations