If UPS does not work in case of power failure

 

UPS l's batteries may be faulty, the cradle may be defective. Talk to your 
dealer. 
UPS control distance is short.  The battery of your controller may be exhausted, 
dense electrical cables are passing through the regions close to the antenna of 
the UPS, there may be intensity (interference) in the 433 MHz band. Talk to 
your dealer. If the shutter works in one direction Motor output ends may be 
connected incorrectly. 
Straighten the cables The UPS may have malfunctioned due to a bad 
connection. Talk to your dealer. 
If the shutter does not work in case of power failure 
Shutters may be stuck; batteries may be empty. Talk to your dealer. 
If the led is not light UPS may not be receiving electricity. The fuse may have 
blown. 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAILURE CASES 

Technical Specification 

Model 

: 1100 

Power 

: 1000 W 

Input Voltage 

: 220 VAC, 1 phase 

Input Frequency 

: 50/60 Hz 

 

 

Output Voltage 

: 220 VAC, 1 phase 

Output Frequency 
Grid Operation Range 
RF Operation Frequency 
Battery Type 
Battery No & Warranty 
Charge Period 
Standby Period 
Remote Controller Range 
 Alarms & Warnings Indicators 
Protection 
Operation Temperature 
Net & Lifting Weight 
Dimensions 
Options 

: 50/60 Hz 
: 170-230 VAC 
: 433,92 MHz 
: Maintenance free dry type 
: 2 pcs 12 V 7 Ah / 2 Year 
: 12 hours 
: 4 Days (100 Hours) 
: 30 Meter 
: warning on operation from the battery, no network warning  
: Grid Voltage (Line) and Inverter (Battery) warning led 
: Excessive load protection, short circuit protection 

0°C 

50°C

 

: 6.4 kg / 160- 220 kg 
: 370 x 320 x 150 mm 
: External receiver, 42 pieces remote controller 