Cuppon CSD 150 Скачать руководство пользователя страница 13

24

25

• The manufacturer reserves the right to make any changes which deemed beneficial 

or necessary.
• Electrical safety of your product can only be ensured if only it is connected to an 

earthing system accurately. The manufacturer cannot be held responsible if these 

conditions are not complied with.
• Assembly of electronic parts should be performed only by authorized personnel. 

Any maintenance or service should be performed by an expert authorized by the 

manufacturer.
• The product you purchased can be used as a general entrance and exit. It cannot 

be used as an emergency exit.
• Do not put any foreign object into the rail region or door mechanisms.
• Please don’t prevent opening or closing of moving door or any equipment by any 

object, equipment, or machinery.
• Do not force the door for opening or closing for any reason.
• Do not put inflammable or burning objects next to the door.
• Do not reset functions of faulty door without assistance of an expert authorized 

by the manufacturer company, or without reading assembly and installation 

instructions.
• Please do not perform works which should normally be performed by the expert 

authorized by the manufacturer.
• Please do not put moving tools or materials within radar detection distance of the 

door. It is recommended to use micro-radar with curtain photocell for a full safety.
• While the door is in automatic state, do not clean, and make sure that electronic 

parts don’t have contact with water.
• During maintenance of door, please make sure that the system is closed.
• Please do not exert excessive power to the doors or accessories under any 

condition.
• Please keep DVDs for future reference which include assembly and user’s manual, 

and assembly video of the product.
• Please cut off the power prior to perform any work on the system.
• Check if the earthing is done properly. All metal components of closing sections 

(building doors, garden gates, etc.) and all components of the system which have 

earthing end to the earthing line.

SAFETY WARNINGS

Operating Voltage

230 V AC±10% 50 Hz

Motor Voltage

24 V DC

Opening Speed (Adjustable)

0.9m/s

Closing Speed (Adjustable)

0.7m/s

Max. Leaf Weight

75kg (1 leaf), 75+75kg (2 leaves)

Kit Measurements & Weight

50x30x15cm/11kg

Fault Notification

With a led indicator on the main board

Motor Lock

Available

Self Positioning

Available

Extra Photocell

Optional

Manual Sensor

Optional

Numbering Machine & RF Card Reader

Optional

Always Closed-Open

Available

Automatic Operation

Available

Current Taken

0.6A

Motor Power

95W

Opening Time

3 & 5 seconds (2 levels with a switch)

Protection Degree

IP 20 (Only for dry environments)

Operating Temperatures

from -15°C to 60°C

Aluminum Frame Measurements

3.5 / 4.5 / 6.5 meters

Adjustable Open Time

2 levels with a switch

Adjustable Speed

Available

Photocell

Available

Height Photocell

Optional

Curtain Photocell Microwave Radar

Optional

Bluetooth Technology

Optional

Elbow Button

Optional

ID Car Pass

Optional

Only Entrance-Exit

Available

Half-Opening

Manually adjustable

TECHNICAL SPECIFICATIONS
Technical Specifications

CSD 150

AUTOMATIC SLIDING

Содержание CSD 150

Страница 1: ...CSD 150 AUTOMATIC SLIDING USER S MANUAL ...

Страница 2: ...s The assembly should be performed only by qualified staff Please cut off the power prior to perform any work on the system Please pay special attention to warning symbols or notes which can be seen within the guide These symbols and notes are the warnings intended for preventing damage to the operators and safety of other people The manufacturer may not be held responsible for the workman ship or...

Страница 3: ...ION 01 Microprocessor Control Unit 02 Radar Movement Sensor 2 03 Safety Photocell Receiver Transmitter 04 Position Switch 05 Motor with Encoder 06 Curtain Radar Option 01 02 03 04 05 06 07 08 09 10 11 12 SOCKET CONNECTIONS WARNING Materials used during assembly should be in accordance with applicable standards and connections should be performed by an authorized personnel PHOTOCELL TRANSMITTER CLO...

Страница 4: ...L RADAR POSITION SWITCH TRANSMITTER PHOTOCELL PHOTOCELL RECEIVER TRANSMITTER RECEIVER PHOTOCELL EXTERNAL RADAR CLOSING SPEED 5A FUSE CHECK SWITCH NEUTRAL FAZ ON OFF SWITCH OPENING SPEED OPEN CLOSE CHECK CLOSE OPEN CSD 150 AUTOMATIC SLIDING ...

Страница 5: ... obstacle found between doors through infrared signals for safety and control In order to ensure an optimum operating efficiency the Receiver and the transmitter should be level The highest distance between the photocell transmitter white and photocell receiver red should be 5 meters at maximum Sensors should be vertical and on the same line When transmitter and receiver sensors of the photocell d...

Страница 6: ...ternal Radar Black Minus Green COM COMMON PHOTOCELL TRANSMITTER RECEIVER CLOSE OPEN EXTERNAL RADAR EXTERNAL RADAR White Green Red Black Black Red Green White External Radar Cable Quad cable with 1 5 m length black socket External Radar Black Minus Green COM COMMON Red Plus White INP INPUT PHOTOCELL TRANSMITTER CLOSE OPEN OPERATING FUNCTIONS RADAR 2 External Radar This is the radar for detecting mo...

Страница 7: ...pen Close Door opening or door closing movements can be performed by Open Close Inputs with normally open button no contact When Open input is triggered the door moves to the opening direction when the waiting time elapsed the door closes to the closing direction When Close1 input is triggered if the door is open then the door closes without any waiting time NORMALLY OPEN BUTTON PHOTOCELL TRANSMIT...

Страница 8: ...D 150 card when it is first energized LD9 led flashes If the led flashes this means that the card isn t installed In order to start installation please hold down RESET button for 3sec LD9 will illuminate continuously during installation When the installation is successfully completed the led goes off RESETTING When there is no energy the system will reset if RESET button is kept pressed and the sy...

Страница 9: ... RF Card Reader Reset Switch Screw Fastening Hole Cable Diagram Port Screw Red Black SELS Manual Sensor RED BLACK YELLOW WHITE GREEN BLUE PURPLE ORANGE BROWN GRAY Blue Violet Door Bell Unlock Exit Button GND PUSH OPEN OPEN COM COMMON NO DOOR RING SELS Manual Sensor Orange Yellow Relay N C Contact Relay N O Contact Minus Voltage Input Plus Blue Red SDA Touch Screen Switch Dry Contact Normally Open ...

Страница 10: ... Position Switch Cable Triple with 2 5m length WHITE I AUTOMATIC MODE RED 0 ALWAYS CLOSE BLACK II ALWAYS OPEN OPERATING FUNCTIONS DOOR CONTROL WITH RF In order to control the door with remote control Indefinite SN 12 plus receiver is connected to the Position Switch There are available two methods A Opening the door with remote control and after a certain time automatically closing the door Com an...

Страница 11: ...weights of leaves considering the doors which exceed 100kg please assemble 2 wheeled carrier for each leaf the wall or structure where the product is mounted conformable with regulations the wall which supports the product is flat smooth and vertical to the ground 13 3 7 6 4 2 1 Microprocessor Control Unit 2 Safety Photocell Receiver Transmitter 3 Motor with Encoder 4 Radar Movement Sensor 5 Posit...

Страница 12: ...onnection is ensured Microprocessor unit is operating but the door doesn t move Keeping the door continuously opened or closed on the position switch Please make sure that operating mode on the position switch is selected as Input output active Safety photocell doesn t work Safety photocells cannot detect each other as a result of vertical position of receiver and transmit ter and that they are no...

Страница 13: ...contact with water During maintenance of door please make sure that the system is closed Please do not exert excessive power to the doors or accessories under any condition Please keep DVDs for future reference which include assembly and user s manual and assembly video of the product Please cut off the power prior to perform any work on the system Check if the earthing is done properly All metal ...

Страница 14: ...26 27 NOTLAR NOTLAR ...

Страница 15: ...28 ...