Cumberland PNEG-1640 Скачать руководство пользователя страница 6

6

PNEG-1640

 Smart IR Sensor

2. Application

The Smart IR Sensor is used as the primary control for a Flex-Flo feed line. It uses “infrared” technology 
to detect the presence of all types of mash and pellet feeds. It is designed to be used in place of a proximity 
switch or drop tube switch and will operate with or without the aid of a power relay. The sensor is installed 
underneath a control unit between the powerhead drop (funnel) and the drop tube at the end of a Flex-Flo 
feed system.

Figure 2A 

Содержание PNEG-1640

Страница 1: ...PNEG 1640 Smart IR Sensor Installation and Operation Manual PNEG 1640 Date 12 21 11...

Страница 2: ...2 PNEG 1640 Smart IR Sensor...

Страница 3: ...e Operation 10 Delay Time By Pass 10 Chapter 6 Run Time 11 Maximum Run Time 11 Check Maximum Run Time Setting 12 Setting Adjusting the Maximum Run Time 12 Maximum Run Time Operation 13 Resetting the M...

Страница 4: ...lure to read this manual and its safety instructions is a misuse of the equipment and may lead to serious injury or death DANGER WARNING CAUTION NOTICE This is the safety alert symbol It is used to al...

Страница 5: ...near your telephone Keep Emergency Equipment Quickly Accessible Wear Protective Clothing Wear close fitting clothing and safety equipment appropriate to the job Remove all jewelry Tie long hair up an...

Страница 6: ...to detect the presence of all types of mash and pellet feeds It is designed to be used in place of a proximity switch or drop tube switch and will operate with or without the aid of a power relay The...

Страница 7: ...e drop tube at the end of a Flex Flo feed system The control unit power head drop funnel must be an FLX 2017 or equivalent with an outlet measuring approximately 3 1 4 O D Use two 2 10 x 3 4 self dril...

Страница 8: ...Full When the feed falls away from the sensor it will count down a pre determined delay time and then turn the Flex Flo system back on It also includes a maximum run timer that will shut the system do...

Страница 9: ...ull Large capacity feeders or younger smaller animals will allow for longer delay time settings For best results use a slightly less delay time setting than the time it takes the animals to completely...

Страница 10: ...the yellow Product Detected indicator light goes off the delay time will begin to count down from its maximum setting During this time the green Auger indicator light will flash After the delay time...

Страница 11: ...o system off in case of an empty or bridged feed tank or a feed spill In the case of an empty or bridged feed tank it will prevent the Flex Flo system from running empty for extended periods of time I...

Страница 12: ...Setting Setting Adjusting the Maximum Run Time To adjust the maximum run time setting at any time while pushing and holding the Maximum Run Time button push either the arrow up or arrow down button E...

Страница 13: ...the display showing the maximum run time setting will begin to flash alternately with the red Alarm indicator light The alarm contacts inside the Smart IR Sensor will now change state If these contact...

Страница 14: ...this sensor is not affected by temperature humidity or type of feed If the sensor fails to operate properly disconnect the sensor from the powerhead drop above and use a soft cloth to clean the dust...

Страница 15: ...PNEG 1640 Smart IR Sensor 15 NOTES...

Страница 16: ...16 PNEG 1640 Smart IR Sensor 8 Replacement Parts Smart IR Sensor Assembly FLX 4951...

Страница 17: ...Part Description Qty 1 FLX 5000 Infrared Sensor Housing Assembly 1 2 FLX 5002 Infrared Sensor Insert Assembly 1 3 FLX 5003 Infrared Sensor Power Board Assembly 1 4 FLX 5001 Infrared Sensor Connector...

Страница 18: ...18 PNEG 1640 Smart IR Sensor 9 Wiring Diagrams Alarm Wiring Diagram...

Страница 19: ...9 Wiring Diagrams PNEG 1640 Smart IR Sensor 19 AP Wiring Diagram...

Страница 20: ...9 Wiring Diagrams 20 PNEG 1640 Smart IR Sensor AP Wiring Diagram Continued...

Страница 21: ...9 Wiring Diagrams PNEG 1640 Smart IR Sensor 21 Choretime Wiring Diagram...

Страница 22: ...9 Wiring Diagrams 22 PNEG 1640 Smart IR Sensor Universal Wiring Diagram...

Страница 23: ...E OR DESIGN OF SUCH PRODUCTS GSI shall not be liable for any direct indirect incidental or consequential damages including without limitation loss of anticipated profits or benefits The sole and exclu...

Страница 24: ...on codes and applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made 1004 E Illinois St Assumption IL 6...

Отзывы: