background image

PNEG-1433

54" Galvanized Slantwall Fan

Model:

G54SCL16GA

Installation and Operation Manual

PNEG-1433

Date: 01-01-15

Содержание G54SCL16GA

Страница 1: ...PNEG 1433 54 Galvanized Slantwall Fan Model G54SCL16GA Installation and Operation Manual PNEG 1433 Date 01 01 15...

Страница 2: ...operation of the fan FEATURES One year warranty on parts Consistent airflow through flock grow out Easy assembly and maintenance On site service and support Unpacking Before beginning installation ch...

Страница 3: ...tions 9 Chapter 3 Installation Specifications 10 Chapter 4 Cone Panel Assembly 11 Chapter 5 Shutter Installation 12 Chapter 6 Electrical Wiring 13 Electrical Hook Up 13 Chapter 7 Operation and Mainten...

Страница 4: ...nual and its safety instructions is a misuse of the equipment and may lead to serious injury or death DANGER WARNING CAUTION CAUTION This is the safety alert symbol It is used to alert you to potentia...

Страница 5: ...codes and applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made Install and Operate Electrical Equip...

Страница 6: ...job Remove all jewelry Tie long hair up and back Wear safety glasses at all times to protect eyes from debris Wear gloves to protect your hands from sharp edges on plastic or steel parts Wear steel to...

Страница 7: ...igned for use in atmospheres where there is a risk of explosion Such environments may include but are not limited to enclosed areas of high dust concentrations gas vapors and fumes Use in such an envi...

Страница 8: ...ircuit breaker or slow blow motor type fuse must be used A safety cut off switch should be located adjacent to each fan Contact your local distributor for the correct cut off switch The motor must be...

Страница 9: ...orner outside WARNING SHEAR POINT Keep hands clear of moving parts Do not operate with guard removed Disconnect and lockout power before servicing DC 995 GSI Group Inc 217 226 4421 Lockout power befor...

Страница 10: ...eople lift fan housing into the opening Fasten flanges to framework with the wood mounting screws provided Check the fan for vertical position before screwing flanges down The fan housing should be fl...

Страница 11: ...tall bolts along this flange as the previous other three 3 again leaving the top bolt and nut loose Install the cone panel brackets as shown in Figure 4B leaving the bolts and nuts finger tight Using...

Страница 12: ...spaced evenly Refer to Figure 5A with three 3 per side with 3 16 spacer washer in between housing and the turn button A If you do not wish to use the turn buttons A you may secure the shutter B to the...

Страница 13: ...is not the case switch the Red and Black wires Refer to the wiring diagram on the side of the motor for correct wiring for 115V and 230V supply Fans used to ventilate livestock buildings where contin...

Страница 14: ...leys and the bearings after every two 2 months of service The belt tensioner should be positioned between the 2nd and the 3rd notch as indicated by the mark on the body of the tensioner Under tensioni...

Страница 15: ...place clean as necessary Inlet outlet guards clogged by dirt debris Repair replace clean as necessary Voltage supplied is not correct must be within 10 of the nominal voltage Check line voltage at mot...

Страница 16: ...unt Bracket 1 7 017 1422 9 Sheave AK30 5 8 1 8 15 0131 Motor 1 1 2 HP 1 PH 60 Hz 1 5 SF 1 9 12 0211 Tensioner Bracket 1 10 91 0057 Rotary Tensioner with Splash Guard 1 11 16 0007 Pulley AL104 1 12 16...

Страница 17: ...Vertical Brace 2 12 0211 Tensioner Bracket 1 12 0212 Bearing Bracket 1 12 0213 Motor Mount Bracket 1 12 0214 54 Venturi 1 12 0215 Cone Panel 4 12 0217 Shaft 1 Diameter 1 12 0218 Propeller 1 15 0131 M...

Страница 18: ...18 PNEG 1433 54 Galvanized Slantwall Fan NOTES...

Страница 19: ...TS GSI shall not be liable for any direct indirect incidental or consequential damages including without limitation loss of anticipated profits or benefits The sole and exclusive remedy is set forth i...

Страница 20: ...des and applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made 1004 E Illinois St Assumption IL 62510...