Cumberland G50CBF16GA Скачать руководство пользователя страница 7

1. Safety

PNEG-1425

 50" Galvanized Butterfly Fan

7

General Safety Information

Users Manual

This manual contains information and instructions essential to the safe installation and use of the 

50" Galvanized Butterfly Fan

. This manual should be read thoroughly before attempting any installation 

or use of the fan. Keep this manual in a location that it can be readily accessed. Failure to read the manual 
and its safety instructions constitutes misuse of the product.

Safety in Handling the Butterfly Fan

This unit should be installed and maintained by a qualified technician familiar with the use and 
function of ventilation fans. This will prevent situations leading to damaged components and/or injury. 
Whenever possible, use mechanical lifting equipment when lifting or moving the fan during installation. 
Where manual handling is required, seek assistance from other people.

Correct Use of the Butterfly Fan

The fan is designed solely for the purpose of ventilating agricultural buildings. Use of the fan in any other 
way is a misuse of the equipment and may endanger yours or another person’s safety and health.

In the installation and use of the Butterfly Fan only genuine Cumberland parts are to be used. Use of 
other non-genuine parts is a misuse and may lead to dangerous situations.

This fan is not designed for use in atmospheres where the risk of explosion is foreseen. Such 
environments may include enclosed areas of high dust concentrations, gas, vapors and fumes. 
Use in such an environment is prohibited. If in doubt, contact Cumberland or your dealer.

Safety Guards

The Butterfly Fan contains moving and electrical parts which will cause serious injury, even death if 
touched. Guards are placed on the fan to protect you. Operating the fan at any time with guards removed 
or incorrectly fitted is a serious misuse of the fan and endangers you and others safety.

Safety in Maintenance

While the Butterfly Fan is designed to keep maintenance to a minimum, some items such as greasing the 
bearings and belt replacement will be required over the life of the fan. Do not attempt any maintenance 
or repairs on the fan unless you are competent to do so. Remember that the fan may, in certain situations, 
operate under automatic control and will start without warning. Never attempt any work on the fan without 
first isolating it from the power supply and locking out the isolator so that only you can turn the power back 
ON. For your safety, follow the guidelines given in the

 Maintenance Section on Page 18

 of this manual.

Before re-starting the fan, ensure that all electrical enclosures are locked, closed and all guards and 
other safety measures are correctly fitted. If in doubt, contact your dealer or Cumberland for assistance.

Содержание G50CBF16GA

Страница 1: ...PNEG 1425 50 Butterfly Fan Model G50CBF16GA Installation and Operation Manual PNEG 1425 Date 10 28 09...

Страница 2: ...FEATURES 23500 CFM 24 0 CFM W 0 05 S P One year warranty on parts Shutterless operation No shutters to clean Consistent airflow through flock growout Easy assembly and maintenance On site service and...

Страница 3: ...ation 10 Framing and Positioning 10 Installation of the Fan on a Vertical Plane 11 Tabbed Cone Panel Assembly 12 Butterfly Assembly 14 Grill Guard Assembly 15 Inlet Grill Assembly 15 Chapter 4 Wiring...

Страница 4: ...misuse of the equipment and may lead to serious injury or death This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this s...

Страница 5: ...d applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made Install and Operate Electrical Equipment Prop...

Страница 6: ...e all jewelry Long hair should be tied up and back Safety glasses should be worn at all times to protect eyes from debris Wear gloves to protect your hands from sharp edges on plastic or steel parts W...

Страница 7: ...to dangerous situations This fan is not designed for use in atmospheres where the risk of explosion is foreseen Such environments may include enclosed areas of high dust concentrations gas vapors and...

Страница 8: ...ere should also be an alarm system on at least one cooling stage For connection requirements refer to the diagram on the motor nameplate and also to information enclosed with the fan control used For...

Страница 9: ...ROTATING BLADE May cause serious injury Blade may start automatically Disconnect and lockout power sources before servicing FLYING OBJECTS HAZARD Danger of eye injury Wear eye protection DC 1540 WARN...

Страница 10: ...ssembly Ensure the load bearing portion of the bottom sill is rigid and properly supported IMPORTANT When installing more than one fan maintain a minimum of 10 between rough openings to ensure clearan...

Страница 11: ...vel be positioned vertical on the housing and shims furring strips can be used be placed behind either the top or bottom mounting flanges until the fan is fully vertical See Figure 3C Once you confirm...

Страница 12: ...ated on the outside of the cone assembly Do not tighten nuts See Figure 3E on Page 13 4 Once four 4 cone panels are assembled stand assembly up on large radius side See Figure 3D 5 Pull both ends toge...

Страница 13: ...3 Installation PNEG 1425 50 Galvanized Butterfly Fan 13 Figure 3E Figure 3F Nuts on outside of cone assembly Cone strut angles...

Страница 14: ...ne and the top lined up with the slots farthest in on the cone This will give the butterfly frame weldment a slight tilt back 1 This aids the closing of the butterfly flaps 3 Use 1 4 x 1 1 4 bolts and...

Страница 15: ...l Assembly 1 Remove the folded Inlet grill from the packaging Unfold all four 4 sides lining them up perpendicular to each other Using the black wire ties link the sides together using two 2 ties per...

Страница 16: ...3 Installation 16 PNEG 1425 50 Galvanized Butterfly Fan Figure 3L Inlet Grill Hanging Hook Top Figure 3M Inlet Grill Hanging Hook Bottom...

Страница 17: ...rect motor rotation CCW the Red wire should be located on the L2 connection as depicted If this is not the case switch the Red and Black wires Refer to wiring diagram on the side of the motor for corr...

Страница 18: ...maintenance schedule as listed below a Check the belt pulleys and the bearings after every two 2 months of service The belt tensioner should be positioned between the 2nd and 3rd notch as indicated b...

Страница 19: ...en NOTE They can be a little different without any problems If they are significantly different contact your Cumberland distributor for more information 2 Is the noise coming from the bearings Lubrica...

Страница 20: ...1 4 20 x 1 ZN Grade 5 1 15 12 0400 50 Galvanized Butterfly Sub Assembly 1 EA 16 12 0401 GY Butterfly Frame Weldment 53 Grey 1 17 12 0317 Block Mounting Nylon 2 18 12 0319 Washer Nylon 4 19 12 0406 Bu...

Страница 21: ...Bore 1 48 16 0076 Bearing 1 Pillow Block AVS FA 2 49 16 0087 1 Shaft Dual Key Tensioner 1 50 16 0088 A 46 V Belt 48 Nominal Length 1 51 91 0057 Rotary Tensioner Assembly w Splash Guards 1 52 DC 1540 D...

Страница 22: ...22 PNEG 1425 50 Galvanized Butterfly Fan 8 Exploded Diagram 7 6 1 18 5 12 11 10 16 2 17 3 4 15 14 9 19 20 13 8...

Страница 23: ...18 91 0045 Rotary Tensioner 1 19 12 0312 50 Galvanized Butterfly Cone Bracket 4 20 12 0405 Galvanized Flap Shaft 50 Butterfly 1 Ref Part Description Qty 1 11 0333 Inlet Grill 1 2 12 0197 Bottom Panel...

Страница 24: ...24 PNEG 1425 50 Galvanized Butterfly Fan NOTES...

Страница 25: ...PURPOSE OR DESIGN OF SUCH PRODUCTS GSI shall not be liable for any direct indirect incidental or consequential damages including without limitation loss of anticipated profits or benefits The sole and...

Страница 26: ...with the current installation codes and applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made 1004 E...

Отзывы: