Programming
The timer uses four buttons:
Button
Description
Set-up / Enter Key (Status)
Advance timer through display options
Reconditioning Key (REGEN)
Initiate a reconditioning cycle
Toggle Down Key (“-”)
Decrease the setting
Toggle Up Key (“+”)
Increase the setting
Time of Day
This setting is used to program the current time of day.
When in this step the display will first show “tod” for two
seconds.
After “tod” is displayed, “12:00 PM” will display (or the
current set time if already programmed) and the minutes
will flash.
The minutes are adjusted with the “+” or “-” key until the
correct value is displayed.
Press the “Regen” key to flash the hours. Adjust with the “+”
or “-” key until the correct time is displayed.
Pressing the “Status” key will move to the next
programming step. Pressing “Regen” will move back to
the minutes adjust.
Time of Reconditioning
This setting is used to program the time at which a
reconditioning cycle is to occur in the delay mode, or in
immediate mode with time clock backup on. The display
will first show “tor” for two seconds.
After “tor” is shown the display will then show the default of
2:00 AM (or the current programmed time of reconditioning
if already set). The time can be adjusted in 30 minute
increments by pressing the “+” or “-” keys.
Pressing the “Status” key will save the setting and
move to the next programming step.
Reconditioning Cycle Interval
This setting is used to set the days between reconditioning
in time clock mode.
The display will show “REG” icon and “dAY” for two seconds and
then display the numbers to change. Adjust the value with the “+” or
“-” keys.
Pressing the “Status” key will save the setting and move to the next
programming step. The reconditioning cycle interval is 3 days for the
Iron-OX5 filter system.
9