18
Programming
Power Loss
The AccuSoft
®
circuit board is equipped with a Hi-Cap Capacitor and EEPROM memory chip.
The capacitor is capable of maintaining the time, for at least one day, in the event of a power
outage. The EEPROM ensures that the individual programming parameters of your softener are
not lost.
If the power outage lasts long enough to drain the Hi-Cap Capacitor, the control will flash “12:00
PM” when power is returned to the control. The unit will continue to keep time from the moment
power is restored, and will initiate a full regeneration at the preset regeneration time. The time of
day will need to be reset in order to return the regeneration to its preset time.
If you live in an area where power outages occur with a regular frequency, a battery backup
option is available for ensuring that the time of day is properly maintained. Contact your Culligan
Dealer for more information.
Display
Back lit LCD display.
Program Key Depress to enter and move through the programming steps.
Regeneration
Key
Press and hold the key for three (3) seconds to initiate an immediate
regeneration.
When pressed during programming the time of day, this key will allow the user
to toggle between the hours and minutes setting of timing program segments.
Information
Key
Each time depressed, the Information key will display statistical information such
a flow rate, time of day. Use with the Toggle Down key to display other statistical
information.
Toggle Down
Key
In the programming mode this key will move the user through the programming
function in a descending mode. If depressed for greater than three seconds, the
rate at which the display scrolls through data will increase.
Toggle Up
Key
In the programming mode this key will move the user through the programming
function in an ascending mode. If depressed for greater than three seconds, the
rate at which the display scrolls through the data will increase.
This key will also allow the user to manually step through the cycles of
regeneration.
Program
Regen
Information
Setting Time Of Day
1. Press Information until 'tod' is displayed.
2. Use arrow keys to adjust minutes.
3. Press Regen once then adjust hours.
4. C ontinue to press Information to exit menu & save.
Press Regen once to begin regeneration tonight,
Or hold for immediate regeneration.
Display
Program Key
Regeneration Key
Information Key
Toggle Up
Toggle Down