![Culligan HE-060 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/culligan/he-060/he-060_installation-operation-and-service-instructions_2697762010.webp)
6
Culligan® High Efficiency 1.5 Twin Water Softener
6
Cat. No. 01024821
Loading the Media
Table 3. Loading quantities.
Model
HE-060
HE-090
HE-120
HE-150
HE-210
Cullex (Ft
3
)
2
3
4
5
7
Cullsan (lbs)
30
40
40
70
80
Freeboard (inches)
24
27
30.5
30
27.5
NOTE Do NOT attempt to load the media without having the tank in its final position. Moving the tank once
the media has been loaded will be difficult at best.
Figure 2.
1. Cover the top of the distributor pipe with
tape that will prevent media from entering
the distributor.
2. Use a funnel (P/N 01029516) in the opening to
add 6” of water to protect the distributor. Pour
Cullsan per Table 3, level before adding resin
NOTE If you are planning on using an
Aqua-Sensor device for regenera-
tion initiation, install now on the lead
3. Pour bags of Cullex per Table 3.
4. Clean tank threads, remove tape and check for
any foriegn materials
NOTE Minimize the amount of water added
until final positioning of the tank
with the control valve mounted.
Freeboard
Cullex
Cullsan