27
01040707 B 07/21
Culligan Aquasential Smart HE 10" Sulfur-Cleer Water Filter
Culligan knows the more informed you are about your water treatment systems, the more confident you will be about its performance� It’s because
of this and more than seventy years of commitment to customer satisfaction that Culligan is providing this Performance Data Sheet to its customers�
NOTE!
Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs.
It is recommended that before purchasing a water treatment unit, you have your water supply tested to determine
your actual water treatment needs.
Manufacturer:
Culligan International Company
9399 W� Higgins Rd�, Suite 1100
Rosemont, IL 60018 USA
(847)
430-2800
Product: Culligan Aquasential Smart High Efficiency 10" Sulfur-Cleer Water Filter
Testing Conditions & Results:
Capacity:
1,000 gallons
Pressure:
20 - 60 psi
Service Flow Rate: 5�0 gpm @ 4�0 psi
Temperature: 33 - 120° F (1 - 49° C)
pH:
7�0 - 8�5
Operating Conditions:
Operating Temp� Range: 33 - 120° F (1 - 49° C)
Water Press� Range:
20 - 60 psi (138 - 400 kPa)
Electrical Characteristics: 24 VDC, 21�6 Watts
Water Press� Range (Canada):
20 - 60 psi (138 - 400 kPa)
Substance Reduction
This system has been tested according to NSF/ANSI standard 42 for reduction of the substances listed below� Testing was performed under
laboratory conditions, actual results may vary�
Model
Name of Substance
USEPA
SDWA
MCL
Percent
Reduction
Avg Test
Influent
Concentration
Level
Avg Test Effluent
Concentration
Level
10" Fiberglass
Hydrogen Sulfide
0�3 mg/L
98�9%
8�2 mg/L
0�091 mg/L
Iron
98�7%
10�4 mg/L
0�14 mg/L
10" Quadra-Hull
Hydrogen Sulfide
0�3 mg/L
98�9%
8�2 mg/L
0�091 mg/L
Iron
98�7%
10�4 mg/L
0�14 mg/L
The Aquasential Smart High Efficiency Sulfur-Cleer™ 10" fiberglass
and Quadra-Hull filters have been tested and certified by WQA against
NSF/ANSI Standard 372, CSA B483�1, and NSF/ANSI Standard 42 for
the effective reduction of sulfur up to 1,000 gallons for the 10" filter as
verified and substantiated by test data�
The concentration of the indicated substances in water entering the system
was reduced to a concentration less than or equal to the permissible limit
for water leaving the system as specified in NSF/ANSI 42�
Performance Indicator:
If water flow decreases or a noticeable taste change occurs a reconditioning cycle should be initiated� If conditions do
not improve, contact your local Culligan dealer� They can determine if your filter requires servicing� Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection before or after the system� Refer to the Specifications, Familiarization and Warranty
section of this Owner’s Guide (P/N 01040707) for more specific product information� To avoid contamination from improper handling and
installation, your system should only be installed and serviced by your Culligan dealer� Performance will vary based on local water conditions�
The substances reduced by this system are not necessarily in your water�
Buyer Signature _______________________________________________________________________ Date ____________________
Seller Signature _______________________________________________________________________ Date ____________________