![Cuisinart COH-100 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/cuisinart/coh-100/coh-100_manual_2697187017.webp)
7
11
Note:
Visually check the burner flame against the illustrations:
Flame should be blue with slight yellow tips.
You should see a smaller flame in LOW position than seen
on HIGH. Perform flame check prior to each use. If only low
flame is seen, refer to “Burner flame is low” in the
“TROUBLESHOOTING” on page 19.
1. Check the control knob is in the OFF.
2. Position a long lit match or lighter close to the
Pilot box.
3. Push control knob in and rotate to PUSH.
The burner should lit within 5 seconds
4. If the burner fails to stay lit or becomes
extinguished, turn the burner control knob to
OFF, wait 5 minutes for gas to clear and then
repeat step 3.
1. Check the control knob is in the OFF position.
2. Turn on the LP tank valve slowly.
3. Press and hold the IGNITOR button to create
sparks and then push control knob in and
rotate to PUSH. Once burner is lit, continue to
hold the control knob for 30 seconds. Then the
burner should stay lit.
4. If the burner fails to stay lit or becomes
extinguished in 30 seconds, turn the control
knob to OFF , wait 5 minutes for gas to clear
and then repeat step 3.
5. To desired heating level rotate knob from LOW
to HIGH.
6. To turn off, turn the knob to PUSH first, then
push in and turn to OFF. Turn off the gas tank
valve before disconnecting the LP gas tank.
NOTE:
If the burner does not ignite within the first few attempts of match/Lighter lighting, there is a
problem with the gas supply. Turn off the gas at the burner and tank. DO NOT attempt to operate the
unit until the problem is found and corrected. Please call the customer service department at
1-866-994-6390 from 9:00am to 5:00pm Eastern Time, Monday through Friday for assistance.
OFF
LOW
HIGH
PUSH
PUSH
IGNITOR
LIGHTING INSTRUCTIONS
USING A LONG MATCH/LIGHTER TO LIGHT