Touch Panel Controllers / Connecting

© CUE, a.s. All Rights Reserved.

IR/SERIAL

This type of port provides

 

Output for infra-red emitters (IR Adapter /i), maximum IR output rate is 1.2 MHz.

 

RS-232 serial output (one way), maximum serial data rate is 115 200 Bd (bps), output signal levels  

for RS-232 are in the -12 V to +12 V range.

The IR outputs and RS-232 outputs can be combined on independent outputs (for example three outputs can 

be used as IR, five outputs can be used as RS-232).
Connector pin out

IR/SERIAL 

2-pin 3.5 mm

Pin

Signal

Description

S G

S

Signal

IR/Serial Signal (Output)

G

GND

Ground

Notes

 

All pins labelled G are connected together.

 

Up to three original infra-red emitters IR Adapter /i can be connected to each output in parallel.

 

Up to ten IR Sprayers can be connected to each output in parallel

 

It is not recommended to connect more infra-red emitters of various manufacturers in parallel because 

the output can be either overloaded or damaged.

Содержание uniCUE-12-B

Страница 1: ...User Manual Touch Panel Controllers 10 12 2012...

Страница 2: ...Download User Application 26 Overview 26 Using Cue Visual Composer 27 Using Admin Web 28 IR Capture 29 Factory Default and System Default 30 On Screen Display 30 Access On Screen Display 30 Startup M...

Страница 3: ...niCUEs provide video preview right on the touch panel Streaming or downloaded video can be viewed at any location on the display or in full screen mode Integrated front panel speakers provide clear au...

Страница 4: ...erfaces can be connected using RS 485 serial ports In addition uniCUE is fully compatible with other CUEunits such as touch panels and controllers connected via Ethernet Following figure describes uni...

Страница 5: ...7 B uniCUE 12 B Touch panel controller uniCUE 7 B 1 Touch panel controller uniCUE 12 B 1 Power supply 30 W 1 1 Power cable 1 1 Ethernet cable straight through 1 1 IR Adapter i 2 2 Connector set 1 1 C...

Страница 6: ...uttons Multifunctional for power and programmed functions Reset Set factory default Memory 256 MB RAM microSD Card min 4 GB upgradable Control ports 2x Bi directional serial RS 232 422 485 2x 5 pin co...

Страница 7: ...er 485 This means that touch panel can receive IR signal from CUE wireless IR control panels without the need to use any external IR receiver Light Sensor The Light Sensor automatically adjusts displa...

Страница 8: ...irectly from touch panel Devices can be controlled directly without controller Audio Two 3 pin connectors provide unbalanced audio line input and output Power Output 5 VDC This 2 pin provides 5 VDC ou...

Страница 9: ...ERMISSION OF FAKTUM DESIGN IS PROHIBITED LAST C c b a DATE SPECIFICATION INDEX NAME John CREATED 9 5 2010 DRAW TOLERANCES ISO 2768 mK DEBUR AND BREAK SHARP EDGES 320 224 9 6 5 17 5 60 4 58 17 5 5 4 3...

Страница 10: ...for uniCUE 7 B and uniCUE 12 B build in touch touch panel controllers It is designed for pre construction applications The back box is equipped with knockouts for cable installation 134 8 189 45 8 Di...

Страница 11: ...mm 7 mm touchCUE 7 B Front Panel Outline 198 x 147 mm touchCUE 12 B Front Panel Outline 320 x 225 mm Back Box Cutout 7 mm 7 mm 2 Break suitable knockout 3 for comfortable stretch of cable 3 Make sure...

Страница 12: ...out 3 for comfortable stretch of cable 3 Insert the back box 2 into the hole 1 and take the cables through broken off knockout 4 Fix the back box 2 with mortar or plaster 5 Neaten the visible front pa...

Страница 13: ...on the other side of the back box Guide ruler EZ A A Ra 3 2 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF FAKTUM DESIGN ANY REPRODUCTION IN PART OR AS...

Страница 14: ...h holds in this position and mount cables If you want to place the panel in the back box hold it upright and push its bottom part stron gly as deep into the back box as possible Then push the upper pa...

Страница 15: ...ides of the touch panel and push until the metal catches get loose Then you can tilt the upper part of the touch panel Hold the panel upright and pull its bottom part out In this position you can tilt...

Страница 16: ...n soft texture cloths cotton 2 Spray bottle of cleaning solution without alcohol window cleaner 3 Aluminium parts should be cleaned using a special cleaning solution Steps are 1 Turn the touch panel o...

Страница 17: ...1 OUT IN AUDIO LINE R G L L G R GENERAL I O S S S S G 1 2 SERIAL 1 2 3 4 5 1 2 3 4 5 24 V DC PWR IN G IR SERIAL 4 3 2 1 S G S G S G S G G OUT 5 V DC LAN SYSTEM DEFAULT Output 5 VDC Audio line output A...

Страница 18: ...nector pin out RJ 45 Pin Signal Cat5 Cable Color 1 TX_D1 and PoE White Orange 2 TX_D1 and PoE Orange 3 RX_D2 and PoE White Green 4 Blue 5 White Blue 6 RX D2 and PoE Green 7 White Brown 8 Brown Direct...

Страница 19: ...Panel choose the option to switch to Classic View 3 Double click Network Connections Following steps are 1 Right click on network adapter used for connection with touch panel controller and then right...

Страница 20: ...the power supply unit to the PWR IN connector located on the rear panel and attach power cable to a power outlet Warning Use any unit only with the power adapter supplied in the product package Using...

Страница 21: ...RS 232 Request to Send From uniCUE 3 GND Ground 4 RxD RS 232 Received Data To uniCUE 5 CTS RS 232 Clear to Send To uniCUE RS 422 Mode This mode must be set in the programming application Connector pin...

Страница 22: ...ependent outputs for example three outputs can be used as IR five outputs can be used as RS 232 Connector pin out IR SERIAL 2 pin 3 5 mm Pin Signal Description S G S Signal IR Serial Signal Output G G...

Страница 23: ...O independently I O voltage with pull up on is approx 4 3 VDC because protection diode is connected in series 0 7 V dropdown Analog input is rated 0 5 VDC Analog to digital A D converter has 10 bits p...

Страница 24: ...3 5 mm Pin Description C NO NC NC Relay Contact Normal Close C Relay Contact Common NO Relay Contact Normal Open AUDIO LINE IN This connector provides unbalanced line level audio Connector pin out AUD...

Страница 25: ...485 can be used for CUEwire connection Unlike controllers the uniCUE isn t equipped with 24 V output that means all CUEwire devices must be powered externally See following figure for CUEwire device...

Страница 26: ...apter Connecting CUEnet LAN 2 Run Cue Visual Composer on your PC 3 Open appropriate project in Cue Visual Composer It s necessary to have appropriated touch panel controller properly inserted and conf...

Страница 27: ...cation dialog box 5 Be sure your touch panel controller is checked 6 Use button Export All to export application and store it in file cvca 7 Run the Internet browser on your PC and type in the same to...

Страница 28: ...uniCUE to your PC as described in the chapter PC Connection 2 Arrange IR remoter and touch panel as described below IR remoter 3 Start Cue Visual Composer and capture IR codes by standard way 4 Push S...

Страница 29: ...onfiguration Identification Name Empty Not changed IP settings Host name Empty Not changed IP address 192 168 1 128 192 168 1 128 Subnet mask 255 255 255 0 255 255 255 0 Default gateway 192 168 1 1 19...

Страница 30: ...ication On Screen Display button launches menu described below Settings The Backlight Saver will switch off automatically display backlight Time in minutes can be set by buttons and Time set to 0 mean...

Страница 31: ...e than one unit a unique IP address must be given to each CUEunit For setting please select appropriate field using Edit button and then use numeric keypad Be sure to click the Apply button for any ch...

Страница 32: ...cation starts automatically after switch on the unit The running application can be stopped via the Stop button Files are uploaded from a personal computer to the touch panel using Cue Visual Composer...

Страница 33: ...n your PC and type in the touch panel IP address Factory default IP address is 192 168 1 128 The default password is empty IP Settings This page is used for establishing the communication parameters f...

Страница 34: ...NS server and secondary DNS server manually by entering your changes into the appropriate boxes DHCP is not supported in this release Be sure to click the Apply button for any changes to become effect...

Страница 35: ...e zone on your CUEunit The current date time and time zone are shown on the Current time line The time zone box can be selected to enter changes to the Time zone Be sure to click the Apply button for...

Страница 36: ...from the CUEunit to a personal computer by clicking the File name Files are easily deleted with the Delete button The button Total stop stops a running application This application will not be automa...

Страница 37: ...utes can be set Time set to 0 means that Backlight Saver is disabled LCD Backlight sets display backlight level If Adaptive Brightness is switched to Yes the light sensor automatically adjusts display...

Страница 38: ...y default settings click the Format data area button This will remove all data including Applications and File storage files Configuration will be cleared including IP address password and touch scree...

Страница 39: ...copies of all applications files and folders from a backup archive on the PC to their corresponding locations on the CUEunit To start the restore process select the desired backup archive then click...

Страница 40: ...40 Touch Panel Controllers Admin Web CUE a s All Rights Reserved Reset To restart your CUEunit click the Reset button License This page describes software license...

Страница 41: ...icense You agree that any copies of the Software will contain the same proprietary notices which appear on and in the Software Prohibited Uses Without obtaining prior written permission from CUE You m...

Страница 42: ...42 Touch Panel Controllers Notes CUE a s All Rights Reserved Notes...

Страница 43: ...43 Touch Panel Controllers Notes CUE a s All Rights Reserved...

Страница 44: ...CUE a s K Nouzovu 6 143 00 Praha 4 Czech Republic www cuesystem com support cuesystem com...

Отзывы: