Use and operation

24

EN-US

Cubusan CP120

5.3 Site selection

For optimum operation of the device, an ambient temperature of 18°C bis 24°C at medium dust concentration is

 

recommended. Recommended room size for the CUBUSAN 

120 m3 (corresponds to approx. 50 m2 at 2.5 m room 

height)

.

n

Place the device on a stable surface and at a minimum distance of 15 cm from the nearest vertical surface, such as

a wall or cabinet with sufficient air supply.

n

Do not position the device directly next to a stove, a heater, or near a window with direct sunlight.

n

The device must not be operated outdoors or in explosion-risk areas.

n

Do not position the device near a humidifier.

n

A suitable mounting plate is required for wall or ceiling mounting. If desired, this can be obtained from WINTER-

STEIGER.

n

Do not use the device within reach of children. The device must be at least 1 meter above the floor.

n

Before moving the CUBUSAN , unplug the power adapter.

The best result is achieved when the CUBUSAN is placed centrally in the room. The more
centrally the CUBUSAN is positioned, the more even the distribution.
For high rooms, rooms over 120 m³ , or rooms with strong ventilation, the use of several
air purifiers may be necessary. We recommend discussing this with the manufacturer. 
The air exchange per hour should not be more than 4 times the air in the room.

5.4 Operation

The  CUBUSAN  has  several  openings/slits  for  the  air  inlet/air  outlet,  which  must  not  be  covered  under  any
circumstances.  Make  sure  that  none  of  these  openings  are  covered  during  installation.  Keep  a  distance  of
150 mm between the openings and any objects on all sides so that the device can blow out air freely.

1.

Plug the cable of the power adapter output into the bottom of the CUBUSAN CP-120 and the power adapter into an
outlet 

(see chapt. Commissioning, page 23)

.

2.

The fan in the device starts to work and sucks in air, which is disinfected and freed from odors with the help of the
STEREX technology. The decorative lighting on the corners of the CUBUSAN CP-120 lights up permanently.

3.

Unplug the device as necessary.
The power supply to the CUBUSAN CP-120 can only be completely disconnected by pulling out the power adapter.

Ideally, plug in the device at least 1 hour before you want to disinfect the air. 
A smell of freshness can be detected when the device is being properly operated.

Содержание CP120

Страница 1: ...Cubusan CP120 Instruction manual EN US 78 560 014 25 11 2021 ...

Страница 2: ...ns 21 4 3 Safety instructions for transportation 21 4 4 Safety instructions for maintenance servicing and troubleshooting 21 4 5 Storage 22 4 6 Views and design 22 5 Use and operation 23 5 1 Function 23 5 2 Commissioning 23 5 3 Site selection 24 5 4 Operation 24 6 Care and maintenance 25 6 1 Care 25 6 2 Inspection refresh by the manufacturer 25 6 3 Clearing faults 25 7 Appendix 27 7 1 Technical da...

Страница 3: ...to exercise industrial property rights 1 1 Note on use We expressly point out that the use of the Cubusan is only complementary to an effective hygiene concept and does not replace other hygiene measures When using the Cubusan always observe the manufacturer s instructions for use and the specified minimum square me ters per person without exception In particular WINTERSTEIGER shall not be liable ...

Страница 4: ...perating maintenance and service stipulations set out by the manufac turer The applicable accident prevention regulations and other generally accepted safety and occupational health regulations shall also be adhered to Any changes to the device by the user renders manufacturer liability null and void with regards to any resulting damages We constantly try to improve our products and therefore rese...

Страница 5: ...medium degree of risk which if not prevented could cause death or serious injury CAUTION describes a hazard with a low degree of risk which if not prevented could re sult in a slight or moderate injury This symbol indicates special information on practical work or a general recommendation Device damage This symbol indicates possible damage to destruction of the product the process and or its surro...

Страница 6: ... 2 General safety instructions n The device must not come into contact with water or excessive moisture during operation or storage see chapt Technical data page 27 n Any applicable accident prevention specifications and other generally accepted safety and medical regulations are to be obeyed n The device may only be used if it is in a flawless technical condition and only according to the intende...

Страница 7: ...tems and may per form work on them 4 5 Storage n Devices and components must not be stored outdoors n Store the device in its original packaging inside a building only at a temperature of 5 C to 30 C and a maximum relative humidity of 60 To avoid damage never place any other packages or items on top of the packaged unit 4 6 Views and design 1 2 3 4 5 Front view Underside 6 7 8 1 Air outlet 5 Fixin...

Страница 8: ... n The plasma air mixture generated by the STEREX technology eliminates bacteria viruses germs etc that are in the air by 99 99 You can therefore be sure that the air in a 50 m room with a room height of approx 2 5 m will be cleaned after a short time The disinfection effect during continuous operation of the device 60 min continuous disinfection has therefore been proven to eliminate up to 99 99 ...

Страница 9: ... even the distribution For high rooms rooms over 120 m or rooms with strong ventilation the use of several air purifiers may be necessary We recommend discussing this with the manufacturer The air exchange per hour should not be more than 4 times the air in the room 5 4 Operation The CUBUSAN has several openings slits for the air inlet air outlet which must not be covered under any circumstances M...

Страница 10: ...mmend that the plasma unit is in spected refreshed by the manufacturer after 25 000 operating hours with average use 8 hrs day x 365 days 25 000 hrs 8 5 years Depending on the operating environment and especially when the device is used in ex treme conditions the performance of the STEREX plasma unit may reduce in a shorter time than originally anticipated If there is no longer any noticeable air ...

Страница 11: ...d that there are no foreign bodies at in the air outlet at the top all round the de vice Device is being operated in a location that does not comply with the specifi cations Position the device in a suitable location see chapt Site selection page 24 Fan defective Have the device checked repaired by the manufacturer 4 Odor in room Insufficient supply of fresh air to the room Increase the fresh air ...

Страница 12: ...e electrical and electronic equipment WEEE this device must not be disposed of with household waste Similarly this also applies to countries outside the EU according to the applicable national regula tions n Dispose of this device in accordance with local regulations in a separate collection for electrical and electronic equipment If you have any questions please contact the relevant authority or ...

Страница 13: ...Appendix 28 EN US Cubusan CP120 ...

Отзывы: