Cubix Corporation 

 2800 Lockheed Way 

 Carson City, NV 89706-0719 

 Page 3 

Sales 800.829.0550 

 

http://www.cubix.com

 

 [email protected] 

 he5urp25-x11dai-n-12g20181016 

2 x USB 3.1 (Type-A and Type-C 10.0Gbits/sec) 

Cooling Fans 

Maximum air flow each 

178 cubic feet / minute (cfm) 

Remove / Replace 

Hot-plug 

AC Power Supply 

One single-phase, auto-ranging, 100-240VAC, 45-24Amps, 50/60Hz 
with 3 + 1 x 1,280Watt redundant modules; total output power is not 
to exceed 3,840Watts  

Operating Environment 

0° to 30° Celsius (32° to 86° Fahrenheit) temperature 
5% to 80% non-condensing humidity 

Altitude 

Maximum 

Operating 

10,000ft (3,050meters) 

Storage 

50,000ft (15,240meters) 

Dimensions 

8.75

” H x 19.00” W x 28.00” D (22.22cm H x 48.26cm W x 71.12cm D) 

Weight 

49.00 lbs. (24.50kg) 

Warranty / Period 

Parts & labor return to manufacturer / 2 year 

 

Ext. Warranty Period 

Optional 3

rd

 year 

 
 
Memory Configuration

 

 
 

Memory Population Guidelines 

Use DDR4 DIMMs only. 
Do not mix LRDIMMs and RDIMMs. 
Do not mix 3DS and non-3DS 
LRDIMMs. 
If only one DIMM is populated in a 
channel, use the slot furthest from 
the CPU. 
 
 
 

DIMM Configurations for CPU1 Only 

# DIMMs 

Location 

Memory Scheme 

P1-DIMMF1 

P1-DIMMC1 
P1-DIMME1 
P1-DIMMB1 

Interleaved 

 DIMMs must be identical 

type and speed

 

P1-DIMMF1 

P1-DIMMC1 
P1-DIMME1 
P1-DIMMB1 
P1-DIMMA1 
P1-DIMMA2 
P1-DIMMD1 
P1-DIMMD2 

DIMM Configurations for CPU1 and CPU2 

16 

P1-DIMMF1 

P1-DIMMC1 
P1-DIMME1 
P1-DIMMB1 
P1-DIMMA1 
P1-DIMMA2 
P1-DIMMD1 
P1-DIMMD2 
P2-DIMMC1 

P2-DIMMF1 

P2-DIMMB1 
P2-DIMME1 
P2-DIMMA1 
P2-DIMMD1 
P2-DIMMA2 
P1-DIMMD2 

Interleaved 

 DIMMs must be identical 

type and speed 

Содержание HostEngine 5URP24

Страница 1: ...24 To support the 24 x Serial Attached SCSI SAS with 12Gbits second or 12Gbps transfer rate 2 5 or 3 5 hot plug hard disk drives HDDs requires 1 x 24 port or 2 x 12 port SAS 12Gbps RAID controller s in one or two of the 8 x slots Each RAID controller port connects to a 4 port SAS backplane with a 1 0meter SFF 8643 mini SAS to SFF 8643 mini SAS HD cable and in turn each 4 port SAS backplane connect...

Страница 2: ...s 2 x PCIe 3 0 x4 from CPU 1 each requires 1 x data power cable kit System BIOS AMI User Extensible Firmware Interface UEFI BIOS Feature Support Advanced Configuration and Power Interface ACPI 3 0 4 0 USB keyboard Plug n Play PnP Serial Peripheral Interface SPI dual quad speed System Management BIOS SMBIOS 2 7 or later Ethernet ports 2 x Intel RJ 45 ports supported by PCH C621 1 x port shared by A...

Страница 3: ...0 D 22 22cm H x 48 26cm W x 71 12cm D Weight 49 00 lbs 24 50kg Warranty Period Parts labor return to manufacturer 2 year Ext Warranty Period Optional 3rd year Memory Configuration Memory Population Guidelines Use DDR4 DIMMs only Do not mix LRDIMMs and RDIMMs Do not mix 3DS and non 3DS LRDIMMs If only one DIMM is populated in a channel use the slot furthest from the CPU DIMM Configurations for CPU1...

Страница 4: ...r double wide accelerators like NVIDIA Quadro Series or AMD Firepro W Series use slots 1 3 and 5 If you add a single wide display controller like AMD Firepro W2100 W4100 or NVIDIA Quadro P4000 for connecting one or more 4K UHD displays use a PCIe x16 slot For SAN controllers which usually provide PCIe Gen 3 x8 connectivity use CPU2 Slot 4 or Slot 6 Remove and replace PCIe devices PCIe devices can ...

Страница 5: ...place the front panel Remove Replace HostEngine HostEngine can be removed and replaced from the front once you remove power Power down gracefully using the OS or the front panel on off switch Wait for the power to shut off Disconnect power and all other cables from HostEngine Loosen the two retention screws on the HostEngine front panel Gently tug the HostEngine handles toward you Extract the Host...

Страница 6: ...mediately above or below GPU Xpander Rackmount 8 You can also install PCIe cards inside HostEngine 4U For example install 4 x full length full height double wide GPUs inside HostEngine 4U On the front panel HostEngine provides 2 x local USB ports Troubleshooting Procedure Issue The Cubix HIC in HostEngine is linking at x8 or x4 or at Gen 2 with Cubix Xpander and not linking at the specified PCIE G...

Страница 7: ... the following setting in HostEngine system BIOS Advanced PCI Plug n Play Above 4G Decoding Enabled Issue How can I tell whether each GPU in Xpander connected to HostEngine is running at optimal bandwidth Resolution Download Cubix GPU Manager for either Linux or Microsoft Windows http www cubix com gpumanager and install it Documentation is on line here Issue Resolution ...

Отзывы: