Electrical
6
‐
8
Checking the switch
Use a multimeter to check the terminals
for continuity. If the continuity is faulty at
any point, replace the switch.
Note:
•
Set the multimeter
to “0” before
starting the test.
•
The multimeter
should be set to the
“
Ω
× 1” range when testing the switch
for continuity.
• Turn the switch on and off a few times
when checking it.
The terminal connections for switches
(main switch, light switch, etc.) are shown
in a chart similar to the one on the right.
This chart shows the switch positions in
the column and the switch lead colors in
the top row.
For each switch position, “-” indicates the
terminals with continuity.
The example chart shows that:
①
There is continuity between the
“Brown/Blue and Red” leads when the
switch is set to “ON”.
Содержание Challenger 500
Страница 1: ...SERVICE MANUAL Challenger 500 Challenger 700...
Страница 50: ...500 UV Engine Specifications 2 10...
Страница 51: ...500 UV Engine Specifications 2 1 1...
Страница 52: ...500 UV Engine Specifications 2 12...
Страница 53: ...500 UV Engine Specifications 2 13...
Страница 209: ...Electrical 6 11 Ignition System Circuit Diagram 1 High tension coil 2 C D I 3 Magneto...
Страница 213: ...Electrical 6 15 Electric Starting System...
Страница 216: ...Electrical 6 18 Charging System...
Страница 218: ...Electrical 6 20 Lighting System...
Страница 219: ...Electrical 6 21 Signaling System...
Страница 220: ...Electrical 6 22 Cooling System...
Страница 221: ...Electrical 6 23 2WD 4WD Selecting System...
Страница 244: ...MTD Products Inc Product Training and Education Department FORM NUMBER 769 10856 05 2015...