background image

Trademarks 

 

CTS is a registered trademark of Connection Technology Systems 
Inc. Contents subject to revision without prior notice. 
 
All other trademarks remain the property of their owners. 
 

Copyright Statement 

 

Copyright 

 Connection Technology Systems Inc. 

 

This  publication  may  not  be  reproduced  as  a  whole  or  in  part,  in 
any way whatsoever unless prior consent has been obtained from 
Connection Technology Systems Inc. 
   

FCC Warning 

 

WPS/MPS-2006  Series  Ethernet  Switches  have  been  tested  and 
found  to  comply  with  the  limits  for  a  Class  A  digital  device, 
pursuant  to  Part  15  of  the  FCC  Rules.  These  standards  are 
designed  to  provide  reasonable  protection  against  harmful 
interference  when  these  devices  are  operated  in  a  commercial 
environment. These devices generate, use, and can radiate radio 
frequency  energy  and  may  cause  harmful  interference  to  radio 
communications  unless  installed  in  accordance  with  this  User’s 
Guide. Operation of these devices in a residential area is likely to 
cause  harmful  interference  which  will  make  the  user  responsible 
for the appropriate remedial action at his / her own expense. 
   

CE Mark Warning 

 

These  are  Class  A  products.  In  a  domestic  environment  these 
products may cause radio interference in which case the user will 
need to consider adequate preventative methods. 

 
 

1. Checklist 

The package should contain the following items: 
 

-  WPS/MPS-2006 Ethernet Switch 
-  User

’s Guide 

-  Installation Guide 

 
Please notify your sales representative immediately if any item is 
missing or damaged. 
 
As for power adapters, please refer to Section 7 for more detailed 
information. 
 
 
 
 

2. Overview 

WPS/MPS-2006  Ethernet  Switches  support  IEEE802.3at  PoE 
feature  and  are  specifically  designed  to  supply  power  to 
PoE-enabled  devices  such  as  WiFi  AP  or  surveillance  cameras. 
They  are  power  supply  equipments  (PSE)  that  can  transmit  data 
and supply power at the same time to the powered devices (PD). 
The maximum cable distance that can reach the powered devices 
from the switch is up to 100M, allowing your powered devices to be 
installed in a place where power is not easily accessible.   
 
Besides,  WPS/MPS-2006  Series  Ethernet  Switches  aim  at 
industrial  applications  that  demand  wide  range  of  operating 
temperature  and  require  redundant  power  supplies  to  create  a 
reliable and stable  networking  environment  in  the  event  of  power 
failure. They can also be mounted on the wall or onto 35mm DIN 
rail using DIN rail clip on the Switch. The installation and operation 
procedures  are  simple  and  straightforward.  Operation  status  can 
be  locally  monitored  through  a  set  of  diagnostic  LED  indicators 
located on the front panel.

   

 

Major Features: 

 
 
 
 

3. Network Installation 

Please follow the steps described below and refer to Figure 1 and 
2 to complete the network installation. 
 

 

Attach fiber cable from the Switch to the fiber network. 

 

Attach  a  UTP  cable  from  the  10/100Base-TX  network  to  the 
RJ-45 port on the Switch. 

 

Connect the power adapter to the Switch and the Power LED 
will light up. The Link/ACT/Speed and F/O Link/ACT LEDs will 
light up as soon as all the cable connections are satisfactory. 

 
 

 
 
 
 

WPS-2006                                                          MPS-2006   

 

 

Figure 1. Network Installation for FX Models 

 
 

WPS-2006                                                          MPS-2006   

 

 

Figure 2. Network Installation for WDM/SFP Models

 

 
 

4. Terminal Block 

TB1 and TB2 Power Supply: 

There are two pairs of contacts on 

the  terminal  block  connector  for  power  redundancy  purpose.  You 
can use both pairs of power supply for redundancy purpose or use 
either  one  pair  of  power  supply  on  the  terminal  block  and  AC 
external  power  supply  to  create  redundant  setup.  The  redundant 
power supply will take over seamlessly when one power source is 
down  to  protect  your  device  or  network  from  the  loss  of  power. 
When  you  use  only  one  power  supply  (no  redundant  power  is 
available),  the  LED Power/Port  Status  will  flash  in  orange to  alert 
the user. 
 
 

 

 
 

Figure 3. Terminal Block Front and Top View 

 
Port Fault Alarm:

    One pair of port fault connection on the 

terminal block is used to connect alarm devices such as speakers 
or LEDs to alert users when the F/O port link is disconnected.   
 

-  Auto-Negotiation in TP port 
-   Store and Forward Switching Mechanism 
-   Support Full/Half duplex mode operation 
-  Support MDI/MDIX Auto-Crossover 
-  Support Flow Control 
-   Support alarms for power and F/O port failure 
-   Support 2K MAC address table 
-   Support 80K bytes Memory Buffer 
-   Support wide range of operating temperature (-20

o

C~60

o

C) 

-   Support DIN Rail and Wall Mounting 

-   Support redundant AC and DC power supply 

Use flat-head 
screwdriver to   
loosen and tighten 
the screw. 

Insert positive or 
negative wire as 
indicated. 

Отзывы: