Utility D15
Previous to serial number 17000 this connector was left N/C for custom applications. From this serial
number onwards the unit has two GPI relay outputs active when Comm A or Comm B are ‘on air’. This
allows remote control of On Air lights etc. Connections are:
Pins 1 and 9 short when Comm A is On Air. Pins 2 and 10 short when Comm B is On Air.
Contacts rated at 30 volts at 0.5A DC.
Mil 26 connector pinout.
Please note that by popular request these Mil 26 pinouts have been
altered as from DC2012 serial number 9692 to match the DC99-II
Commentary box
.
Male connector fitted to rear of comms box.
PIN H/C/Sc PAIR
FUNCTION
A
H
1
Comm A out
B
C
T
S
C
H
2
Comm B out
D
C
U
S
E
H
3
Director lazy out
F
C
V
S
G
H
4
Aux 1 lazy out
H
C
W
S
J
H
5
Input talkback
K
C
X
S
L
H
6
Input Prog
M
C
Y
S
N
H
7
Input aux 1
P
C
Z
S
R
H
8
Input Aux 2
S
C
a
S
b
not used
c
not used
Содержание DC2012
Страница 1: ...DC2012 Commentary Box Instruction Manual by CTP Systems Revised 1 4 2018...
Страница 10: ......
Страница 11: ......