Audio Metering
The meter has a slightly wider band to show the position of -18dBFS. Each of the pips
are 4dB apart so the meter will show from -38dBFS to -6dBFS accurately. The meter
is active at all times except when setting up the unit.
Display
The display normally shows the text On-Air, microphone settings and metering.
When a talkback button is pressed the unit will display whichever key is pressed (or
both). If a mute key has been programmed then the display will flash ‘Mic Muted’.
S
etting up the B-D2020
To enter setup mode press the Setup button for 3 seconds. The display will change to
show the current microphone amplifier gain. Press the talk ksys (+ or -) to get to the
required setting. Press the button once for adjusting in 1dB steps or press and hold
the required button and the display will scroll fater through the gain settings.
When adjusted as required press the setup button again, the display will now show
phantom power on or off. Press the + or – keys to adjust.
Press again to adjust the microphone limit level range 0dBFS to -20dBFS.
Press again to set key1 function. These are:
1 - Momentary action. Only diverts audio while the button is pressed.
2- Latching action. When pressed audio will be diverted until the button is pressed
again. The switch will illuminate red when active.
3- Disabled. The key does not operate.
4- Mute momentary. The key can be used as a ‘cough key’. The on-air microphone is
switched off but audio is not routed anywhere. ‘Mic Muted’ will flash on the display
when pressed.
5- MuteLatch. As above but with an off off latching action. Again, ‘Mic Muted’ will
flash on the display while the button is latched on and the button will illuminate.
Press again to set key2 function, details as key1.