 Installation instructions/User instructions

Mkomfy R-T 25A

SAVE THESE INSTRUCTIONS

 Panel-installed cooker guard relay

Mkomfy set with sensor and relay 

is supplied ready paired and ready for use

Fulfils the requirements 
of NEK 400:2014

Содержание Mkomfy R-T 25A

Страница 1: ...structions User instructions Mkomfy R T 25A SAVE THESE INSTRUCTIONS Panel installed cooker guard relay Mkomfy set with sensor and relay is supplied ready paired and ready for use Fulfilstherequirement...

Страница 2: ...ensor is removed from its bracket a safety function is activated which cuts off the power to the cooker On activation the sensor will beep once a second for 5 seconds before disconnecting the cooker T...

Страница 3: ...he timer function can be temporarily changed from 2 hours operating time to 12 hours operating time This is done by pressing the function button for 10 seconds The sensor acknowledges this with two so...

Страница 4: ...en necessary This is done by 2 short sound signals every 5 minutes 1 Flip the cooker guard away from the wall 2 Loosen two screws on the rear and remove the cover 3 The batteries can then be turned ou...

Страница 5: ...ke sure it is dry before pressing the cooker guard into place at the correct height remove the backing tape The adhesive foot must be fixed to the cooker guard Installation information 40 to 50 cm 30...

Страница 6: ...and set slide switch 4 to position ON Slide switch 2 Point the sensor eye marked towards your own face forehead and check that the cooker turns off the temperature of your forehead is over 30 C Sensor...

Страница 7: ...r 20 seconds in the event of overheating rather than the standard 40 seconds Extra high temperature To be carried out only by an authorised installer In certain locations or with certain types of hob...

Страница 8: ...the cooker guard relay for 5 seconds by turning the relevant fuse circuit off and on NB This must be done within one minute of connecting the relay under Point 2 or the pairing will not be saved 4 Set...

Страница 9: ...ected Flashes if there is no communication with the sensor Red Flashes when paired units are deleted or if the command from the sensor is rejected Yellow Flashes when the relay is set to pairing mode...

Страница 10: ...h a sound signal and red flash R T 25A Prog N N L L IN LOAD CONTACTOR Can also control a contactor This is recommended when the RC circuit is mounted in parallel with the coil on the contactor Install...

Страница 11: ...minutes NB Make sure you have new batteries to hand Alarm signal Three 3 sound signals every 5 seconds lasting for 40 seconds and the LED flashes Cause Overheating Action Press the button and take ac...

Страница 12: ...Tel 47 72831611 El No Name 6251698 Mkomfy R T 25A Technical data Mkomfy Komfyrvakt R T 25A Voltage 230 VAC 10 Max load 25 A Physical dimensions sensor 96x66x28 mm Timer 2 hours 12 hours Battery type...