background image

BATTERY TYPES 

The following recommendations should only be considered as guidelines. In the event of 
uncertainty always refer to the battery manufacturer’s recommendations.
CTEK XC 800 is suitable for charging all types of 6V lead-acid batteries: open batteries, MF, 
AGM and most GEL-batteries. Battery sizes from 1.2 to 32Ah. The charger can maintain 
batteries up to 100Ah. 

CHARGING

Charging batteries mounted in a vehicle:

1. The power cord should be disconnected before connecting or disconnecting the battery 
leads.
2. Identify the pole that is grounded (attached to the chassis). Ground is normally connected to 
the negative terminal.
3. Charging a negatively grounded battery. Connect the red wire to the positive pole of the 
battery and the black cable to the vehicle’s chassis. Be careful not to connect the black cable in 
the vicinity of a fuel pipe or the battery. 
4. Charging a positively grounded battery. Connect the black wire to the negative pole of the 
battery and the red cable to the vehicle's chassis. Be careful not to connect the red cable in the 
vicinity of a fuel pipe or the battery. 

Charging of a battery not connected to a vehicle:

1. The power cord should be disconnected before connecting or disconnecting the battery 
leads.
2. Connect the red wire to the positive pole of the battery and the black cable to the negative 
pole.

Connecting the provided cables with eyelet terminals:

Make sure that the cable is not being pinched or in contact with warm surfaces or sharp edges. 
When the cable is mounted on the battery, it should not be connected to the charger. Connect 
the eyelet terminals to the battery's poles – the red cable to the positive pole and the black 
cable to the negative pole. After this, the quick contact can be connected.

Reverse Polarity Protection

If the battery cables are connected incorrectly, the reverse polarity protection will make sure that 
the charger and the battery are not damaged. In this case, the red warning lamp 

 will be lit. 

Содержание XC 800

Страница 1: ...CTEK XC 800 Battery charger For lead acid batteries 1 2 100Ah User Manual and guide to professional battery charging for Starter and Deep Cycle batteries GB ...

Страница 2: ... into contact with water Never charge a frozen battery Never charge a damaged battery Do not place the charger on the battery while charging The electrical connection must fulfil the national heavy current requirements Check the cabling in the charger before use Make sure there are no cracks in the cabling or in the protective covering A charger with damaged cables may not be used Always check tha...

Страница 3: ...ively grounded battery Connect the black wire to the negative pole of the battery and the red cable to the vehicle s chassis Be careful not to connect the red cable in the vicinity of a fuel pipe or the battery Charging of a battery not connected to a vehicle 1 The power cord should be disconnected before connecting or disconnecting the battery leads 2 Connect the red wire to the positive pole of ...

Страница 4: ...YHKLFOH RX VKRXOG DOZD V GLVFRQQHFW WKH EDWWHU OHDG IURP WKH FKDVVLV EHIRUH you disconnect the other battery lead I WKH FKDUJLQJ ODPS DQG PDLQWHQDQFH FKDUJLQJ ODPS DOWHUQDWHO ÀDVK WKH UHDVRQ IRU WKLV LV the following I WKH ODPSV ÀDVK D IHZ WLPHV SHU VHFRQG WKHQ WKH EDWWHU LV SUREDEO VXOSKDWHG I WKH ODPS ÀDVKHV PRUH WKDQ PLQXWHV WKH EDWWHU VKRXOG EH UHSODFHG I WKH ÀDVKLQJ RFFXUV ZLWK D IHZ PLQXWHV ...

Страница 5: ...een 95 and 100 The battery receives a pulse when the voltage drops Keeps the battery in perfect condition when it is not used The charger can be connected for months at a time If possible check the water level in the battery TEMPERATURE PROTECTION CTEK XC 800 is protected from being overheated The power will be reduced if the ambient temperature is raised MAINTENANCE The charger is maintenance fre...

Страница 6: ... SPECIFICATION Voltage AC 170 260VAC 50 60Hz Back current drain 1Ah month Voltage Charging Voltage Nominal 6V 7 2V Ripple Max 10mV rms max 12mA Current 0 8A max Ambient Temperature 20 C to 50 C power is reduced automatically at increased ambient temperature Cooling Natural convection Charging cycle CTEK XC 800 is a multistage fully automatic charger Type of batteries All types of 6V lead acid batt...

Страница 7: ...following EMC standards EN 55011 EN 61000 3 3 EN 61000 3 2 EN 55014 1 and EN 55014 2 according to the terms of directive 89 336 EEC with the addition of 92 31 EEC and 93 68 EEC The charger comes in different models with different types of electrical plugs The charger with WKH ÀDW HXURFRQWDFW LV LQWHQGHG IRU 6ZLW HUODQG VIKMANSHYTTAN SWEDEN 2006 01 23 Börje Maleus VD CTEK SWEDEN AB Rostugnsvägen 3 ...

Отзывы: