INTRODUCTION

Congratulations on purchasing your new professional switch mode battery 

charger. This charger is included in a series of professional chargers from 

CTEK SWEDEN AB and represents the latest technology in battery charging.  

Please read this user´s manual and follow the instructions carefully.

SAFETY

• 

The charger is designed for charging 12V lead-acid batteries. Do not use the 

charger for any other purpose.

• 

Battery acid is corrosive. Rinse straight away with water if acid comes into contact 

with skin or eyes, and seek immediate medical advice.

• 

Ensure that the cabling does not jam or comes into contact with hot surfaces or 

sharp edges.

• 

A battery being charged could emit explosive gasses, which is why it is important 

to prevent sparks close to the battery. When batteries are reaching the end of their 

lifecycle internal sparks may occur. 

• 

Always provide for proper ventilation during charging.

• 

Avoid covering the charger. 

• 

Ensure that the mains cable is not exposed to water. 

• 

Never charge a frozen battery.

• 

Never charge a damaged battery.

• 

Never place the charger on top of the battery when charging.

• 

Connection to the mains supply must be in accordance with the national 

regulations for electrical installations. 

• 

Check the charger cables prior to use. Ensure that no cracks have occurred in 

the cables or in the bend protection. A charger with damaged cables must not be 

used.

• 

Always check that the charger has switched to maintenance charging mode before 

leaving the charger unattended and connected for long periods. If the charger has 

not switched to maintenance charging within 72 hours, this is an indication of an 

error. In such cases the charger must be disconnected manually.

• 

All batteries fail sooner or later. A battery that fails during charging is normally 

taken care of by the chargers advanced control, but some rare errors in the 

battery could still exist. Don’t leave any battery unattended for a longer period of 

time.

• 

This appliance is not designed for use by young children or people who cannot 

read or understand the manual unless they are under the supervision of a 

responsible person to ensure that they can use the battery charger safely. Store 

and use the battery charger out of the reach of children, and ensure that children 

cannot play with the charger. 

• 

Batteries consume water during use and charging. For batteries where water can 

be added, the water level should be checked regularly. If the water level is low add 

distilled water.

Содержание MULTI XS 4003 1035

Страница 1: ...I XS 4003 Battery charger For lead acid batteries 1 2 140Ah User s Manual and a guide to professional battery charging for starter deep cycle batteries Model 1035 QUICK GUIDE EN DE FR ES IT NL SE DK N...

Страница 2: ...d to the positive pole of the battery and the black lead to the negative pole QUICK GUIDE MULTI XS 4003 When you are sure the battery leads are correctly placed connect the charger to the wall socket...

Страница 3: ...ged Ready to use Snowflake Battery size 14 140Ah Recond Battery size 14 140Ah Settings are made by pressing the MODE button and stepping forward one press at a time until the required mode is reached...

Страница 4: ...s supply must be in accordance with the national regulations for electrical installations Check the charger cables prior to use Ensure that no cracks have occurred in the cables or in the bend protect...

Страница 5: ...e for wet batteries MF and for most GEL batteries 14 140 Mode 14 7V 4A This mode is recommended for charging batteries at temperatures lower than 5 C It is also recommended for many AGM batteries This...

Страница 6: ...batteries that are fitted in vehicles 1 The mains cable should not be connected to the wall socket when connecting or disconnecting the battery leads 2 Identify the pole that is earthed connected to c...

Страница 7: ...arging cycle This means that if the battery is in a state of deep discharge the charger will be unable to charge the battery in question Another reason could be lack of power from the wall socket Star...

Страница 8: ...that you have chosen the Recond Maintenance charge Float Charging with constant voltage Maintenance charge Pulse The state of charge varies between 95 and 100 The battery receives a pulse when the vol...

Страница 9: ...Vp p and 160mAp p Ambient temperature 20 C to 50 C output power is reduced automatically at high temperatures Cooling Natural convection Charger type Eight step fully automatic charging cycle Battery...

Страница 10: ...ests the state of the battery Main charge Top charge and minimal fluid loss YES 4A for max 8h until the voltage reaches 12 6V 4A for max 20h A combination of current limits and timers max 10h YES 0 8A...

Страница 11: ...9V max voltage 14 4V Note In snowflake mode MULTI XS 4003 follows the same program as CAR but with a higher voltage 14 7V The product is protected by the following Patents EP1618643 SE525604 US754177...

Страница 12: ...n those mentioned above i e no consequential damages Moreover CTEK SWEDEN AB is not obligated to any other warranty other than this warranty DECLARATION OF COMPLIANCE CTEK SWEDEN AB Rostugnsv gen 3 SE...