If the battery is charged and/or the battery's terminal voltage drops below 12.9 V the char-

ger starts a charge pulse of 5A until the terminal voltage has reached the set level, 14.4 

V or 14.7 V. The charge pulse is then interrupted and the cycle is repeated as long as the 

charger is in pulse maintenance phase. Pulse maintenance phase is indicated by lamp 4. 

If the terminal voltage drops below 12.1 V, the charger automatically reverts to the begin-

ning of the charging curve.

Setting : Supply 13.6 V

MULTI US 7000 has a Supply mode setting which has a constant voltage at 13.6 V and 

current up to 7 A. It could be used for maintenance charge using the Float approach. This 

approach

 

keeps the battery at 100 % State of Charge, but the constant small

 

overcharge 

also increases water loss. Note that there is no need for a battery to be connected at this 

mode. 

Note: The Spark protection system and the indication of Reverse Polarity is 

suppressed in this mode. The Short Circuit protection is still working.

It is not advisable to charge a discharged battery in Supply mode as this will not provide a 

complete charge. In this mode, MULTI US 7000 can also be used as a power-generation 

unit for operating equipment that requires 13.6 V and a maximum of 7 A. If the selected 

current exceeds 7 A, the output voltage will drop at an increasing rate. The charger has 

electronic overload protection in this mode, which is activated if the charge is so great that 

the output voltage from the charger falls below around 3.5 V and the current to around  

7 A. In the event of an overload, the charger transfers to error mode (lamp 0).

Setting lamp D indication lamp 5.

Setting: Recond 16 V / 1.5 A / 4 h

MULTI US 7000 has a Recond-setting which gives a constant current at 1.5 A, maximised 

at 16 V for 4 hours. It will automatically go over to 14.4 V pulse setting after a completed 

cycle. This mode is used for batteries that have been deep discharged. Start by charging 

at either the 14.4 V or 14.7 V setting until the battery is in Pulse maintenance phase. Set-

ting lamp E indication lamp 6.

Содержание MULTI US 7000

Страница 1: ...Switch Mode BATTERY CHARGER For lead acid batteries 14 150 Ah MULTI US 7000 User s Manual and a guide to professional battery charging For Starter Deep Cycle batteries US ...

Страница 2: ...ury to persons 5 To reduce risk of damage to electric plug and cord pull by the plug rather than by the cord when disconnecting charger 6 An extension cord should not be used unless absolutely necessary Use of an improper extension cord could result in a risk of fire and electric shock If extension cord must be used make sure that a Pins on plug of extension cord are the same number size and shape ...

Страница 3: ...r battery d If battery acid contacts skin or clothing wash immediately with soap and water If acid enters eye immediately flood eye with running cold water for at least 10 minutes and get medical attention immediately e NEVER smoke or allow a spark or flame in vicinity of battery or engine f Be extra cautious to reduce risk of dropping a metal tool onto battery It might spark or short circuit batter...

Страница 4: ...mine voltage of battery by referring to car owner s manual and make sure that the output voltage selector switch is set at correct voltage 14 CHARGER LOCATION a Locate charger as far away from the battery as battery charger cables permit b Never place charger directly above battery being charged gases from battery will corrode and damage charger c Never allow battery acid to drip on charger d Do n...

Страница 5: ...onnect negative charger clip black to negative battery terminal 2 Connect positive charger clip red to a good metal engine ground away from the battery Do no connect clip to fuel lines or sheet metal body parts 3 Connect the AC cord to the socket The red alarm indication light will indicate a battery which is connected to reverse polarity g When disconnecting charger disconnect AC cord remove clip...

Страница 6: ...ays check whether the charger has been switched to maintenance charge before you leave it turned on or unobserved for any length of time Caution If the MULTI US 7000 does not switch to maintenance mode after three days manually switch it to pulse maintenance mode If the set has been switched to maintenance charge then everything is in order Note A battery that hasn t changed to maintenance charge ...

Страница 7: ...e correct charge mode to be used for charging your battery in the section on SETTINGS 2 Once you have established that the battery cable has been correctly connected you can start the charging process To do so insert the charger plug into the AC socket 3 Now either the charge indicator or the maintenance charge indicator lights up When the maintenance charge indicator lights up the battery is full...

Страница 8: ...ost Gel batteries Some Gel batteries prefer a slightly lower charging voltage Please consult the battery manufacturer when in doubt Mode 14 7 V This setting is recommended for a battery at temperatures 5 degrees C It is also recommended for many AGM batteries like Optima and Odysseys Consult your battery manufacturer when in doubt SUPPLY Mode 13 6 V Supply The charger is operating at a constant vo...

Страница 9: ...arm indication light 0 will also indi cate if the charge cycle is activated without any battery connected to the battery leads 6 If nothing happens A bad connection of the battery to ground will be indicated by no indicator lights illuminating or that the indicator lamp is still in the Standby mode lamp A A bad battery will also be indicated in the same way Don t forget to check the wall outlet If...

Страница 10: ...he charge is carried out at maximum charge until full voltage is achieved Lamp 2 indicates this phase Absorption Final part of the charge The voltage is kept constant until the current has tapered to 0 6 A when the charger goes into Pulse Maintenance mode The phase is also ended if the total time for bulk and absorption exceeds 40 hours Lamp 3 indicates this phase Pulse Maintenance charge The stat...

Страница 11: ...s suppressed in this mode The Short Circuit protection is still working It is not advisable to charge a discharged battery in Supply mode as this will not provide a complete charge In this mode MULTI US 7000 can also be used as a power generation unit for operating equipment that requires 13 6 V and a maximum of 7 A If the selected current exceeds 7 A the output voltage will drop at an increasing ...

Страница 12: ... types and settings C Mode 14 7 V See battery types and settings D Mode 13 6 V Supply See battery types and settings E Mode 16 V 1 5 A 4 h Recond See battery types and settings Error mode The charger goes to error mode in the following situations 1 Charging is started without a battery with terminal voltage over 1 5 V being con nected to the terminals 2 The battery is connected with the battery s ...

Страница 13: ...ies All types of lead acid batteries Wet Maintenance Free VRLA AGM and most GEL Battery Capacity 14 150 Ah Dimensions 8 1 2 x 3 1 2 x 1 7 8 inches L x W x H Insulation Splashproof Rainproof Weight 1 7 lbs The back current drain is the current that the charger uses from the battery when the wall plug is not connected The reverse current of the MULTI US 7000 is very low and corresponds to 1 Ah per m...

Страница 14: ...ranty to the original purchaser of this product This limited warranty is not trans ferable CTEK SWEDEN AB warrants this unit for two years from the date of purchase against defect workmanship or material It is the obligation of the purchaser to forward the unit together with proof of purchase to the manufacturer or its representative with transportation cost prepaid This warranty is void if the un...

Отзывы: