14
Incidents of operation
ATTENTION : All the operations of cleaning and maintenance must be only
carried out after the complete stop of the pump and without any pipes fil-
led with liquid under pressure
PROBLEMS
CAUSES
SOLUTIONS
The pump does
not suck
Air suction
Blocked suction filter
Suction valve blocked or
broken
Control the entirety set of the suc-
tion circuit
Clean the filter
Control, clean or replace the val-
ves if necessary (A,B,C)
The pump does
not reach the
maximum pressu-
re
Rotation speed of the
pump is to low
Lance’s nozzle clogged or
damaged
Pump discharge valve
blocked or broken
Check the battery voltage
Change the nozzle
Control, clean or replace the val-
ves if necessary (D,E,F)
Pressure and ire-
gular flow
Air suction
Faulty regulator
Control the entirety set of the
suction circuit
Control the seat and the spring of
the regulator (G)
The pump does
not work and it
does not leave
water to the lance.
No power (or insufficient
supply voltage)
Check the battery voltage
The pump runs
but no water out-
put on the lance
Tank is empty
The lance is clogged
Fill the tank
Clean lance’s nozzle
Содержание MEGA 200L HP 140 BAR V5
Страница 1: ...USER MANUAL CLEANER HIGH PRESSURE Version 5...
Страница 2: ...2...
Страница 4: ...4 PERFORMANCES...
Страница 6: ...6 200L GROUP PRESENTATION...
Страница 8: ...8 HYDRAULIC DRAWING...
Страница 10: ...10 OPERATION AND MAINTENANCE...
Страница 15: ...15 Fig G Fig D Fig E Fig F Incidents of operation...
Страница 16: ...16 ANNEXES...
Страница 17: ...17 Exploded view 17 2 3 1 6 5 4 7 12 16 11 8 9 10...
Страница 19: ...19 Electric diagram 3 4 R1 A1 A2 0 V 12V 1 2 P1 M B A T B A T R1 MOT MOT...
Страница 20: ...20 Certificate of conformity...