Chapter 5. Configure via Console Port
5-10
Configure SHDSL type
This section will introduce the configuring of SHDSL type: STU-R, STU-
C-INTCLK, STU-C-EXTCLK. The default operation type is STU-R.
Select
type
and press [ENTER] or [RIGHT] to setup SHDSL type. Press
[TAB] to select the operating type and press enter to finish setting.
---------------------------------------------------
>>
type
Configure shdsl type
shdsl
Configure shdsl parameters
serial
Setup serial parameters
default
Restore factory default setting
---------------------------------------------------
Command: setup type <STU-R, STU-C-INTCLK, STU-C-EXTCLK>
Message: Please input the following information.
SHDSL operation type (TAB Select) <STU
-R>:
STU-C-INTCLK
--------------------------------------------------------
INTCLK: The device will generate the appropriate clock speed defined by
the speed setting of the interface.
EXTCLK: The device will accept the clock from the interface and will use
that clock to receive and transmit data across the interface.
Most applications use Internal Clock. If the DTE provides a clock with TX
data, the clock can set to be External Clock.