Chapter 4. Web Configuration & Operation
357
CHAPTER 4
WEB OPERATION & CONFIGURATION
Variable:
MIB object that is used to be sampled.
Sample Type:
The method of sampling the selected variable and calculating the value to be compared against the
thresholds.
Value:
The value of the statistic during the last sampling period.
Startup Alarm
: The alarm that may be triggered when this entry is first set to valid.
Rising Threshold:
If the current value is greater than the rising threshold, and the last sample value was less than this
threshold, then an alarm will be generated.
Rising Index
: The index of the event to use if an alarm is triggered by monitored variables crossing above the rising
threshold.
Falling Threshold
: If the current value is less than the falling threshold, and the last sample value was greater than this
threshold, then an alarm will be generated.
Falling Index:
The index of the event to use if an alarm is triggered by monitored variables crossing below the falling
threshold.
4.4.5.4.1.4 RMON Event Overview
Event Index:
Display the event entry index.
Log Index
: Display the log entry index.
Log Time
: Display Event log time.
Log Description:
Display Event description.
4.4.6 LACP
4.4.6.1 System Status