Chapter 4. Web Configuration & Operation
229
CHAPTER 4
WEB OPERATION & CONFIGURATION
Data Source:
Indicates the port ID which wants to be monitored.
Interval:
Indicates the polling interval. By default, 1800 seconds is specified. The allowed range is 1 - 3600 seconds.
Buckets:
The number of buckets requested for this entry. By default, 50 is specified. The allowed range is 1 - 3600.
Buckets Granted:
The number of buckets granted.
Click the “Add New Entry” button to insert a new entry to the list.
Click the “Delete” button to remove a newly-inserted entry or select the checkbox to remove a saved entry during the
next save.
Click the “Save” button to save settings or changes.
Click the “Reset” button to restore changed settings to the default settings.
4.3.4.1.8.3 RMON Alarm Configuration
RMON Alarm configuration defines specific criteria that will generate response events. It can be set to test data over
any specified time interval and can monitor absolute or changing values. Alarms can also be set to respond to rising or
falling thresholds.
ID:
Indicates the index of the entry. The range is from 1 to 65535.
Interval:
The polling interval for sampling and comparing the rising and falling threshold. The range is from 1to 2^31
seconds.
Variable:
The object number of the MIB variable to be sampled. Only variables of the type ifEntry.n.n may be sampled.
Possible variables are InOctets, InUcastPkts, InNUcastPkts, InDiscards, InErrors, InUnknownProtos, OutOctets,
OutUcastPkts, OutNUcastPkts, OutDiscards, OutErrors, and OutQLen.
Sample Type:
Test for absolute or relative change in the specified variable.
Absolute:
The variable is compared to the thresholds at the end of the sampling period.
Delta:
The last sample is subtracted from the current value and the difference is compared to the thresholds.
Value:
The statistic value during the last sampling period.
Startup Alarm:
Select a method that is used to sample the selected variable and calculate the value to be compared
against the thresholds.
Rising or Falling:
Trigger alarm when the first value is larger than the rising threshold or less than the falling
threshold.
Rising:
Trigger alarm when the first value is larger than the rising threshold.
Содержание MSW-4424C Series