M12 Cable Connector Installation

 

      Before  assembling  M12  cable,  make  sure  you  have  the 

following M12 cable connector components and cable at hand. 
 

 

 
 

Assembly Steps: 

Step 1. 

Thread the screw nut, O-ring, and housing over the cable 

in the order shown below and keep them loose in this step. 

 

 

 

 

Step 2.

 Strip the cable and the individual cores to fit the 

connector. Insert the stripped wires into the opened 

contact clamps.  

 

 

 

 
 
 
 

Step 3.

 Tighten the connector by turning clockwise, making sure 

that the wires inside the connector are not twisted as the 

screwed housing is assembled. 

 

 
 
 
 
 

 

 

 

 

 

 

Use a flat-head screwdriver to unlock and remove the device from the 

din rail when un-mounting. 

 
 
 
 
 
 
 

 

Insert the flat-head screwdriver into the indicated din rail snap level 

hole.

 

 

Push up the flat-head screwdriver to pull the din rail snap level open.

 

Figure 21: Un-mounting

 

Application

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall-Mounting and DIN Rail 

The ITP-G800M/G802SM-8PH(E)24 Series come with both wall 

mount  (standard  accessory)  and  DIN  rail  hardware  brackets 
(optional  accessory).  The  wall  mount  bracket  has  been  attached 

to  the  device.  Therefore,  there  is  no  need  to  install  wall  mount 

bracket.  
 
 

 

 

 

 

 

 

 

Figure 18: Wall mounting 

When installing the DIN rail bracket,  be  sure  to correctly align 

the  orientation  pin  (Figure  19).  The  DIN  Rail  bracket  has  a  steel 

spring in the upper rail of the bracket. This spring is compressed 

for mounting and un-mounting by applying downward force. 
 
 

 
 

 

 
 

 

Figure 19: Din rail installation 

 

 

 

 

 

 

Figure 20: Mounting 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 11 - 

Figure 15:  Thread components over the cable 

Figure 16:  Insert the stripped wires to contact clamps 

Screw Nut 

Housing 

Male Contact 
Connector 

O-Ring 

Figure 17:  Tighten the connector 

- 12 - 

www.ctcu.com 

- 13 - 

- 14 - 

Figure 22:  Onboard train application for ITP Series 

NOTES: 

Wall mounting  

holes 

Wall mounting  

holes 

 

 

 

 